8 resultados para powder redispersion

em Greenwich Academic Literature Archive - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metal powder in the range of 10-100 microns is widely employed in the production of Raney nickel type catalysts for hydrogenation reactions and hydrogen fuel cell manufacture. In this presentation we examine the modelling of powder production in a gas atomisation vessel using CFD techniques. In a fully coupled Lagrangian-Eulerian two phase scheme, liquid meal particles are tracked through the vessel following atomisation of a liquid nickel-aluminium stream. There is full momentum, heat and turbulence transport between particles and surrounding argon gas and the model predicts the position of solidification depending on particle size and undercooled condition. Maps of collision probability of particles at different stages of solidification are computed, to predict the creation of satellite defects, or to initiate solidification of undercooled droplets. The model is used to support experimental work conducted under the ESA/EU project IMPRESS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new experimental procedure has been implemented and a prototype of a novel adhesion tester has been designed and constructed using rapid prototyping technology. A tumbler mixer has been designed and constructed for coating powder material onto a crisp substrate. In the impact separation experiment, the amount of powder detached from one side of a crisp substrate by the effect of impact forces (48g, 77g, 102g) generated by the tester was measured. Salt particles with different size fractions (63-125, 125-180, and 180-250m) and several flavoring powders have been tested extensively. By plotting the detachment versus impact force, the difference obtained between adhesion strength of different flavoring powders (which is a strong function of particle size and surface oil content of the crisp) has been discussed. The detachment rate of salt particles increased (from 1% to 2%) with particle size (from 63 to 250m) in the presence of oil on the surface of the crisp substrate and decreased rapidly with the increase in the amount of oil applied (from 0 to 1%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[No abstract is available for this article.]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: A novel methodology has been introduced to effectively coat intravascular stents with sirolimus-loaded polymeric microparticles. Methods: Dry powders of the microparticulate formulation, consisting of non-erodible polymers, were produced by a supercritical, aerosol, solvent extraction system (ASES). A design of experiment (DOE) approach was conducted on the independent variables, such as organic/CO2 phase volume ratio, polymer weight and stirring-rate, while regression analysis was utilized to interpret the influence of all operational parameters on the dependent variable of particle size. The dry powders, so formed, entered an electric field created by corona charging and were sprayed on the earthed metal stent. Furthermore, the thermal stability of sirolimus was investigated to define the optimum conditions for fusion to the metal surfaces. Results: The electrostatic dry powder deposition technology (EDPDT) was used on the metal strut followed by fusion to produce uniform, reproducible and accurate coatings. The coated stents exhibited sustained release profiles over 25 days, similar to commercial products. EDPDT-coated stents displayed significant reduced platelet adhesion. Conclusions: EDPDT appeared to be a robust accurate and reproducible technology to coat eluting stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study the impact of powder flow properties on dosator filling systems, with particular focus on improvements in dose weight accuracy and repeatability. Method: This study evaluates a range of critical powder flow properties such as: flow function, cohesion, wall friction, adhesion to wall surfaces, density/compressibility data, stress ratio “K” and gas permeability. The characterisations of the powders considered in this study were undertaken using an annular shear cell using a sample size of 0.5 litres. This tester also incorporated the facility to measure bed expansion during shear in addition to contraction under consolidation forces. A modified Jenike type linear wall friction tester was used to develop the failure loci for the powder sample in conjunction with multiple wall samples (representing a variety of material types and surface finishes). Measurements of the ratio of applied normal stress versus lateral stress were determined using a piece of test equipment specifically designed for the purpose. Results: The correct characterisation of powders and the incorporation of this data into the design of process equipment are recognised as critical for reliable and accurate operation. An example of one aspect of this work is the stress ratio “K”. This characteristic is not well understood or correctly interpreted in many cases – despite its importance. Fig 1 [Omitted] (illustrates a sample of test data. The slope of the line gives the stress ratio in a uniaxial compaction system – indicating the behaviour of the material under compaction during dosing processes. Conclusions: A correct assessment of the bulk powder properties for a given formulation can allow prediction of: cavity filling behaviour (and hence dosage), efficiency of release from dosator, and strength and stability of extruded dose en route to capsule filling Influences over the effectiveness of dosator systems have been shown to be impacted upon by: bed pre-compaction history, gas permeability in the bed (with respect to local density effects), and friction effects for materials of construction for dosators

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dosators and other dosing mechanisms operating on generally similar principles are very widely used in the pharmaceutical industry for capsule filling, and for dosing products that are delivered to the customer in powder form such as inhalers. This is a trend that is set to increase. However a significant problem for this technology is being able to predict how accurately and reliably, new drug formulations will be dosed from these machines prior to manufacture. This paper presents a review of the literature relating to powder dosators which considers mathematical models for predicting dosator performance, the effects of the dosator geometry and machine settings on the accuracy of the dose weight. An overview of a model based on classical powder mechanics theory that has been developed at The University of Greenwich is presented. The model uses inputs from a range of powder characterisation tests including, wall friction, bulk density, stress ratio and permeability. To validate the model it is anticipated that it will be trialled for a range of powders alongside a single shot dosator test rig.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The firm adhesion of flavouring particles onto crisp surfaces during coating processes is a major concern in the snack production industry. Detachment of flavouring powders from products during handling and production stages can lead to substantial financial losses for the industry, in terms of variable flavour performance and extended cleaning down time of fugitive particle build-up on process equipment. Understanding the adhesion strength of applied bulk particulates used for flavouring formulations will help analysts to evaluate the efficiency of coating processes and potentially enable them to assess the adhesion strength of newly formulated flavouring powder prior to commitment to full scale plant trials. A rapid prototype of a novel adhesion tester has been designed and constructed. The apparatus operates according to the principle of impact force acting on particles attached to the surface of the food substrate. The main component is a circular plate to which four sample holders are attached and which is subjected to vertical travel down a guide shaft. Several flavouring powders have been tested extensively. By plotting the detachment versus impact force, the difference obtained between adhesion strength of different flavouring powders (which is a strong function of particle size) has been discussed.