4 resultados para Rectangular patch

em Greenwich Academic Literature Archive - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a comparison of fire field model predictions with experiment for the case of a fire within a compartment which is vented (buoyancydriven) to the outside by a single horizontal ceiling vent. Unlike previous work, the mathematical model does not employ a mixing ratio to represent vent temperatures but allows the model to predict vent temperatures a priori. The experiment suggests that the flow through the vent produces oscillatory behaviour in vent temperatures with puffs of smoke emerging from the fire compartment. This type of flow is also predicted by the fire field model. While the numerical predictions are in good qualitative agreement with observations, they overpredict the amplitudes of the temperature oscillations within the vent and also the compartment temperatures. The discrepancies are thought to be due to three-dimensional effects not accounted for in this model as well as using standard ‘practices’ normally used by the community with regards to discretization and turbulence models. Furthermore, it is important to note that the use of the k–ε turbulence model in a transient mode, as is used here, may have a significant effect on the results. The numerical results also suggest that a linear relationship exists between the frequency of vent temperature oscillation (n) and the heat release rate (Q0) of the type n∝Q0.290, similar to that observed for compartments with two horizontal vents. This relationship is predicted to occur only for heat release rates below a critical value. Furthermore, the vent discharge coefficient is found to vary in an oscillatory fashion with a mean value of 0.58. Below the critical heat release rate the mean discharge coefficient is found to be insensitive to fire size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An MHD flow is considered which is relevant to horizontal Bridgman technique for crystal growth from a melt. In the unidirectional parallel flow approximation an analytical solution is found accounting for the finite rectangular cross section of the channel in the case of a vertical magnetic field. Numerical pseudo-spectral solutions are used in the cases of arbitrary magnetic field and gravity vector orientations. The vertical magnetic field (parallel to the gravity) is found to be he most effective to damp the flow, however, complicated flow profiles with "overvelocities" in the comers are typical in the case of a finite cross-section channel. The temperature distribution is shown to be dependent on the flow profile. The linear stability of the flow is investigated by use of the Chebyshev pseudospectral method. For the case of an infinite width channel the transversal rolls instability is investigated, and for the finite cross-section channel the longitudinal rolls instability is considered. The critical Gr number values are computed in the dependence of the Ha number and the wave number or the aspect ratio in the case of finite section.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical simulation of heat transfer in a high aspect ratio rectangular microchannel with heat sinks has been conducted, similar to an experimental study. Three channel heights measuring 0.3 mm, 0.6mmand 1mmare considered and the Reynolds number varies from 300 to 2360, based on the hydraulic diameter. Simulation starts with the validation study on the Nusselt number and the Poiseuille number variations along the channel streamwise direction. It is found that the predicted Nusselt number has shown very good agreement with the theoretical estimation, but some discrepancies are noted in the Poiseuille number comparison. This observation however is in consistent with conclusions made by other researchers for the same flow problem. Simulation continues on the evaluation of heat transfer characteristics, namely the friction factor and the thermal resistance. It is found that noticeable scaling effect happens at small channel height of 0.3 mm and the predicted friction factor agrees fairly well with an experimental based correlation. Present simulation further reveals that the thermal resistance is low at small channel height, indicating that the heat transfer performance can be enhanced with the decrease of the channel height.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considers the circumstances in which repair works may be more appropriate than replacement where a landlord is attempting to claim under a repair covenant. Examines case law on which method is more appropriate and on the standard of remedial work to be undertaken. Reflects on the situation where performance of remedial works would be futile. Comments on the Technology and Construction Court ruling in Carmel Southend Ltd v Strachan & Henshaw Ltd on whether a landlord had been correct to carry out overcladding works to a roof where surveyors had agreed that patch repairs would be adequate.