3 resultados para alpha and vector model
em Greenwich Academic Literature Archive - UK
Resumo:
Abstract not available
Resumo:
In this article, the buildingEXODUS (V1.1) evacuation model is described and discussed and attempts at qualitative and quantitative model validation are presented. The data set used for the validation is the Tsukuba pavilion evacuation data. This data set is of particular interest as the evacuation was influenced by external conditions, namely inclement weather. As part of the validation exercise, the sensitivity of the buildingEXODUS predictions to a range of variables and conditions is examined, including: exit flow capacity, occupant response times, and the impact of external conditions on the developing evacuation. The buildingEXODUS evacuation model was found to produce good qualitative and quantitative agreement with the experimental data.
Resumo:
The FIREDASS (FIRE Detection And Suppression Simulation) project is concerned with the development of fine water mist systems as a possible replacement for the halon fire suppression system currently used in aircraft cargo holds. The project is funded by the European Commission, under the BRITE EURAM programme. The FIREDASS consortium is made up of a combination of Industrial, Academic, Research and Regulatory partners. As part of this programme of work, a computational model has been developed to help engineers optimise the design of the water mist suppression system. This computational model is based on Computational Fluid Dynamics (CFD) and is composed of the following components: fire model; mist model; two-phase radiation model; suppression model and detector/activation model. The fire model - developed by the University of Greenwich - uses prescribed release rates for heat and gaseous combustion products to represent the fire load. Typical release rates have been determined through experimentation conducted by SINTEF. The mist model - developed by the University of Greenwich - is a Lagrangian particle tracking procedure that is fully coupled to both the gas phase and the radiation field. The radiation model - developed by the National Technical University of Athens - is described using a six-flux radiation model. The suppression model - developed by SINTEF and the University of Greenwich - is based on an extinguishment crietrion that relies on oxygen concentration and temperature. The detector/ activation model - developed by Cerberus - allows the configuration of many different detector and mist configurations to be tested within the computational model. These sub-models have been integrated by the University of Greenwich into the FIREDASS software package. The model has been validated using data from the SINTEF/GEC test campaigns and it has been found that the computational model gives good agreement with these experimental results. The best agreement is obtained at the ceiling which is where the detectors and misting nozzles would be located in a real system. In this paper the model is briefly described and some results from the validation of the fire and mist model are presented.