6 resultados para Expert Microscopy
em Greenwich Academic Literature Archive - UK
Resumo:
We have investigated the early stages in the adsorption process of C60 molecules on a highly oriented pyrolitic graphite (HOPG) substrate. C60 powder was thermally evaporated in UHV of 10−8 Pa conditions onto a freshly cleaved HOPG surface. We did not observe individual fullerenes on the substrate for the case of short deposition times and low evaporation rates. However, small islands of C60 molecules with an fcc structure could be observed when the deposition rate was about 0.2 nm/min and the total thickness was above 1 nm. The islands did not grow in the vicinity of the HOPG steps. The typical lateral dimensions of these islands were of the order of a few hundred square nanometers, having thickness of up to five monolayers. We modified the shapes and positions of these islands by the STM tip, using a small (less than 1 V) bias voltage.
Resumo:
Probe-based scanning microscopes, such as the STM and the AFM, are used to obtain the topographical and electronic structure maps of material surfaces, and to modify their morphologies on nanoscopic scales. They have generated new areas of research in condensed matter physics and materials science. We will review some examples from the fields of experimental nano-mechanics, nano-electronics and nano-magnetism. These now form the basis of the emerging field of Nano-technology. A parallel development has been brought about in the field of Computational Nano-science, using quantum-mechanical techniques and computer-based numerical modelling, such as the Molecular Dynamics (MD) simulation method. We will report on the simulation of nucleation and growth of nano-phase films on supporting substrates. Furthermore, a theoretical modelling of the formation of STM images of metallic clusters on metallic substrates will also be discussed within the non-equilibrium Keldysh Green function method to study the effects of coherent tunnelling through different atomic orbitals in a tip-sample geometry.
Resumo:
SMARTFIRE, an open architecture integrated CFD code and knowledge based system attempts to make fire field modeling accessible to non-experts in Computational Fluid Dynamics (CFD) such as fire fighters, architects and fire safety engineers. This is achieved by embedding expert knowledge into CFD software. This enables the 'black-art' associated with the CFD analysis such as selection of solvers, relaxation parameters, convergence criteria, time steps, grid and boundary condition specification to be guided by expert advice from the software. The user is however given the option of overriding these decisions, thus retaining ultimate control. SMARTFIRE also makes use of recent developments in CFD technology such as unstructured meshes and group solvers in order to make the CFD analysis more efficient. This paper describes the incorporation within SMARTFIRE of the expert fire modeling knowledge required for automatic problem setup and mesh generation as well as the concept and use of group solvers for automatic and manual dynamic control of the CFD code.
Resumo:
Despite the apparent simplicity of the OpenMP directive shared memory programming model and the sophisticated dependence analysis and code generation capabilities of the ParaWise/CAPO tools, experience shows that a level of expertise is required to produce efficient parallel code. In a real world application the investigation of a single loop in a generated parallel code can soon become an in-depth inspection of numerous dependencies in many routines. The additional understanding of dependencies is also needed to effectively interpret the information provided and supply the required feedback. The ParaWise Expert Assistant has been developed to automate this investigation and present questions to the user about, and in the context of, their application code. In this paper, we demonstrate that knowledge of dependence information and OpenMP are no longer essential to produce efficient parallel code with the Expert Assistant. It is hoped that this will enable a far wider audience to use the tools and subsequently, exploit the benefits of large parallel systems.
Resumo:
Macromolecular therapeutics and nano-sized drug delivery systems often require localisation to specific intracellular compartments. In particular, efficient endosomal escape, retrograde trafficking, or late endocytic/lysosomal activation are often prerequisites for pharmacological activity. The aim of this study was to define a fluorescence microscopy technique able to confirm the localisation of water-soluble polymeric carriers to late endocytic intracellular compartments. Three polymeric carriers of different molecular weight and character were studied: dextrin (Mw~50,000 g/mol), a N-(2-hydroxypropyl)methacrylamide (HPMA) copolymer (Mw approximately 35,000 g/mol) and polyethylene glycol (PEG) (Mw 5000 g/mol). They were labelled with Oregon Green (OG) (0.3-3 wt.%; <3% free OG in respect of total). A panel of relevant target cells were used: THP-1, ARPE-19, and MCF-7 cells, and primary bovine chondrocytes (currently being used to evaluate novel polymer therapeutics) as well as NRK and Vero cells as reference controls. Specific intracellular compartments were marked using either endocytosed physiological standards, Marine Blue (MB) or Texas-red (TxR)-Wheat germ agglutinin (WGA), TxR-Bovine Serum Albumin (BSA), TxR-dextran, ricin holotoxin, C6-7-nitro-2,1,3-benzoxadiazol-4-yl (NBD)-labelled ceramide and TxR-shiga toxin B chain, or post-fixation immuno-staining for early endosomal antigen 1 (EEA1), lysosomal-associated membrane proteins (LAMP-1, Lgp-120 or CD63) or the Golgi marker GM130. Co-localisation with polymer-OG conjugates confirmed transfer to discreet, late endocytic (including lysosomal) compartments in all cells types. The technique described here is a particularly powerful tool as it circumvents fixation artefacts ensuring the retention of water-soluble polymers within the vesicles they occupy.
Resumo:
Introduction: The critical phase, in jumping events in track and field, appears to be between touchdown and take-off. Since obvious similarities exist between the take off phase in both long jump and pole vault, numerous 3D kinematics and electromyographic studies have only looked at long jump. Currently there are few detailed kinematics electromyographic data on the pole vault take-off phase. The aim of this study was therefore to characterise kinematics and electromyographic variables during the take-off phase to provide a better understanding of this phase in pole vaulting and its role in performance outcome. Material and methods: Six pole-vaulters took part in the study. Kinematics data were captured with retro reflective markers fixed on the body. Hip, knee and ankle angle were calculated. Differential bipolar surface electrodes were placed on the following muscles of the take-off leg: tibialis anterior, lateral gastrocnemius, vastus lateralis, rectus femoris, bicep femoris and gluteus maximus. EMG activity was synchronously acquired with the kinematic data. EMG data were rectified and smoothed using a second order low pass Butterworth Bidirectional filter (resulting in a 4th order filter) with a cut-off frequency of 14 Hz. Results: Evolution of hip, knee and ankle angle show no significant differences during the last step before touchdown, the take-off phase and the beginning of fly phase. Meanwhile, strong differences in EMG signal are noted inter and intra pole vaulter. However for a same subject the EMG activities seem to converge to some phase locked point. Discussion: All pole vaulters have approximately the same visible coordination This coordination reflects a different muscular control among pole vaulters but also for a considered pole vaulter. These phase locked point could be considered as invariant of motor control i.e. a prerequisite for a normal sequence of the movement and performance realization.