5 resultados para Compressed natural gas.

em QSpace: Queen's University - Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A scenario-based two-stage stochastic programming model for gas production network planning under uncertainty is usually a large-scale nonconvex mixed-integer nonlinear programme (MINLP), which can be efficiently solved to global optimality with nonconvex generalized Benders decomposition (NGBD). This paper is concerned with the parallelization of NGBD to exploit multiple available computing resources. Three parallelization strategies are proposed, namely, naive scenario parallelization, adaptive scenario parallelization, and adaptive scenario and bounding parallelization. Case study of two industrial natural gas production network planning problems shows that, while the NGBD without parallelization is already faster than a state-of-the-art global optimization solver by an order of magnitude, the parallelization can improve the efficiency by several times on computers with multicore processors. The adaptive scenario and bounding parallelization achieves the best overall performance among the three proposed parallelization strategies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis examines two ongoing development projects that received financial support from international development organizations, and an alternative mining tax proposed by the academia. Chapter 2 explores the impact of commoditization of coffee on its export price in Ethiopia. The first part of the chapter traces how the Ethiopian’s current coffee trade system and commoditization come to be. Using regression analysis, the second part tests and confirms the hypothesis that commoditization has led to a reduction in coffee export price. Chapter 3 conducts a cost-benefit analysis on a controversial, liquefied natural gas export project in Peru that sought to export one-third of the country’s proven natural gas reserves. While the country can receive royalty and corporate income tax in the short and medium term, these benefits are dwarfed by the future costs of paying for alternative energy after gas depletion. The conclusion is robust for a variety of future energy-price and energy-demand scenarios. Chapter 4 quantifies through simulation the economic distortions of two common mining taxes, the royalty and ad-valorem tax, vis-à-vis the resource rent tax. The latter is put forward as a better mining tax instrument on account of its non-distortionary nature. The rent tax, however, necessitates additional administrative burdens and induces tax-avoidance behavior, both leading to a net loss of tax revenue. By quantifying the distortions of royalty and the ad-valorem tax, one can establish the maximum loss that can be incurred by the rent tax. Simulation results indicate that the distortion of the ad-valorem tax is quite modest. If implemented, the rent tax is likely to result in a greater loss. While the subject matters may appear diverse, they are united by one theme. These initiatives were endorsed and supported by authorities and development agencies in the aim of furthering economic development and efficiency, but they are unlikely to fulfill the goal. Lessons for international development can be learnt from successful stories as well as from unsuccessful ones.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Thermally driven liquid-desiccant air-conditioners (LDAC) are a proven but still developing technology. LDACs can use a solar thermal system to reduce the operational cost and environmental impact of the system by reducing the amount of fuel (e.g. natural gas, propane, etc.) used to drive the system. LDACs also have a key benefit of being able to store energy in the form of concentrated desiccant storage. TRNSYS simulations were used to evaluate several different methods of improving the thermal and electrical coefficients of performance (COPt and COPe) and the solar fraction (SF) of a LDAC. The study analyzed a typical June to August cooling season in Toronto, Ontario. Utilizing properly sized, high-efficiency pumps increased the COPe to 3.67, an improvement of 55%. A new design, featuring a heat recovery ventilator on the scavenging-airstream and an energy recovery ventilator on the process-airstream, increased the COPt to 0.58, an improvement of 32%. This also improved the SF slightly to 54%, an increase of 8%. A new TRNSYS TYPE was created to model a stratified desiccant storage tank. Different volumes of desiccant were tested with a range of solar array system sizes. The largest storage tank coupled with the largest solar thermal array showed improvements of 64% in SF, increasing the value to 82%. The COPe was also improved by 17% and the COPt by 9%. When combining the heat recovery systems and the desiccant storage systems, the simulation results showed a 78% increase in COPe and 30% increase in COPt. A 77% improvement in SF and a 17% increase in total cooling rate were also predicted by the simulation. The total thermal energy consumed was 10% lower and the electrical consumption was 34% lower. The amount of non-renewable energy needed from the natural gas boiler was 77% lower. Comparisons were also made between LDACs and vapour-compression (VC) systems. Dependent on set-up, LDACs provided higher latent cooling rates and reduced electrical power consumption. Negatively, a thermal input was required for the LDAC systems but not for the VC systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Photovoltaic (PV) systems offer a way to generate electricity locally in an urban setting while avoiding the environmental impacts of more widely used energy sources such as oil, coal, nuclear and natural gas. This report attempts to measure the benefits of incorporating solar technologies into urban residential land uses and identifies challenges to their widespread use by comparing implementation among three distinct residential neighbourhoods common to Canadian cities. The City of Kingston, Ontario is used as the location for this study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Greenhouses have become an invaluable source of year-round food production. Further development of viable and efficient high performance greenhouses is important for future food security. Closing the greenhouse envelope from the environment can provide benefits in space heating energy savings, pest control, and CO2 enrichment. This requires the application of a novel air conditioning system to handle the high cooling loads experienced by a greenhouse. Liquid desiccant air-conditioning (LDAC) have been found to provide high latent cooling capacities, which is perfect for the application of a humid greenhouse microclimate. TRNSYS simulations were undertaken to study the feasibility of two liquid desiccant dehumidification systems based on their capacity to control the greenhouse microclimate, and their cooling performance. The base model (B-LDAC) included a natural gas boiler, and two cooling systems for seasonal operation. The second model (HP-LDAC) was a hybrid liquid desiccant-heat pump dehumidification system. The average tCOPdehum and tCOPtotal of the B-LDAC system increased from 0.40 and 0.56 in January to 0.94 and 1.09 in June. Increased load and performance during a sample summer day improved these values to 3.5 and 3.0, respectively. The average eCOPdehum and eCOPtotal values were 1.0 and 1.8 in winter, and 1.7 and 2.1 in summer. The HP-LDAC system produced similar daily performance trends where the annual average eCOPdehum and eCOPtotal values were 1.3 and 1.2, but the sample day saw peaks of 2.4 and 3.2, respectively. The B-LDAC and HP-LDAC results predicted greenhouse temperatures exceeding 30°C for 34% and 17% of the month of July, respectively. Similarly, humidity levels increased in summer months, with a maximum of 14% of the time spent over 80% in May for both models. The percentage of annual savings in space heating energy associated with closing the greenhouse to ventilation was 34%. The additional annual regeneration energy input was reduced by 26% to 526 kWhm-2, with the implementation of a heat recovery ventilator on the regeneration exhaust air. The models also predicted an electrical energy input of 245 kWhm-2 and 305 kWhm-2 for the B-LDAC and HP-LDAC simulations, respectively.