3 resultados para insertion torque

em Greenwich Academic Literature Archive - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been a recent revival of interest in the register insertion (RI) protocol because of its high throughput and low delay characteristics. Several variants of the protocol have been investigated with a view to integrating voice and data applications on a single local area network (LAN). In this paper the performance of an RI ring with a variable size buffer is studied by modelling and simulation. The chief advantage of the proposed scheme is that an efficient but simple bandwidth allocation scheme is easily incorporated. Approximate formulas are derived for queue lengths, queueing times, and total end-to-end transfer delays. The results are compared with previous analyses and with simulation estimates. The effectiveness of the proposed protocol in ensuring fairness of access under conditions of heavy and unequal loading is investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of the register insertion protocol for mixed voice-data traffic is investigated by simulation. The simulation model incorporates a common insertion buffer for station and ring packets. Bandwidth allocation is achieved by imposing a queue limit at each node. A simple priority scheme is introduced by allowing the queue limit to vary from node to node. This enables voice traffic to be given priority over data. The effect on performance of various operational and design parameters such as ratio of voice to data traffic, queue limit and voice packet size is investigated. Comparisons are made where possible with related work on other protocols proposed for voice-data integration. The main conclusions are: (a) there is a general degradation of performance as the ratio of voice traffic to data traffic increases, (b) substantial improvement in performance can be achieved by restricting the queue length at data nodes and (c) for a given ring utilisation, smaller voice packets result in lower delays for both voice and data traffic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of crank configuration on muscle activity and torque production during submaximal arm crank ergometry. Thirteen non-specifically trained male participants volunteered. During the research trials they completed a warm-up at 15 W before two 3-min exercise stages were completed at 50 and 100 W; subjects used either a synchronous or asynchronous pattern of cranking. During the final 30-s of each submaximal exercise stage electromyographic and torque production data were collected. After the data had been processed each parameter was analysed using separate 2-way ANOVA tests with repeated measures. The activity of all muscles increased in line with external workload, although a shift in the temporal pattern of muscle activity was noted between crank configurations. Patterns of torque production during asynchronous and synchronous cranking were distinct. Furthermore, peak, minimum and delta (peak-minimum) torque values were different (P < 0.05) between crank configurations at both workloads. For example, at 100 W, peak torque using synchronous [19.6 (4.3) Nm] cranking was higher (P < 0.05) compared to asynchronous [16.8 (1.6) Nm] cranking. In contrast minimum torque was lower (P < 0.05) at 100 W using synchronous [4.8 (1.7) Nm] compared to asynchronous [7.3 (1.2) Nm] cranking. There was a distinct bilateral asymmetry in torque production during asynchronous cranking with the dominant transmitting significantly more force to the crank arm. Taken together, these preliminary data demonstrate the complex nature of muscle activity during arm crank ergometry performed with an asynchronous or synchronous crank set-up. Further work is required to determine how muscle activity (EMG activity) and associated patterns of torque production influence physiological responses and functional capacity during arm crank ergometry.