12 resultados para Gas chromatography

em Plymouth Marine Science Electronic Archive (PlyMSEA)


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A number of chlorinated and brominated low molecular weight hydrocarbons (halocarbons) have been measured in and adjacent to the North Sea estuaries of the Humber and the Rhine. The measurements have been carried out using a newly constructed purge-and-trap sample work-up system coupled to megabore gas chromatography with electron capture detection. The results show that whereas the Humber is a pronounced source of the anthropogenic halocarbons carbon tetrachloride and perchloroethylene, the input from the Rhine into the North Sea of these compounds is more modest. Some halocarbons normally considered as mainly or even exclusively of natural origin are released from the two investigated estuaries into the North Sea. A distinct patch of high concentrations of the naturally produced compound bromoform was observed in the southwestern North Sea. The results have also been used to examine some of the halocarbons for common sources.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A procedure for estimating total organochlorine pesticide and PCB residue in seal blubber at concentrations of greater than 1μg g-1 of lipid is described. Lipid is cleaned up by alumina column chromatography, and the halogen concentration of the resulting hexane eluace is determined by combustion and microcoulometry. Results are similar to those obtained by gas chromatographic analysis and can be used to interpolate between results so obtained when data on specific organochlorine compounds is not required for each sample. The organochlorine residues recovered in this manner did not constitute all the halogen determined by combustion and microcoulometry of seal lipid. Analysis by the total halogen procedure was 2.5 tunes faster than the rate achieved with a combination of liquid and gas chromatography operated manually; the requirements for laboratory equipment and space for sample preparation are reduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The role of the ocean in the cycling of oxygenated volatile organic compounds (OVOCs) remains largely unanswered due to a paucity of datasets. We describe the method development of a membrane inlet-proton transfer reaction/mass spectrometer (MI-PTR/MS) as an efficient method of analysing methanol, acetaldehyde and acetone in seawater. Validation of the technique with water standards shows that the optimised responses are linear and reproducible. Limits of detection are 27 nM for methanol, 0.7 nM for acetaldehyde and 0.3 nM for acetone. Acetone and acetaldehyde concentrations generated by MI-PTR/MS are compared to a second, independent method based on purge and trap-gas chromatography/flame ionisation detection (P&T-GC/FID) and show excellent agreement. Chromatographic separation of isomeric species acetone and propanal permits correction to mass 59 signal generated by the PTR/MS and overcomes a known uncertainty in reporting acetone concentrations via mass spectrometry. A third bioassay technique using radiolabelled acetone further supported the result generated by this method. We present the development and optimisation of the MI-PTR/MS technique as a reliable and convenient tool for analysing seawater samples for these trace gases. We compare this method with other analytical techniques and discuss its potential use in improving the current understanding of the cycling of oceanic OVOCs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sampling and analytical system has been developed for shipboard measurements of high-resolution vertical profiles of the marine trace gas dimethylsulfide (DMS). The system consists of a tube attached to a CTD with a peristaltic pump on deck that delivers seawater to a membrane equilibrator and atmospheric pressure chemical ionization mass spectrometer (Eq-APCIMS). This allows profiling DMS concentrations to a depth of 50 m, with a depth resolution of 1.3-2 m and a detection limit of nearly 0.1 nmol L-1. The seawater is also plumbed to allow parallel operation of additional continuous instruments, and simultaneous collection of discrete samples for complementary analyses. A valve alternates delivery of seawater from the vertical profiler and the ship�s underway intake, thereby providing high-resolution measurements in both the vertical and horizontal dimensions. Tests conducted on various cruises in the Mediterranean Sea, Atlantic, Indian, and Pacific Oceans show good agreement between the Eq-APCIMS measurements and purge and trap gas chromatography with flame photometric detection (GC-FPD) and demonstrate that the delivery of seawater from the underway pump did not significantly affect endogenous DMS concentrations. Combination of the continuous flow DMS analysis with high-frequency hydrographic, optical, biological and meteorological measurements will greatly improve the spatial/temporal resolution of seagoing measurements and improve our understanding of DMS cycling.