2 resultados para plasma sterilization
em Greenwich Academic Literature Archive - UK
Resumo:
This paper presents an analysis of biofluid behavior in a T-shaped microchannel device and a design optimization for improved biofluid performance in terms of particle liquid separation. The biofluid is modeled with single phase shear rate non-Newtonian flow with blood property. The separation of red blood cell from plasma is evident based on biofluid distribution in the microchannels against various relevant effects and findings, including Zweifach-Fung bifurcation law, Fahraeus effect, Fahraeus-Lindqvist effect and cell free phenomenon. The modeling with the initial device shows that this T-microchannel device can separate red blood cell from plasma but the separation efficiency among different bifurcations varies largely. In accordance with the imbalanced performance, a design optimization is conducted. This includes implementing a series of simulations to investigate the effect of the lengths of the main and branch channels to biofluid behavior and searching an improved design with optimal separation performance. It is found that changing relative lengths of branch channels is effective to both uniformity of flow rate ratio among bifurcations and reduction of difference of the flow velocities between the branch channels, whereas extending the length of the main channel from bifurcation region is only effective for uniformity of flow rate ratio.
Resumo:
Major and trace elemental composition provides a powerful basis for forensic comparison of soils, sediments and rocks. However, it is important that the potential 'errors' associated with the procedures are fully understood and quantified, and that standard protocols are applied for sample preparation and analysis. This paper describes such a standard procedure and reports results both for instrumental measurement precision (repeatability) and overall 'method' precision (reproducibility). Results obtained both for certified reference materials and example soils show that the instrumental measurement precision (defined by the coefficient of variation, CV) for most elements is better than 2-3%. When different solutions were prepared from the same sample powder, and from different sub-sample powders prepared from the same parent sample, the CV increased to c. 5-6% for many elements. The largest variation was found in results for certified reference materials generated from 23 instrument runs over an 18 month period (mean CV=c. 11%). Some elements were more variable than others. W was found to be the most variable and the elements V, Cr, Co, Cu, Ni and Pb also showed higher than average variability. SiO2, CaO, Al2O3 and Fe2O3, Rb, Sr, La, Ce, Nd and Sm generally showed lower than average variability, and therefore provided the most reliable basis for inter-sample comparison. It is recommended that, whenever possible, samples relating to the same investigation should be analysed in the same sample run, or at least sequential runs.