4 resultados para WIDE-RANGE CURRENT MEASUREMENT

em Greenwich Academic Literature Archive - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The U&I programme Critical Friends (CFs) are developing guidelines on the role of the Critical Friend and the way in which this links with U&I programme model, projects and outputs. The critical friends are also in the process of building a new online community of shared effective practice for current and future critical friends. The CF Benefits Realisation project aims to synthesise existing CF U&I, JISC Curriculum Design and Delivery, JISC Institutional Innovation and related programmes, activities, methodologies and approaches to produce a range of specialist guidelines and other outputs for effective CF practice, within the context of the aims and objectives of the JISC U&I programme. We aim to disseminate these to a wide range of interests within the JISC HE-FE communities, following consultation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Considerable variation in the prevalence of childhood asthma and its symptoms (wheezing) has been observed in previous studies and there is evidence that the prevalence has been increasing over time. Methods: We have systematically reviewed the reported prevalence and time trends of wheezing symptoms among children, worldwide and within the same country over time. All studies comprising more than 1000 persons and meeting certain other quality criteria published over a 16-year period, between January 1990 and December 2005, are reported and a comparison of ISAAC (International Study of Asthma and Allergies in Childhood) and non-ISAAC studies is made, in part as a way of expanding the power to examine time trends (the older studies tend to be non-ISAAC), but also to examine possible methodological differences between ISAAC and non-ISAAC questions. Results: A wide range of current prevalence of wheeze was observed between and within countries over time. The UK had the highest recorded prevalence of 32.2% in children aged 13–14 in 1994–5 and Ethiopia had the lowest prevalence, 1.7% in children aged 10–19 in 1996. All studies in Australia and the UK were compared using multiple logistic regression. ISAAC phase I and III studies reported significantly higher prevalence of current wheeze (OR = 1.638) compared with non-ISAAC studies, after adjusting for various other factors (country, survey year, age of child, parental vs child response to the survey). Australia showed a significantly higher prevalence of current wheezing (OR = 1.343) compared with the UK, there was a significant increase in the prevalence odds ratio per survey year (2.5% per year), a significant decrease per age of child (0.7% per year), and a significantly higher response in current wheezing if the response was self-completed by the child (OR = 1.290). These factors, when explored separately for ISAAC and non-ISAAC studies, showed very different results. In ISAAC studies, or non-ISAAC studies using ISAAC questions, there was a significant decrease in current wheezing prevalence over time (2.5% per year). In non-ISAAC studies, which tend to cover an earlier period, there was a significant increase (2.6% per year) in current wheezing prevalence over time. This is very likely to be a result of prevalence of wheezing increasing from the 1970s up to the early 1990s, but decreasing since then. Conclusion: The UK has the highest recorded prevalence of wheezing and Ethiopia the lowest. Prevalence of wheezing in Australia and the UK has increased from the 1970s up to the early 1990s, but decreased since then and ISAAC studies report significantly higher prevalences than non-ISAAC studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper concerns the use of a non-destructive ultrasonic technique for characterising the rheological properties of solder paste and specifically, the use of through-mode microsecond ultrasonic pulses for evaluation of viscoelastic properties of paste materials at the molecular level. Ultrasonic techniques are a widely used and a reliable form of non-destructive testing of materials. This is because techniques such as ultrasounds while used for testing or monitoring material properties, has offered immense benefits in applications where access to the sample is restricted or when handling the sample for testing could interfere with the monitoring or analysis process. Very often, this would mean that the measurements taken are not a true representation of the behaviour of the material (due to externally incorporated changes into the material's physical state during the removal or testing process). Ultrasonic based techniques are being increasingly used for quality control and production monitoring functions which requires evaluation of the changes in material properties over wide range of industrial applications such as cement paste quality, plastic/polymer extrusion process, dough, and even sugar content in beverage drinks. In addition, ultrasound techniques are of great interest for their capacity to take rapid measurements in systems which are optically opaque. The viscometer and rheometer are two of the most widely used rheological instruments used in industry for monitoring the quality of solder pastes, during the production and packaging stage. One of the potential limitations of viscometer and rheometer based measurements is that the collection and preparation of the solder paste samples can irreversibly alter the structure and flow behaviour of the sample. Hence the measurement may not represent the actual quality of the whole production batch. Secondly, rheological measurements and the interpretation of rheological data is a very technical and time consuming process, which requires professionally trained R&D personnel. It is for these reasons that materials suppliers (who formulate and produce solder pastes) and solder paste consumers (especially, contract electronics manufacturers) are keen to see the development of simple, easy to use and accurate techniques for the theological characterisation of solder pastes. The results from the work show that the technique can be used by R&D personnel involved in paste formulation and manufacture to monitor the batch-to-batch quality and consistency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the application of a non-destructive ultrasonic technique for characterising the rheological properties of solder paste through the use of through-mode microsecond ultrasonic pulses for evaluation of viscoelastic properties of lead-free solder paste containing different types of flux. Ultrasonic techniques offer a robust and reliable form of non-destructive testing of materials where access to the sample is restricted or when sample handling can interfere with the monitoring or analysis process due to externally incorporated changes to the material’s physical state or accidental contamination during the removal or testing process. Ultrasonic based techniques are increasingly used for quality control and production monitoring functions which requires evaluation of changes in material properties for a wide range of industrial applications such as cement paste quality, plastic/polymer extrusion process, dough and even sugar content in beverage drinks. In addition, ultrasound techniques are of great interest for their capability to take rapid measurements in systems which are optically opaque. The conventional industry approach for characterising the rheological properties of suspensions during processing/packaging stage is mainly through the use of viscometer and some through the use of rheometer. One of the potential limitations of viscometer and rheometer based measurements is that the collection and preparation of the solder paste samples can irreversibly alter the structure and flow behaviour of the sample. Hence the measurement may not represent the actual quality of the whole production batch. Secondly, rheological measurements and the interpretation of rheological data is a very technical and time consuming process, which requires professionally trained R&D personnel. The ultrasound technique being proposed provides simple, yet accurate and easy to use solution for the in-situ rheological characterisation of solder pastes which will benefit the materials suppliers (who formulate and produce solder pastes) and solder paste consumers (especially, contract electronics manufacturers). The results from the work show that the technique can be used by R&D personnel involved in paste formulation and manufacture to monitor the batch-to-batch quality and consistency.