2 resultados para Attrition Game-1 sensitivity studies.

em QSpace: Queen's University - Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The control of radioactive backgrounds will be key in the search for neutrinoless double beta decay at the SNO+ experiment. Several aspects of the SNO+ back- grounds have been studied. The SNO+ tellurium purification process may require ultra low background ethanol as a reagent. A low background assay technique for ethanol was developed and used to identify a source of ethanol with measured 238U and 232Th concentrations below 2.8 10^-13 g/g and 10^-14 g/g respectively. It was also determined that at least 99:997% of the ethanol can be removed from the purified tellurium using forced air ow in order to reduce 14C contamination. In addition, a quality-control technique using an oxygen sensor was studied to monitor 222Rn contamination due to air leaking into the SNO+ scintillator during transport. The expected sensitivity of the technique is 0.1mBq/L or better depending on the oxygen sensor used. Finally, the dependence of SNO+ neutrinoless double beta decay sensitivity on internal background levels was studied using Monte Carlo simulation. The half-life limit to neutrinoless double beta decay of 130Te after 3 years of operation was found to be 4.8 1025 years under default conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Clinical optical motion capture allows us to obtain kinematic and kinetic outcome measures that aid clinicians in diagnosing and treating different pathologies affecting healthy gait. The long term aim for gait centres is for subject-specific analyses that can predict, prevent, or reverse the effects of pathologies through gait retraining. To track the body, anatomical segment coordinate systems are commonly created by applying markers to the surface of the skin over specific, bony anatomy that is manually palpated. The location and placement of these markers is subjective and precision errors of up to 25mm have been reported [1]. Additionally, the selection of which anatomical landmarks to use in segment models can result in large angular differences; for example angular differences in the trunk can range up to 53o for the same motion depending on marker placement [2]. These errors can result in erroneous kinematic outcomes that either diminish or increase the apparent effects of a treatment or pathology compared to healthy data. Our goal was to improve the accuracy and precision of optical motion capture outcome measures. This thesis describes two separate studies. In the first study we aimed to establish an approach that would allow us to independently quantify the error among trunk models. Using this approach we determined if there was a best model to accurately track trunk motion. In the second study we designed a device to improve precision for test, re-test protocols that would also reduce the set-up time for motion capture experiments. Our method to compare a kinematically derived centre of mass velocity to one that was derived kinetically was successful in quantifying error among trunk models. Our findings indicate that models that use lateral shoulder markers as well as limit the translational degrees of freedom of the trunk through shared pelvic markers result in the least amount of error for the tasks we studied. We also successfully reduced intra- and inter-operator anatomical marker placement errors using a marker alignment device. The improved accuracy and precision resulting from the methods established in this thesis may lead to increased sensitivity to changes in kinematics, and ultimately result in more consistent treatment outcomes.