2 resultados para Exercise - Physiological aspects - Measurement

em Greenwich Academic Literature Archive - UK


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Theoretical and experimental studies of cross correlation techniques applied to non-restrictive velocity measurement of pneumatically conveyed solids using ring-shaped electrodynamic flow sensors are presented. In-depth studies of the electrodynamic sensing mechanism, and also of the spatial sensitivity and spatial filtering properties of the sensor are included, together with their relationships to measurement accuracy and the effects of solids' velocity profiles. The experimental evaluation of a 53 mm bore sensing head is described, including trials using a calibrated pneumatic conveyor circulating pulverized fuel and cement. Comparisons of test results with the mathematical models of the sensor are used to identify important aspects of the instrument design. Off-line test results obtained using gravity-fed solids flow show that the system repeatability is within +/-0.5% over the velocity range of 2-4 m s(-1) for volumetric concentrations of solids no greater than 0.2%. Results obtained in the pilot-plant trials demonstrate that the system is capable of achieving repeatability better than +/-2% and linearity within +/-2% over the velocity range 20-40 m s(-1) for volumetric concentrations of solids in the range 0.01-0.44%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine the effects of cadence and power output on physiological and biomechanical responses to incremental arm-crank ergometry (ACE). Ten male subjects (mean +/- SD age, 30.4 +/-5.4 y; height, 1.78 +/-0.07 m; mass, 86.1 +/-14.2 kg) undertook 3 incremental ACE protocols to determine peak oxygen uptake (VO2 peak; mean of 3 tests: 3.07 +/- 0.17 L.min-1) at randomly assigned cadences of 50, 70, or 90 r.min-1. Heart rate and expired air were continually monitored. Central (RPE-C) and local (RPE-L) ratings of perceived exertion were recorded at volitional exhaustion. Joint angles and trunk rotation were analysed during each exercise stage. During submaximal power outputs of 50, 70, and 90 W, oxygen consumption (VO2) was lowest for 50 r.min-1 and highest for 90 r.min-1 (p < 0.01). VO2 peak was lowest during 50 r.min-1 (2.79 +/-0.45 L.min-1; p < 0.05) when compared with both 70 r.min-1 and 90 r.min-1 (3.16 +/-0.58, 3.24 +/-0.49 L.min-1, respectively; p > 0.05). The difference between RPE-L and RPE-C at volitional exhaustion was greatest during 50 r.min-1 (2.9 +/- 1.6) when compared with 90 r.min-1 (0.9 +/- 1.9, p < 0.05). At VO2 peak, shoulder range of motion (ROM) and trunk rotation were greater for 50 and 70 r.min-1 when compared with 90 r.min-1 (p < 0.05). During submaximal power outputs, shoulder angle and trunk rotation were greatest at 50 r.min-1 when compared with 90 r.min-1 (p < 0.05). VO2 was inversely related to both trunk rotation and shoulder ROM during submaximal power outputs. The results of this study suggest that the greater forces required at lower cadences to produce a given power output resulted in greater joint angles and range of shoulder and trunk movement. Greater isometric contractions for torso stabilization and increased cost of breathing possibly from respiratory-locomotor coupling may have contributed increased oxygen consumption at higher cadences.