There are many factors in mucosal secretions that contribute to innate immunity and the 'first line of defence' at mucosal surfaces. Few studies, however, have investigated the effects of exercise on many of these 'defence' factors. The aim of the present study was to determine the acute effects of prolonged exercise on salivary levels of selected antimicrobial peptides (AMP) that have not yet been studied in response to exercise (HNP1-3 and LL-37) in addition to immunoglobulin A (IgA). A secondary objective was to assess the effects of exercise on saliva antibacterial capacity. Twelve active men exercised on a cycle ergometer for 2.5 h at approximately 60% of maximal oxygen uptake. Unstimulated whole saliva samples were obtained before and after exercise. There was a significant decrease (P < 0.05) in salivary IgA:osmolality ratio, following exercise, but IgA concentration and secretion rate were unaltered. Salivary HNP1-3 and LL-37 concentrations (P < 0.01 and P < 0.05, respectively), concentration:osmolality ratios (P < 0.01) and secretion rates (P < 0.01) all increased following exercise. Salivary antibacterial capacity (against E. coli) did not change. The increased concentration of AMPs in saliva may confer some benefit to the 'first line of defence' and could result from synergistic compensation within the mucosal immune system and/or airway inflammation and epithelial damage. Further study is required to determine the significance of such changes on the overall 'defence' capacity of saliva and how this influences the overall risk for infection.
Resumo:
Exercise can have deleterious effects on the secretion of salivary immunoglobulin A (s-IgA), which appears to be related to perturbations in sympatheticoadrenal activation (Teeuw et al., 2004). Caffeine, commonly used for its ergogenic properties is associated with increased sympathetic nervous system activity, and it has been previously shown that caffeine ingestion before intensive cycling enhances s-IgA responses during exercise (Bishop et al., 2006). Therefore, the aim of the present study was to examine the effect of a performance cereal bar, containing caffeine, before and during prolonged exhaustive cycling on exercise performance and the salivary secretion of IgA, alpha-amylase activity and cortisol. Using a randomised cross-over design and following a 10 – 12 hour overnight fast, 12 trained cyclists, mean (SEM) age: 21(1) yr; height: 179(2) cm; body mass: 73.6(2.5) kg; maximal oxygen uptake, VO2max: 57.9(1.2) completed 2.5 h of cycling at 60%VO2max (with regular water ingestion) on a stationary ergometer, which was followed by a ride to exhaustion at 75% VO2max. Immediately before exercise, and after 55 min and 115 min of exercise participants ingested a 0.9 MJ cereal bar containing 45 g carbohydrate, 5 g protein, 3 g fat and 100 mg of caffeine (CAF) or an isocaloric noncaffeine bar (PLA). Unstimulated timed saliva samples were collected immediately before exercise, after 70 min and 130 min of exercise, and immediately after the exhaustive exercise bout. Saliva was analysed for s-IgA, alpha-amylase activity and cortisol concentration. Saliva flow rates were determined to calculate the s-IgA secretion rate. Data were analysed using a 2-way repeated measures ANOVA and post-hoc t-tests with Holm Bonferroni adjustments applied where appropriate. Time to exhaustion was 35% longer in CAF compared with PLA ((2177 (0.2) vs 1615 (0.16) s; P < 0.05)). Saliva flow rate did not change significantly during the exercise protocol. Exercise was associated with elevations in s-IgA concentration (9% increase), s-IgA secretion rate (24% increase) and alpha-amylase activity (224% increase) post-exhaustion (P < 0.01), but there was no effect of CAF on these responses. Salivary cortisol concentration increased by 64% post-exhaustion in the CAF trial only (P < 0.05), indicating an increase in adrenal activity following caffeine ingestion. Values were 35.7 (5.5) and 19.6 (3.4) nmol/L post-exhaustion for CAF and PLA, respectively. These findings show that ingestion of a caffeine containing cereal bar during prolonged exhaustive cycling enhances endurance performance, increases salivary cortisol secretion post-exhaustion, but does not affect the exercise-induced increases in s-IgA or alpha-amylase activity.
Resumo:
This study investigated the effect of a fed or fasted state on the salivary immunoglobulin A (s-IgA) response to prolonged cycling. Using a randomized, crossover design, 16 active adults (8 men and 8 women) performed 2 hr of cycling on a stationary ergometer at 65% of maximal oxygen uptake on 1 occasion after an overnight fast (FAST) and on another occasion 2 hr after consuming a 2.2-MJ high-carbohydrate meal (FED). Timed, unstimulated whole saliva samples were collected immediately before ingestion of the meal, immediately preexercise, 5 min before cessation of exercise, immediately postexercise, and 1 hr postexercise. The samples were analyzed for s-IgA concentration, osmolality, and cortisol, and saliva flow rates were determined to calculate s-IgA secretion rate. Saliva flow rate decreased by 50% during exercise (p < .05), and s-IgA concentration increased by 42% (p < .05), but s-IgA secretion rate remained unchanged. There was a 37% reduction in s-IgA:osmolality postexercise (p < .05), and salivary cortisol increased by 68% (p < .05). There was no effect of FED vs. FAST on these salivary responses. The s-IgA concentration, secretion rate, and osmolality were found to be significantly lower in women than in men throughout the exercise protocol (p < .05); however, there was no difference between genders in saliva flow rate, s-IgA:osmolality ratio, or cortisol. These data demonstrate that a fed or fasted state 2 hr before exercise does not influence resting s-IgA or the response to prolonged cycling. Furthermore, these results show lower levels of s-IgA and osmolality in women than in men at rest.
Effects of exercise intensity on salivary antimicrobial proteins and markers of stress in active men
Resumo:
In the present study, we assessed the effects of exercise intensity on salivary immunoglobulin A (s-IgA) and salivary lysozyme (s-Lys) and examined how these responses were associated with salivary markers of adrenal activation. Using a randomized design, 10 healthy active men participated in three experimental cycling trials: 50% maximal oxygen uptake (VO2max), 75%VO2max, and an incremental test to exhaustion. The durations of the trials were the same as for a preliminary incremental test to exhaustion (22.3 min, sx = 0.8). Timed, unstimulated saliva samples were collected before exercise, immediately after exercise, and 1 h after exercise. In the incremental exhaustion trial, the secretion rates of both s-IgA and s-Lys were increased. An increase in s-Lys secretion rate was also observed at 75%VO2max. No significant changes in saliva flow rate were observed in any trial. Cycling at 75%VOmax and to exhaustion increased the secretion of alpha-amylase and chromogranin A immediately after exercise; higher cortisol values at 75%VO2max and in the incremental exhaustion trial compared with 50%VO2max were observed 1 h immediately after exercise only. These findings suggest that short-duration, high-intensity exercise increases the secretion rate of s-IgA and s-Lys despite no change in the saliva flow rate. These effects appear to be associated with changes in sympathetic activity and not the hypothalamic - pituitary - adrenal axis.
Resumo:
While incidents requiring the rapid egress of passengers from trains are infrequent, perhaps the most challenging scenario for passengers involves the evacuation from an overturned carriage subjected to fire. In this paper we attempt to estimate the flow rate capacity of an overturned rail carriage end exit. This was achieved through two full-scale evacuation experiments, in one of which the participants were subjected to non-toxic smoke. The experiments were conducted as part of a pilot study into evacuation from rail carriages. In reviewing the experimental results, it should be noted that only a single run of each trial was undertaken with a limited — though varied — population. As a result it is not possible to test the statistical significance of the evacuation times quoted and so the results should be treated as indicative rather than definitive. The carriage used in the experiments was a standard class Mark IID which, while an old carriage design, shares many features with those carriages commonly found on the British rail network. In the evacuation involving smoke, the carriage end exit was found to achieve an average flow rate capacity of approximately 5.0 persons/min. The average flow rate capacity of the exit without smoke was found to be approximately 9.2 persons/min. It was noted that the presence of smoke tended to reduce significantly the exit flow rate. Due to the nature of the experimental conditions, these flow rates are considered optimistic. Finally, the authors make several recommendations for improving survivability in rail accidents. Copyright © 2000 John Wiley & Sons, Ltd.
Resumo:
In order to find a link between results obtained from a laboratory erosion tester and tests carried out on a pneumatic conveyor, a comparison has been made between weight loss from bends on an industrial-scale pneumatic conveyor and erosion rates obtained in a small centrifugal erosion tester, for the same materials. Identical test conditions have been applied to both experiments so that comparable test results have been obtained. The erosion rate of mild steel commonly used as the wall material of conveyor pipes and pipe bends was determined individually on both test rigs. A relationship between weight loss from the bends and erosion rate determined from the tester has been developed. A discussion based on the results and their applicability to the prediction of wear in pneumatic conveyors concludes the paper.
Resumo:
Particle concentration is known as a main factor that affects erosion rate of pipe bends in pneumatic conveyors. With consideration of different bend radii, the effect of particle concentration on weight loss of mild steel bends has been investigated in an industrial scale test rig. Experimental results show that there was a significant reduction of the specific erosion rate for high particle concentrations. This reduction was considered to be as a result of the shielding effect during the particle impacts. An empirical model is given. Also a theoretical study of scaling on the shielding effect, and comparisons with some existing models, are presented. It is found that the reduction in specific erosion rate (relative to particle concentration) has a stronger relationship in conveying pipelines than has been found in the erosion tester.
Resumo:
The dissolution of thin film under-bump-metallization (UBM) by molten solder has been one of the most serious processing problems in electronic packaging technology. Due to a higher melting temperature and a greater Sn content, a molten lead-free solder such as eutectic SnAg has a faster dissolution rate of thin film UBM than the eutectic SnPb. The work presented in this paper focuses on the role of 0.5 wt % Cu in the base Sn–3.5%Ag solder to reduce the dissolution of the Cu bond pad in ball grid array applications. We found that after 0.5 wt % Cu addition, the rate of dissolution of Cu in the molten Sn–3.5%Ag solder slows down dramatically. Systematic experimental work was carried out to understand the dissolution behavior of Cu by the molten Sn–3.5%Ag and Sn–3.5%Ag–0.5%Cu solders at 230–250 °C, for different time periods ranging from 1 to 10 min. From the curves of consumed Cu thickness, it was concluded that 0.5 wt % Cu addition actually reduces the concentration gradient at the Cu metallization/molten solder interface which reduces the driving force of dissolution. During the dissolution, excess Cu was found to precipitate out due to heterogeneous nucleation and growth of Cu6Sn5 at the solder melt/oxide interface. In turn, more Cu can be dissolved again. This process continues with time and leads to more dissolution of Cu from the bond pad than the amount expected from the solubility limit, but it occurs at a slower rate for the molten Sn–3.5%Ag–0.5%Cu solder. © 2003 American Institute of Physics.
Resumo:
It has been shown that remote monitoring of pulmonary activity can be achieved using ultra-wideband (UWB) systems, which shows promise in home healthcare, rescue, and security applications. In this paper, we first present a multi-ray propagation model for UWB signal, which is traveling through the human thorax and is reflected on the air/dry-skin/fat/muscle interfaces. A geometry-based statistical channel model is then developed for simulating the reception of UWB signals in the indoor propagation environment. This model enables replication of time-varying multipath profiles due to the displacement of a human chest. Subsequently, a UWB distributed cognitive radar system (UWB-DCRS) is developed for the robust detection of chest cavity motion and the accurate estimation of respiration rate. The analytical framework can serve as a basis in the planning and evaluation of future measurement programs. We also provide a case study on how the antenna beamwidth affects the estimation of respiration rate based on the proposed propagation models and system architecture
Resumo:
A communication system model for mutual information performance analysis of multiple-symbol differential M-phase shift keying over time-correlated, time-varying flat-fading communication channels is developed. This model is a finite-state Markov (FSM) equivalent channel representing the cascade of the differential encoder, FSM channel model and differential decoder. A state-space approach is used to model channel phase time correlations. The equivalent model falls in a class that facilitates the use of the forward backward algorithm, enabling the important information theoretic results to be evaluated. Using such a model, one is able to calculate mutual information for differential detection over time-varying fading channels with an essentially finite time set of correlations, including the Clarke fading channel. Using the equivalent channel, it is proved and corroborated by simulations that multiple-symbol differential detection preserves the channel information capacity when the observation interval approaches infinity.