3 resultados para contrast analysis

em Greenwich Academic Literature Archive - UK


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Network analysis is distinguished from traditional social science by the dyadic nature of the standard data set. Whereas in traditional social science we study monadic attributes of individuals, in network analysis we study dyadic attributes of pairs of individuals. These dyadic attributes (e.g. social relations) may be represented in matrix form by a square 1-mode matrix. In contrast, the data in traditional social science are represented as 2-mode matrices. However, network analysis is not completely divorced from traditional social science, and often has occasion to collect and analyze 2-mode matrices. Furthermore, some of the methods developed in network analysis have uses in analysing non-network data. This paper presents and discusses ways of applying and interpreting traditional network analytic techniques to 2-mode data, as well as developing new techniques. Three areas are covered in detail: displaying 2-mode data as networks, detecting clusters and measuring centrality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite being exposed to the harsh sea-spray environment of the North Sea at Arbroath, Scotland, for over 63 years, many of the reinforced concrete precast beam elements of the 1.5 km long promenade railing are still in very good condition and show little evidence of reinforcement corrosion. In contrast, railing replacements constructed in about 1968 and in 1993 are almost all badly cracked as a result of extensive corrosion of the longitudinal reinforcement. This is despite the newer concrete appearing to be of better quality than the 1943 concrete. Statistics for maximum crack width for each of the three populations, based on measurements made in 2004 and in 2006, are presented. In situ and laboratory measurements show that the 1943 concrete appears to have high permeability but it also shows high electrical resistivity. Chloride penetration measurements show the 1943 and 1993 concretes to have similar chloride profiles and similar chloride concentrations at the reinforcement bars. This is inconsistent with the 1943 beams showing much less reinforcement corrosion than their later replacements and casts doubt on the conventional practice for durability design focusing on reducing concrete permeability through denser concretes or greater cover.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A review of polymer cure models used in microelectronics packaging applications reveals no clear consensus of the chemical rate constants for the cure reactions, or even of an effective model. The problem lies in the contrast between the actual cure process, which involves a sequence of distinct chemical reactions, and the models, which typically assume only one, (or two with some restrictions on the independence of their characteristic constants.) The standard techniques to determine the model parameters are based on differential scanning calorimetry (DSC), which cannot distinguish between the reactions, and hence yields results useful only under the same conditions, which completely misses the point of modeling. The obvious solution is for manufacturers to provide the modeling parameters, but failing that, an alternative experimental technique is required to determine individual reaction parameters, e.g. Fourier transform infra-red spectroscopy (FTIR).