Undulating Oceanographic Recorders (UORs) and Continuous Plankton Recorders (CPRs) equipped with a suite of sensors were towed by merchant vessels in the North Sea between 1988 and 1991, recording a range of environmental variables. These were used to interpret the results of analyses of the plankton taken on CPR tows off the northeast coast of the UK in 1989 and in the Skagerrak and Kattegat in July 1988 and through 1989. Correlations were found between the biota and the environmental variables. The tidal front off the northeast coast of the UK and the front between the low salinity water in the Kattegat and the higher salinity water in the Skagerrak were dominant factors correlating with the distribution of the plankton assemblages. Discontinuities, defining the positions of the fronts, in the values of physical variables (temperature and, where measured, salinity and turbidity) were closely identified with geographical divisions between plankton assemblages. Measures of irradiance were found to be important on several occasions, presumably due to diel migrations of the zooplankton.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The beam attenuation serves as a proxy for particulate matter and is a key parameter in visibility algorithms for the aquatic environment. It is well known, however, that the beam attenuation is a function of the acceptance angle of the transmissometer used to measure it. Here we compare eight different transmissometers with four different acceptance angles using four different deployment strategies and sites, and find that their mean attenuation values differ markedly and in a consistent way with instrument acceptance angle: smaller acceptance angles provide higher beam attenuation values. This difference is due to variations in scattered light collected with different acceptance angles and is neither constant nor easy to parameterize. Variability (in space or time) in the ratios of beam attenuations measured by two different instruments correlates, in most cases, with the particle size parameter (as expected from Mie theory), but this correlation is often weak and can be the opposite of expectations based on particle size changes. We recommended careful consideration of acceptance angle in applications of beam transmission data especially when comparing data from different instruments. (C) 2009 Optical Society of America