9 resultados para Load rejection test data

em Greenwich Academic Literature Archive - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigates the use of computer modelled versus directly experimentally determined fire hazard data for assessing survivability within buildings using evacuation models incorporating Fractionally Effective Dose (FED) models. The objective is to establish a link between effluent toxicity, measured using a variety of small and large scale tests, and building evacuation. For the scenarios under consideration, fire simulation is typically used to determine the time non-survivable conditions develop within the enclosure, for example, when smoke or toxic effluent falls below a critical height which is deemed detrimental to evacuation or when the radiative fluxes reach a critical value leading to the onset of flashover. The evacuation calculation would the be used to determine whether people within the structure could evacuate before these critical conditions develop.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents both modelling and experimental test data to characterise the performance of four non-destructive tests. The focus is on determining the presence and rough magnitude of thermal fatigue cracks within the solder joints for a surface mount resistor on a strip of FR4 PCB. The tests all operate by applying mechanical loads to the PCB and monitoring the strain response at the top of the resistor. The modelling results show that of the four tests investigated, three are sensitive to the presence of a crack in the joint and its magnitude. Hence these tests show promise in being able to detect cracking caused by accelerated testing. The experimental data supports these results although more validation is required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To study the impact of powder flow properties on dosator filling systems, with particular focus on improvements in dose weight accuracy and repeatability. Method: This study evaluates a range of critical powder flow properties such as: flow function, cohesion, wall friction, adhesion to wall surfaces, density/compressibility data, stress ratio “K” and gas permeability. The characterisations of the powders considered in this study were undertaken using an annular shear cell using a sample size of 0.5 litres. This tester also incorporated the facility to measure bed expansion during shear in addition to contraction under consolidation forces. A modified Jenike type linear wall friction tester was used to develop the failure loci for the powder sample in conjunction with multiple wall samples (representing a variety of material types and surface finishes). Measurements of the ratio of applied normal stress versus lateral stress were determined using a piece of test equipment specifically designed for the purpose. Results: The correct characterisation of powders and the incorporation of this data into the design of process equipment are recognised as critical for reliable and accurate operation. An example of one aspect of this work is the stress ratio “K”. This characteristic is not well understood or correctly interpreted in many cases – despite its importance. Fig 1 [Omitted] (illustrates a sample of test data. The slope of the line gives the stress ratio in a uniaxial compaction system – indicating the behaviour of the material under compaction during dosing processes. Conclusions: A correct assessment of the bulk powder properties for a given formulation can allow prediction of: cavity filling behaviour (and hence dosage), efficiency of release from dosator, and strength and stability of extruded dose en route to capsule filling Influences over the effectiveness of dosator systems have been shown to be impacted upon by: bed pre-compaction history, gas permeability in the bed (with respect to local density effects), and friction effects for materials of construction for dosators

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a practical approach for the investigation, assessment and design of existing soakaways. This method can be utilised for measuring the performance and capacity of the systems and examining whether the systems are suitable for reuse when information about the design and installation of the systems is not available. The requirements for field observations and the procedure for a soil infiltration test for the installed system are suggested for successful assessment. The soil infiltration rate of the system is estimated from the field test data without requiring information on the design and construction details of the system. The system's working condition is measured by a performance indicator related to the time taken to empty the soakaway. This is then employed to evaluate the potential reuse of the system. The system's drain capacity is determined by the design principles of current practice and the effect of climate change on its drain capacity is considered. Contamination of soils around the systems after long-term use of discharge service and the water present in soakaway chambers are also investigated. A detailed case study for the reuse of four installed soakaways for a new housing development demonstrates how the proposed approach provides a straightforward process for the infiltration performance and drain capacity assessment of the existing systems. The effectiveness and applicability of the proposed approach are further demonstrated from the assessments for a number of installed systems over various sites

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Numerical predictions produced by the SMARTFIRE fire field model are compared with experimental data. The predictions consist of gas temperatures at several locations within the compartment over a 60 min period. The test fire, produced by a burning wood crib attained a maximum heat release rate of approximately 11MW. The fire is intended to represent a nonspreading fire (i.e. single fuel source) in a moderately sized ventilated room. The experimental data formed part of the CIB Round Robin test series. Two simulations are produced, one involving a relatively coarse mesh and the other with a finer mesh. While the SMARTFIRE simulations made use of a simple volumetric heat release rate model, both simulations were found capable of reproducing the overall qualitative results. Both simulations tended to overpredict the measured temperatures. However, the finer mesh simulation was better able to reproduce the qualitative features of the experimental data. The maximum recorded experimental temperature (12141C after 39 min) was over-predicted in the fine mesh simulation by 12%. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this Chapter we discuss the load-balancing issues arising in parallel mesh based computational mechanics codes for which the processor loading changes during the run. We briefly touch on geometric repartitioning ideas and then focus on different ways of using a graph both to solve the load-balancing problem and the optimisation problem, both locally and globally. We also briefly discuss whether repartitioning is always valid. Sample illustrative results are presented and we conclude that repartitioning is an attractive option if the load changes are not too dramatic and that there is a certain trade-off between partition quality and volume of data that the underlying application needs to migrate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a generic framework that can be used to describe study plans using meta-data. The context of this research and associated technologies and standards is presented. The approach adopted here has been developed within the mENU project that aims to provide a model for a European Networked University. The methodology for the design of the generic Framework is discussed and the main design requirements are presented. The approach adopted was based on a set of templates containing meta-data required for the description of programs of study and consisting of generic building elements annotated appropriately. The process followed to develop the templates is presented together with a set of evaluation criteria to test the suitability of the approach. The templates structure is presented and example templates are shown. A first evaluation of the approach has shown that the proposed framework can provide a flexible and competent means for the generic description of study plans for the purposes of a networked university.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates an isothermal fatigue test for solder joints developed at the NPL. The test specimen is a lap joint between two copper arms. During the test the displacement at the ends of the copper are controlled and the force measured. The modeling results in the paper show that the displacement across the solder joint is not equal to the displacement applied at the end of the specimen. This is due to deformation within the copper arms. A method is described to compensate for this difference. The strain distribution in the solder was determined by finite element analysis and compared to the distribution generated by a theoretical 'ideal' test which generates an almost pure shear mode in the solder. By using a damage-based constitutive law the shape of the crack generated in the specimen has been predicted for both the actual test and the ideal pure shear test. Results from the simulations are also compared with experimental data using SnAgCu solder.