7 resultados para differential scanning calorimetry (DSC) kinetics
em Greenwich Academic Literature Archive - UK
Resumo:
Purpose. To examine the thermal transition(s) between different polymorphic forms of Nifedipine and to define experimental conditions that lead to the generation of polymorph IV. Methods. Experiments were performed using a DSC 823e (Mettler Toledo). Nifedipine exists in four polymorphic forms, as well as an amorphous state. Examination of Nifedipine was conducted using the following method(s): cycle 1: 25ºC to 190ºC, 190ºC to 25ºC (formation of amorphous Nifedipine); cycle 2: 25ºC to X (60,70,80...150ºC), X to 25ºC; cycle 3: 25ºC to 190ºC and holding isothermally for 5 min between cycles (heating/cooling rate of 10ºC/min). Results. The amorphous state Nifedipine can sustain heating up to 90ºC without significant changes in its composition. Cycle 2 of amorphous material heated up to 90ºC shows only the glass transition at ~44ºC. In cycle 3 of the same material, a glass transition has been recorded at ~44ºC, followed by two exotherms (~100 and ~115ºC (crystallisation of polymorph III and II, respectively) and an endotherm (169ºC (melting of polymorphs I/II)). Samples that have been heated to temperatures between 100ºC and 120ºC in the second cycle showed a glass transition at ~44ºC and an additional exotherm at ~95ºC (crystallisation of polymorph III) on cooling a exotherm was observed at ~40ºC (crystallisation of polymorph IV). The same material showed no glass transition in cycle 3 but an endotherm at around 62ºC (melting of polymorph IV) an exotherm (~98ºC) and an endotherm (169ºC) melting of polymorph I/II. Heating the sample to a temperatures greater than 130ºC in cycle two results in a glass transition at ~44ºC, and two exotherms at ~102 and 125ºC (crystallisation of polymorphs III and I, respectively). Conclusions. DSC data suggests that polymorph IV can only be produced from amorphous or polymorph III samples. The presence of polymorph I or II drives the conversion of the less stable polymorphic form IV into the most stable form, I. Although form IV of Nifedipine can easily be created, following defined experimental conditions, it may only coexist with amorphous or polymorph III states. When polymorphs I and II are present in the sample polymorph IV cannot be etected.
Resumo:
Purpose. To study thermal stability of Aspirin and define thermal events that are associated with the thermal degradation of aspirin. Methods. Experiments were performed using a DSC 823e (Mettler Toledo, Swiss). Aspirin is prone to thermal degradation upon exposure to high temperatures. The melting point of aspirin is 140.1±0.4ºC (DSC). Aspirin has been examined by heating samples to 120ºC, 155ºC and 185ºC with subsequent cooling to -55ºC and a final heating to 155ºC. Although different heating and cooling ranges have been used, only results obtained at a rate of 10ºC/min will be presented. All runs where conducted in hermetically sealed pans. Results. Upon heating the sample to 120ºC no significant thermal event can be detected. After cooling the sample and reheating a glass transition can be observed at ~-8ºC, followed by the melting of aspirin at ~139ºC. By heating the sample to 155ºC melting of aspirin has been detected at ~139ºC. On cooling and subsequent heating a glass transition occurs at ~-32ºC, together with a broad crystallisation (onset at ~38ºC and peak maximum at ~57ºC) followed by a broad melting with an onset at 94ºC and peak maximum at ~112ºC. Finally, by heating the sample to 185ºC melting at ~ 139ºC was observed, and upon cooling and reheating a glass transition was detected at ~-26ºC and no further events could be recorded. Conclusions. This research demonstrates that the degradation steps of Aspirin depend on the thermal treatment. The main degradation products of different thermal treatments are currently unknown it is clear that acetic acid, which is one of the degradation products, acts as an antiplasticiser by lowering the glass transition temperature. In addition, due to the presence of the degradation products in liquid form (observed by hot stage microscopy), Aspirin is still present in the sample and recrystallises during the second heating step and melts at much lower temperatures.
Resumo:
Guest-host interactions of ibuprofen tromethamine salt (Ibu.T) with native and modified cyclodextrins (CyDs) have been investigated using several techniques, namely phase solubility diagrams (PSDs), proton nuclear magnetic resonance (H-1 NMR), differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FT-IR), X-ray powder diffractometry (XRPD). scanning-electron microscopy (SEM) and molecular mechanics (MM). From the analysis of PSD data (A(L)-type) it is concluded that the anionic tromethamine salt of ibuprofen (pK(a) = 4.55) forms 1: 1 soluble complexes with all CyDs investigated in buffered water at pH 7.0, while the neutral form of Ibu forms an insoluble complex with beta-CyD (B-S-type) in buffered water at pH 2.0. Ibu.T has a lower tendency to complex with beta-CyD (K-11 = 58 M-1 at pH 7.0) compared with the neutral Ibu (K-11 = 4200 M (1)) in water. Complex formation of Ibu.T with beta-CyD (Delta G degrees = -20.4 kJ/mol) is enthalpy driven (Delta H degrees = -22.9 kJ/mol) and is accompanied by a small unfavorable entropy (Delta S degrees = -8.4 J/mol K) change. H-1 NMR studies and MM computations revealed that, on complexation, the hydrophobic central benzene ring of lbu.T and part of the isobutyl group reside within the beta-CyD cavity leaving the peripheral groups (carboxylate, tromethamine and methyl groups) located near the hydroxyl group networks at either rim of beta-CyD. PSD, H-1 NMR, DSC, FT-IR, XRPD, SEM and MM studies confirmed the formation of Ibu.T/beta-CyD inclusion complex in solution and the solid state. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A review of polymer cure models used in microelectronics packaging applications reveals no clear consensus of the chemical rate constants for the cure reactions, or even of an effective model. The problem lies in the contrast between the actual cure process, which involves a sequence of distinct chemical reactions, and the models, which typically assume only one, (or two with some restrictions on the independence of their characteristic constants.) The standard techniques to determine the model parameters are based on differential scanning calorimetry (DSC), which cannot distinguish between the reactions, and hence yields results useful only under the same conditions, which completely misses the point of modeling. The obvious solution is for manufacturers to provide the modeling parameters, but failing that, an alternative experimental technique is required to determine individual reaction parameters, e.g. Fourier transform infra-red spectroscopy (FTIR).
Resumo:
A review of polymer cure models used in microelectronics packaging applications reveals no clear consensus of the chemical rate constants for the cure reactions, or even of an effective model. The problem lies in the contrast between the actual cure process, which involves a sequence of distinct chemical reactions, and the models, which typically assume only one, (or two with some restrictions on the independence of their characteristic constants.) The standard techniques to determine the model parameters are based on differential scanning calorimetry (DSC), which cannot distinguish between the reactions, and hence yields results useful only under the same conditions, which completely misses the point of modeling. The obvious solution is for manufacturers to provide the modeling parameters, but failing that, an alternative experimental technique is required to determine individual reaction parameters, e.g. Fourier transform infra-red spectroscopy (FTIR).
Resumo:
Silica nanoparticles (MSNs) with a highly ordered mesoporous structures (103A) with cubic Im3 m have been synthesized using triblock copolymers with high poly(alkylene oxide) (EO) segments in acid media. The produced nanoparticles displayed large specific surface area (approximately 765 cm(2)/g) with an average particles size of 120 nm. The loading efficiency was assessed by incorporating three major antiepileptic active substances via passive loading and it was found to varying from 17 to 25%. The state of the adsorbed active agents was further analyzed using differential scanning calorimetry (DSC) and X-ray powder diffraction (XRPD). Dissolution studies revealed rapid release profiles within the first 3 h. The viability of 3T3 endothelial cells was not affected in the presence of MSNs indicating negligible cytotoxicity. 2009 Elsevier B.V. All rights reserved.
Resumo:
A particle swarm optimisation approach is used to determine the accuracy and experimental relevance of six disparate cure kinetics models. The cure processes of two commercially available thermosetting polymer materials utilised in microelectronics manufacturing applications have been studied using a differential scanning calorimetry system. Numerical models have been fitted to the experimental data using a particle swarm optimisation algorithm which enables the ultimate accuracy of each of the models to be determined. The particle swarm optimisation approach to model fitting proves to be relatively rapid and effective in determining the optimal coefficient set for the cure kinetics models. Results indicate that the singlestep autocatalytic model is able to represent the curing process more accurately than more complex model, with ultimate accuracy likely to be limited by inaccuracies in the processing of the experimental data.