8 resultados para Aqueous polymeric coatings

em Plymouth Marine Science Electronic Archive (PlyMSEA)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some advantages of a new dielectric detector, CR-39, are described in relation to the analysis of concentrations and distributions of α-particle emitters from a variety of materials. The detector provides an economic and versatile approach to many problems and complements conventional methods of analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sampling and analytical system has been developed for shipboard measurements of high-resolution vertical profiles of the marine trace gas dimethylsulfide (DMS). The system consists of a tube attached to a CTD with a peristaltic pump on deck that delivers seawater to a membrane equilibrator and atmospheric pressure chemical ionization mass spectrometer (Eq-APCIMS). This allows profiling DMS concentrations to a depth of 50 m, with a depth resolution of 1.3-2 m and a detection limit of nearly 0.1 nmol L-1. The seawater is also plumbed to allow parallel operation of additional continuous instruments, and simultaneous collection of discrete samples for complementary analyses. A valve alternates delivery of seawater from the vertical profiler and the ship�s underway intake, thereby providing high-resolution measurements in both the vertical and horizontal dimensions. Tests conducted on various cruises in the Mediterranean Sea, Atlantic, Indian, and Pacific Oceans show good agreement between the Eq-APCIMS measurements and purge and trap gas chromatography with flame photometric detection (GC-FPD) and demonstrate that the delivery of seawater from the underway pump did not significantly affect endogenous DMS concentrations. Combination of the continuous flow DMS analysis with high-frequency hydrographic, optical, biological and meteorological measurements will greatly improve the spatial/temporal resolution of seagoing measurements and improve our understanding of DMS cycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diatom biofilms are abundant in the marine environment. It is assumed (but untested) that extracellular polymeric substances(EPS), produced by diatoms, enable cells to cope with fluctuating salinity. To determine the protective role of EPS, Cylindrotheca closterium was grown in xanthan gum at salinities of 35, 50, 70 and 90 ppt. A xanthan matrix significantly increased cell viability (determined by SYTOX-Green), growth rate and population density by up to 300, 2, 300 and 200%, respectively. Diatoms grown in 0.75% w/v xanthan, subjected to acute salinity shock treatments (at salinities 17.5, 50, 70 and 90 ppt) maintained photosynthetic capacity, Fq′/Fm′, within 4% of pre-shock values, whereas Fq′/Fm′ in cells grown without xanthan declined by up to 64% with hypersaline shock. Biofilms that developed in xanthan at standard salinity helped cells to maintain function during salinity shock. These results provide evidence of the benefits of living in an EPS matrix for biofilm diatoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An interlaboratory comparison (ILC) was conducted to evaluate the proficiency of multiple laboratories to quantify dimethylsulfide (DMS) in aqueous solution. Ten participating laboratories were each supplied with blind duplicate test solutions containing dimethylsulfoniopropionate hydrochloride (DMSP HCl) dissolved in acidified artificial seawater. The test solutions were prepared by the coordinating laboratory from a DMSP HCl reference material that was synthesized and purity certified for this purpose. A concentration range was specified for the test solutions and the participating laboratories were requested to dilute them as required for their analytical procedure, together with the addition of excess alkali under gas-tight conditions to convert the DMSP to DMS. Twenty-two DMS concentrations and their estimated expanded measurement uncertainties (95% confidence level) were received from the laboratories. With two exceptions, the within-laboratory variability was 5% or less and the between-laboratory variability was ~ 25%. The magnitude of expanded measurement uncertainties reported from all participants ranged from 1% to 33% relative to the result. The information gained from this pilot ILC indicated the need for further test sample distribution studies of this type so that participating laboratories can identify systematic errors in their analysis procedures and realistically evaluate their measurement uncertainty. The outcome of ILC studies provides insights into the comparability of data in the global surface seawater DMS database.