4 resultados para submaximal isometric voluntary contraction

em Greenwich Academic Literature Archive - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semi-Lagrangian finite volume scheme for solving viscoelastic flow problems is presented. A staggered grid arrangement is used in which the dependent variables are located at different mesh points in the computational domain. The convection terms in the momentum and constitutive equations are treated using a semi-Lagrangian approach in which particles on a regular grid are traced backwards over a single time-step. The method is applied to the 4 : 1 planar contraction problem for an Oldroyd B fluid for both creeping and inertial flow conditions. The development of vortex behaviour with increasing values of We is analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new finite volume method for solving the incompressible Navier--Stokes equations is presented. The main features of this method are the location of the velocity components and pressure on different staggered grids and a semi-Lagrangian method for the treatment of convection. An interpolation procedure based on area-weighting is used for the convection part of the computation. The method is applied to flow through a constricted channel, and results are obtained for Reynolds numbers, based on half the flow rate, up to 1000. The behavior of the vortex in the salient corner is investigated qualitatively and quantitatively, and excellent agreement is found with the numerical results of Dennis and Smith [Proc. Roy. Soc. London A, 372 (1980), pp. 393-414] and the asymptotic theory of Smith [J. Fluid Mech., 90 (1979), pp. 725-754].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the effects of cadence and power output on physiological and biomechanical responses to incremental arm-crank ergometry (ACE). Ten male subjects (mean +/- SD age, 30.4 +/-5.4 y; height, 1.78 +/-0.07 m; mass, 86.1 +/-14.2 kg) undertook 3 incremental ACE protocols to determine peak oxygen uptake (VO2 peak; mean of 3 tests: 3.07 +/- 0.17 L.min-1) at randomly assigned cadences of 50, 70, or 90 r.min-1. Heart rate and expired air were continually monitored. Central (RPE-C) and local (RPE-L) ratings of perceived exertion were recorded at volitional exhaustion. Joint angles and trunk rotation were analysed during each exercise stage. During submaximal power outputs of 50, 70, and 90 W, oxygen consumption (VO2) was lowest for 50 r.min-1 and highest for 90 r.min-1 (p < 0.01). VO2 peak was lowest during 50 r.min-1 (2.79 +/-0.45 L.min-1; p < 0.05) when compared with both 70 r.min-1 and 90 r.min-1 (3.16 +/-0.58, 3.24 +/-0.49 L.min-1, respectively; p > 0.05). The difference between RPE-L and RPE-C at volitional exhaustion was greatest during 50 r.min-1 (2.9 +/- 1.6) when compared with 90 r.min-1 (0.9 +/- 1.9, p < 0.05). At VO2 peak, shoulder range of motion (ROM) and trunk rotation were greater for 50 and 70 r.min-1 when compared with 90 r.min-1 (p < 0.05). During submaximal power outputs, shoulder angle and trunk rotation were greatest at 50 r.min-1 when compared with 90 r.min-1 (p < 0.05). VO2 was inversely related to both trunk rotation and shoulder ROM during submaximal power outputs. The results of this study suggest that the greater forces required at lower cadences to produce a given power output resulted in greater joint angles and range of shoulder and trunk movement. Greater isometric contractions for torso stabilization and increased cost of breathing possibly from respiratory-locomotor coupling may have contributed increased oxygen consumption at higher cadences.