17 resultados para critical moisture
em Greenwich Academic Literature Archive - UK
Resumo:
As part of a comprehensive effort to predict the development of caking in granular materials, a mathematical model is introduced to model simultaneous heat and moisture transfer with phase change in porous media when undergoing temperature oscillations/cycling. The resulting model partial differential equations were solved using finite-volume procedures in the context of the PHYSICA framework and then applied to the analysis of sugar in storage. The influence of temperature on absorption/desorption and diffusion coefficients is coupled into the transport equations. The temperature profile, the depth of penetration of the temperature oscillation into the bulk solid, and the solids moisture content distribution were first calculated, and these proved to be in good agreement with experimental data. Then, the influence of temperature oscillation on absolute humidity, moisture concentration, and moisture migration for different parameters and boundary conditions was examined. As expected, the results show that moisture near boundary regions responds faster than farther away from them with surface temperature changes. The moisture absorption and desorption in materials occurs mainly near boundary regions (where interactions with the environment are more pronounced). Small amounts of solids moisture content, driven by both temperature and vapour concentration gradients, migrate between boundary and center with oscillating temperature.
Resumo:
Anisotropic conductive film (ACF) which consists of an adhesive epoxy matrix and randomly distributed conductive particles are widely used as the connection material for electronic devices with high I/O counts. However, for the semiconductor industry the reliability of the ACF is still a major concern due to a lack of experimental reliability data. This paper reports the investigations into the moisture-induced failures in Flip-Chip-on-Flex interconnections with Anisotropic Conductive Films (ACFs). Both experimental and modeling methods were applied. In the experiments, the contact resistance was used as a quality indicator and was measured continuously during the accelerated tests (autoclave tests). The temperature, relative humidity and the pressure were set at 121°C, 100%RH, and 2atm respectively. The contact resistance of the ACF joints increased during the tests and nearly 25% of the joints were found to be open after 168 hours’ testing time. Visible conduction gaps between the adhesive and substrate pads were observed. Cracks at the adhesive/flex interface were also found. For a better understanding of the experimental results, 3-D Finite Element (FE) models were built and a macro-micro modeling method was used to determine the moisture diffusion and moisture-induced stresses inside the ACF joints. Modeling results are consistent with the findings in the experimental work.
Resumo:
This paper reports the investigations into the moisture induced failures in flip-chip-on-flex interconnections with anisotropic conductive films (ACF). Both experimental and modeling methods were applied. In the experiments, the contact resistance was used as a quality indicator and was measured continuously during the accelerated tests (autoclave tests). The temperature, relative humidity and the pressure were set at 121°C, 100%RH, 1atm respectively. The contact resistance of the ACF joints increased during the tests and nearly 25% of the joints were found to be open after 168 hours' testing time. Visible conduction gaps between the adhesive and substrate pads were observed. Cracks at the adhesive/flex interface were also found. It is believed that the swelling effect of the adhesive and the water penetration along the adhesive/flex interface are the main causes of this contact degradation. Another finding from the experimental work was that the ACF interconnections that had undergone the reflow treatment were more sensitive to the moisture and showed worse reliability during the tests. For a better understanding of the experimental results, 3D finite element (FE) models were built and a macro-micro modeling method was used to determine the moisture diffusion and moisture-induced stresses inside the ACF joints. Modeling results are consistent with the findings in the experimental work.
Resumo:
Anisotropic conductive film (ACF) which consists of an adhesive epoxy matrix and randomly distributed conductive particles are widely used as the connection material for electronic devices with high I/O counts. However, for the semiconductor industry the reliability of the ACF is still a major concern due to a lack of experimental reliability data. This paper reports an investigation into the moisture effects on the reliability of ACF interconnections in the flip-chip-on-flex (FCOF) applications. A macro-micro 3D finite element modeling technique was used in order to make the multi-length-scale modeling of the ACF flip chip possible. The purposes of this modeling work was to understand the role that moisture plays in the failure of ACF flip chips, and to look into the influence of physical properties and geometric characteristics, such as the coefficient of the moisture expansion (CME), Young's modulus of the adhesive matrix and the bump height on the reliability of the ACF interconnections in a humid environment. Simulation results suggest that moisture-induced swelling of the adhesive matrix is the major cause of the ACF joint opening. Modeling results are consistent with the findings in the experimental work.
Resumo:
Purpose – This paper discusses the use of modelling techniques to predict the reliability of an anisotropic conductive film (ACF) flip chip in a humid environment. The purpose of this modelling work is to understand the role that moisture plays in the failure of ACF flip chips. Design/methodology/approach – A 3D macro-micro finite element modelling technique was used to determine the moisture diffusion and moisture-induced stresses inside the ACF flip chip. Findings – The results show that the ACF layer in the flip chip can be expected to be fully saturated with moisture after 3?h at 121°C, 100%RH, 2?atm test conditions. The swelling effect of the adhesive due to this moisture absorption causes predominately tensile stress at the interface between the adhesive and the metallization, which could cause a decrease in the contact area, and therefore an increase in the contact resistance. Originality/value – This paper introduces a macro-micro modelling technique which enables more detailed 3D modelling analysis of an ACF flip chip than previously.
Resumo:
In this paper, we shall critically examine a special class of graph matching algorithms that follow the approach of node-similarity measurement. A high-level algorithm framework, namely node-similarity graph matching framework (NSGM framework), is proposed, from which, many existing graph matching algorithms can be subsumed, including the eigen-decomposition method of Umeyama, the polynomial-transformation method of Almohamad, the hubs and authorities method of Kleinberg, and the kronecker product successive projection methods of Wyk, etc. In addition, improved algorithms can be developed from the NSGM framework with respects to the corresponding results in graph theory. As the observation, it is pointed out that, in general, any algorithm which can be subsumed from NSGM framework fails to work well for graphs with non-trivial auto-isomorphism structure.
Resumo:
A review of polymer cure models used in microelectronics packaging applications reveals no clear consensus of the chemical rate constants for the cure reactions, or even of an effective model. The problem lies in the contrast between the actual cure process, which involves a sequence of distinct chemical reactions, and the models, which typically assume only one, (or two with some restrictions on the independence of their characteristic constants.) The standard techniques to determine the model parameters are based on differential scanning calorimetry (DSC), which cannot distinguish between the reactions, and hence yields results useful only under the same conditions, which completely misses the point of modeling. The obvious solution is for manufacturers to provide the modeling parameters, but failing that, an alternative experimental technique is required to determine individual reaction parameters, e.g. Fourier transform infra-red spectroscopy (FTIR).
Resumo:
This, the second edition, adopts a critical and theoretical perspective on remuneration policy and practices in the UK, from the decline of collective bargaining to the rise of more individualistic systems based on employee performance. It tackles the conceptual issues missing from existing texts in the field of HRM by critically examining the latest academic literature on the topic. [Taken from publisher's product description].
Resumo:
The U&I programme Critical Friends (CFs) are developing guidelines on the role of the Critical Friend and the way in which this links with U&I programme model, projects and outputs. The critical friends are also in the process of building a new online community of shared effective practice for current and future critical friends. The CF Benefits Realisation project aims to synthesise existing CF U&I, JISC Curriculum Design and Delivery, JISC Institutional Innovation and related programmes, activities, methodologies and approaches to produce a range of specialist guidelines and other outputs for effective CF practice, within the context of the aims and objectives of the JISC U&I programme. We aim to disseminate these to a wide range of interests within the JISC HE-FE communities, following consultation.
Resumo:
The drug calculation skill of nurses continues to be a national concern. The continued concern has led to the introduction of mandatory drug calculation skills tests which students must pass in order to go on to the nursing register. However, there is little evidence to demonstrate that nurses are poor at solving drug calculation in practice. This paper argues that nurse educationalists have inadvertently created a problem that arguably does not exist in practice through use of invalid written drug assessment tests and have introduced their own pedagogical practice of solving written drug calculations. This paper will draw on literature across mathematics, philosophy, psychology and nurse education to demonstrate why written drug assessments are invalid, why learning must take place predominantly in the clinical area and why the key focus on numeracy and formal mathematical skills as essential knowledge for nurses is potentially unnecessary.
Resumo:
Environmental science is often described as an interdisciplinary subject, but one firmly grounded in positivist science. Less well recognized is the idea that interdisciplinarity actually challenges fundamental conceptions concerning how reality is understood from an orthodox science perspective. Drawing on recent non-dualism (or post-natural) literature, it is suggested in this paper that there is a need for greater awareness and debate concerning the underlying challenges that ideas of interdisciplinarity and holism present for environmental science. It is argued by aligning environmental science more strongly with non-dualistic traditions (spanning the sciences, arts and religion), fundamental issues are raised concerning how reality is understood and what constitutes valid research methodologies. The concept of intrinsic value is used as one example of the way non-dualistic theory can open up new territories for exploring reality.
Resumo:
An aqueous solution of sucrose was lyophilised, producing amorphous sucrose. This wasthen stored under different humidity at 25ºC for 1 week, allowing some samples tocrystallise. FT-Raman spectroscopy and PXRD have been successfully shown toqualitatively distinguish between amorphous and crystalline samples of sucrose. The datafrom the two techniques is complementary.
Resumo:
Many women who have higher–risk pregnancies, complications or medical conditions require specialist obstetric or multidisciplinary care. Increasingly women, whose condition deteriorates and becomes critical during childbirth, are being cared for by midwives in obstetric high dependency units within the labour ward, rather than being cared for by nurses in ITU. Critical Care in Childbearing for Midwives explores all aspects of management, support and care of childbearing women who become critically ill due to pre–existing conditions or who develop critical illness as a result of complications of childbearing. It examines predisposing factors which result in the need for critical care, addresses specialist monitoring technology and skills, and explores autonomous practice and team approaches to providing care for critically ill women in childbearing.