8 resultados para network theory and analysis

em Greenwich Academic Literature Archive - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is no abstract for this record.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents data relating to occupant pre-evacuation times from university and hospital outpatient facilities. Although the two occupancies are entirely different, they do employ relatively similar procedures: members of staff sweep areas to encourage individuals to evacuate.However the manner in which the dependent population reacts to these procedures is quite different. In the hospital case, the patients only evacuated once a member of the nursing staff had instructed them to do so, while in the university evacuation, the students were less dependent upon the actions of the staff, with over 50% of them evacuating with no prior prompting. In addition, the student pre-evacuation time was found to be dependent on their level of engagement in various activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Participation in European Union research projects now requires the setting-up of a project website. This paper discusses the creation of the "Matrix" to facilitate the information visualisation of a project; experiments, data, and results, etc, i.e. information far beyond the promotional details of the website. The paper describes the theory of such an endeavour before proceeding to discuss the practical realities for this case study project. Finally, we consider any lessons that can be learnt from this real-world application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two evacuation trials were conducted within Brazilian library facilities by FSEG staff in January 2005. These trials represent one of the first such trials conducted in Brazil. The purpose of these evacuation trials was to collect pre-evacuation time data from a population with a cultural background different to that found in western Europe. In total some 34 pre-evacuation times were collected from the experiments and these ranged from 5 to 98 seconds with a mean pre-evacuation time of 46.7 seconds

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite being exposed to the harsh sea-spray environment of the North Sea at Arbroath, Scotland, for over 63 years, many of the reinforced concrete precast beam elements of the 1.5 km long promenade railing are still in very good condition and show little evidence of reinforcement corrosion. In contrast, railing replacements constructed in about 1968 and in 1993 are almost all badly cracked as a result of extensive corrosion of the longitudinal reinforcement. This is despite the newer concrete appearing to be of better quality than the 1943 concrete. Statistics for maximum crack width for each of the three populations, based on measurements made in 2004 and in 2006, are presented. In situ and laboratory measurements show that the 1943 concrete appears to have high permeability but it also shows high electrical resistivity. Chloride penetration measurements show the 1943 and 1993 concretes to have similar chloride profiles and similar chloride concentrations at the reinforcement bars. This is inconsistent with the 1943 beams showing much less reinforcement corrosion than their later replacements and casts doubt on the conventional practice for durability design focusing on reducing concrete permeability through denser concretes or greater cover.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article outlines the process of taking a manual blood pressure measurement. The author suggests that it is a skill that nursing students should be using in clinical practice rather than relying on automated monitors.