16 resultados para CR863.009 A663s
em Greenwich Academic Literature Archive - UK
Resumo:
We have implemented a large-scale classical molecular dynamics simulation at constant temperature to provide a theoretical insight into the results of a recently performed experiment on the monolayer and multi-layer formations of molecular films on the Si(100) reconstructed dimerized surface. Our simulation has successfully reproduced all of the morphologies observed on the monolayer film by this experiment. We have obtained the formation of both c(4 4) and c(4 3) structures of the molecules and have also obtained phase transitions of the former into the latter.
Resumo:
Background: This epidemiological study was carried out to establish the magnitude of the changing incidence of gastric and oesophageal cancer. Methods: Time-trend analyses of subsite-specific cancers of the oesophagus and stomach were performed using data from the Thames Cancer Registry database (1960-1996) for the South Thames Region. The changes in sex ratio and peak age of incidence are reported. Results: In the upper two-thirds of the oesophagus there was no significant change in the incidence rate, but the lower third of the oesophagus showed a marked rise for both sexes (average annual change + 0.05 for men, + 0.009 for women). For the gastric cardia, the incidence in males increased (average annual change + 0.025), while in females it remained unchanged. Cancers of the oesophagogastric junction showed a clear increase for both sexes (average annual change + 0.07 for men, + 0.009 for women). There were changes in the sex ratio and peak age of incidence for all subsite cancers for both sexes. Conclusion: Over a 37-year period the incidence of cancer of the oesophagogastric junction increased threefold, while the incidence of cancers of the other subsites of the stomach decreased. Further studies are needed to investigate the aetiology of these changes.
Resumo:
Fractal image compression is a relatively recent image compression method, which is simple to use and often leads to a high compression ratio. These advantages make it suitable for the situation of a single encoding and many decoding, as required in video on demand, archive compression, etc. There are two fundamental fractal compression methods, namely, the cube-based and the frame-based methods, being commonly studied. However, there are advantages and disadvantages in both methods. This paper gives an extension of the fundamental compression methods based on the concept of adaptive partition. Experimental results show that the algorithms based on adaptive partition may obtain a much higher compression ratio compared to algorithms based on fixed partition while maintaining the quality of decompressed images.
Resumo:
Melting of metallic samples in a cold crucible causes inclusions to concentrate on the surface owing to the action of the electromagnetic force in the skin layer. This process is dynamic, involving the melting stage, then quasi-stationary particle separation, and finally the solidification in the cold crucible. The proposed modeling technique is based on the pseudospectral solution method for coupled turbulent fluid flow, thermal and electromagnetic fields within the time varying fluid volume contained by the free surface, and partially the solid crucible wall. The model uses two methods for particle tracking: (1) a direct Lagrangian particle path computation and (2) a drifting concentration model. Lagrangian tracking is implemented for arbitrary unsteady flow. A specific numerical time integration scheme is implemented using implicit advancement that permits relatively large time-steps in the Lagrangian model. The drifting concentration model is based on a local equilibrium drift velocity assumption. Both methods are compared and demonstrated to give qualitatively similar results for stationary flow situations. The particular results presented are obtained for iron alloys. Small size particles of the order of 1 μm are shown to be less prone to separation by electromagnetic field action. In contrast, larger particles, 10 to 100 μm, are easily “trapped” by the electromagnetic field and stay on the sample surface at predetermined locations depending on their size and properties. The model allows optimization for melting power, geometry, and solidification rate.
Resumo:
An intriguing question, which until recently had not been directly explored by the courts, is the extent to which English law recognises body parts and products of the human body as property capable of ownership. Although the common law currently recognises no general property in a dead body (and only limited possessory rights in respect of it), this apparent “no-property rule” provides no justification, it is submitted, for denying proprietary status to parts or products of a living human body. The recent decision of the Court of Appeal in Yearworth v. North Bristol NHS Trust ([2009] EWCA Civ 37) lends strong support to the view that genetic material (as the product of a living human body) is capable of ownership, at least in the context of a claim in the tort of negligence and bailment. This article examines the various issues by reference to both English and Commonwealth authority.
Resumo:
In this paper we propose an agitation method based on megasonic acoustic streaming to overcome the limitations in plating rate and uniformity of the metal deposits during the electroplating process. Megasonic agitation at a frequency of 1 MHz allows the reduction of the thickness of the Nernst diffusion layer to less than 600 nm. Two applications that demonstrate the benefits of megasonic acoustic streaming are presented: the formation of uniform ultra-fine pitch flip-chip bumps and the metallisation of high aspect ratio microvias. For the latter application, a multi-physics based numerical simulation is implemented to describe the hydrodynamics introduced by the acoustic waves as they travel inside the deep microvias.
Resumo:
11 Å tobermorite, Ca5Si6O16(OH)2 · 4H2O, is a layer lattice ion exchange mineral whose potential as a carrier for Ag+ and Zn2+ ions in antimicrobial, bioactive formulations has not yet been explored. In view of this, the in vitro bioactivity of Ag+- and Zn2+-exchanged 11 Å tobermorites and their bactericidal action against S. aureus and P.aeruginosa are reported. The in vitro bioactivity of the synthetic unsubstituted tobermorite phase was confirmed by the formation of bone-like hydroxycarbonate apatite (HCA) on its surface within 48 h of contact with simulated body fluid. The substitution of labile Ag+ ions into the tobermorite lattice delayed the onset of HCA-formation to 72 h; whereas, the Zn2+-substituted phase failed to elicit an HCA-layer within 14 days. Both Ag+- and Zn2+-exchanged tobermorite phases were found to exhibit marked antimicrobial action against S. aureus and P.aeruginosa, two common pathogens in biomaterial-centred infections.
Resumo:
There are many factors in mucosal secretions that contribute to innate immunity and the 'first line of defence' at mucosal surfaces. Few studies, however, have investigated the effects of exercise on many of these 'defence' factors. The aim of the present study was to determine the acute effects of prolonged exercise on salivary levels of selected antimicrobial peptides (AMP) that have not yet been studied in response to exercise (HNP1-3 and LL-37) in addition to immunoglobulin A (IgA). A secondary objective was to assess the effects of exercise on saliva antibacterial capacity. Twelve active men exercised on a cycle ergometer for 2.5 h at approximately 60% of maximal oxygen uptake. Unstimulated whole saliva samples were obtained before and after exercise. There was a significant decrease (P < 0.05) in salivary IgA:osmolality ratio, following exercise, but IgA concentration and secretion rate were unaltered. Salivary HNP1-3 and LL-37 concentrations (P < 0.01 and P < 0.05, respectively), concentration:osmolality ratios (P < 0.01) and secretion rates (P < 0.01) all increased following exercise. Salivary antibacterial capacity (against E. coli) did not change. The increased concentration of AMPs in saliva may confer some benefit to the 'first line of defence' and could result from synergistic compensation within the mucosal immune system and/or airway inflammation and epithelial damage. Further study is required to determine the significance of such changes on the overall 'defence' capacity of saliva and how this influences the overall risk for infection.
Resumo:
Water retention and transport in soils is dependent upon the surface tension of the aqueous phase. Surfactants present in aqueous solution reduce the surface tension of aqueous phase. In soil–water systems, this can result in water drainage and reductions in field capacity and hydraulic conductivity. In this investigation, the surface tension of surfactant solutions mixed with soil—in a constant fixed ratio—was measured as a function of surfactant concentration. Two anionic surfactants were used: sodium dodecyl sulphate and sodium bis (2-ethylhexyl) sulfosuccinate. Two soils were also used—a clay soil and a sandy soil. The key observation made by this investigation was that the addition of soil to the surfactant solution provided a further component of surface tension reduction. Neither soil sample reduced the surface tension of water when surfactant was absent from the aqueous phase, though both soils released soil organic matter at low surfactant concentrations as shown by measurement of the chemical oxygen demand of the supernatant solutions. Furthermore, both surfactants were shown to be weakly adsorbed by soil as shown by the use of a methylene blue assay. It is therefore proposed that the additional reduction in surface tension arises from synergistic interactions between the surfactants and dissolved soil organic matter.
Resumo:
Slippage due to wall depletion effect is well-known in rheological investigation. The aim of this study was to investigate the influence of the paste microstructure on slip formation for the paste materials (lead-free solder paste and isotropic conductive adhesives). The effect of different flowgeometries, gap heights and surface roughness on the paste viscosity was investigated. The utilisation of different measuring geometries has not clearly showed the presence of wall-slip in the paste samples. The existence of wall-slip was found to be pronounced when gap heights were varied using the parallel plate geometry. It was also found that altering the surface roughness of the parallel plate measuring geometry did not significantly eliminate wall-slip as expected. But results indicate that the use of a relatively rough surface helps to increase paste adhesion to the plates and to a certain extent inducing structural breakdown in the paste. Most importantly, the study also demonstrated on how the wall-slip formation in the paste material could be utilised for understanding of the paste microstructure and its flow behaviour.
Resumo:
Solder paste is the most important strategic bonding material used in the assembly of surface mount devices in electronic industries. It is known to exhibit a thixotropic behavior, which is recognized by the decrease in apparent viscosity of paste material with time when subjected to a constant shear rate. The proper characterization of this time-dependent rheological behavior of solder pastes is crucial for establishing the relationships between the pastes structure and flow behavior; and for correlating the physical parameters with paste printing performance. In this article, we present a novel method which has been developed for characterizing the time-dependent and non-Newtonian rheological behavior of solder pastes and flux mediums as a function of shear rates. We also present results of the study of the rheology of the solder pastes and flux mediums using the structural kinetic modeling approach, which postulates that the network structure of solder pastes breaks down irreversibly under shear, leading to time and shear-dependent changes in the flow properties. Our results show that for the solder pastes used in the study, the rate and extent of thixotropy was generally found to increase with increasing shear rate. The technique demonstrated in this study has wide utility for R&D personnel involved in new paste formulation, for implementing quality control procedures used in solder-paste manufacture and packaging; and for qualifying new flip-chip assembly lines.
Resumo:
The reactions to the 9/11 terror attacks were immense in the western population. In the current review, the impact of terror attacks is presented with surveys, clinical interviews, and scientific polls, which were identified in a comprehensive literature search. Results show that the fear of further terror attacks is comparatively overestimated in the population and is associated with numerous psychological consequences and reactions. The overestimation of the probability of further terror attacks is related among other reasons to its unique features and its strong representation in the media. Several independent studies proved that the number of stress symptoms and psychiatric diagnoses is associated with a high risk perception in relation to terror attacks. This was not only the case for victims of terror attacks, but also for people indirectly exposed to the terror attacks. In addition, there is evidence that the number of the stress symptoms correlate with the duration of TV consumption of new findings about terror attempts. Methodologically, there is a critical lack of more in-depth analyses to explain the development of risk perceptions and its influence on mental and physical health. Because of the international importance and cross-cultural differences, an international standardization of research is desirable. [In German] Die Reaktionen auf die Terrorattentate vom 9. September 2001 in New York waren in der westlichen Bevölkerung immens. In der vorliegenden Übersichtsarbeit werden die Auswirkungen von Terrorattentaten durch Einbeziehung bevölkerungsrepräsentativer Untersuchungen, Surveys, klinischer Interviews und Einstellungsbefragungen dargestellt, die über eine deskriptive Literaturrecherche ermittelt wurden. Als Ergebnis des Reviews zeigt sich, dass die Angst vor weiteren Terrorattentaten in der Bevölkerung vergleichsweise hoch und mit zahlreichen psychologischen Folgen und Reaktionen assoziiert ist. Die Einschätzung der Auftretenswahrscheinlichkeit eines Terrorattentats hängt unter anderem mit den besonderen Charakteristika und der hohen medialen Präsenz des Themas zusammen. Die Anzahl der Stresssymptome bis hin zu psychiatrischen Diagnosen erwies sich in mehreren unabhängigen Untersuchungen mit einer hohen Risikowahrnehmung assoziiert. Dies ließ sich nicht nur bei den Opfern von Terrorattentaten, sondern auch bei indirekt Betroffenen zeigen. Darüber hinaus gibt es mehrfache Belege dafür, dass die Anzahl der Stresssymptome mit der Dauer des TV-Konsums über Neuigkeiten zu Terrorattentaten zusammenhing. Als methodische Kritik ist an den gegenwärtigen Untersuchungsszenarien einzuwenden, dass es derzeit keine tiefer gehenden Analysen zur Entwicklung der Risikowahrnehmung und zu ihrem Einfluss auf die Gesundheit gibt. Aufgrund der internationalen Bedeutung des Themas und der interkulturellen Unterschiede im Umgang mit Krisensituationen ist eine internationale Standardisierung von Untersuchungszugängen wünschenswert.
Resumo:
We evaluate the conditional performance of U.K. equity unit trusts using the approach of Lynch and Wachter (2007, 2008) relative to three conditional linear factor models. We find significant time variation in the conditional performance of some trust portfolios and individual trusts using the lag term spread as the information variable. The conditional performance of the trusts is countercyclical and larger trusts have more countercyclical performance than smaller trusts within certain investment sectors. These patterns in conditional trust performance cannot be fully explained by the underlying securities that the trusts hold.
Resumo:
The potential of employing zinc polycarboxylate dental cement as a controlled release material has been studied. Benzalkonium chloride was used as the active ingredient, and incorporated at concentrations of 1, 2 and 3% by mass within the cement. At these levels, there was no observable effect on the speed of setting. Release was followed using an ion-selective electrode to determine changes in chloride ion concentration with time. This technique showed that the additive was released when the cured cement was placed in water, with release occurring by a diffusion mechanism for the first 3 h, but continuing beyond that for up to 1 week. Diffusion coefficients were in the range 5.62 × 10(−6) cm(2) s(−1) (for 1% concentration) to 10.90 × 10(−6) cm(2) s(−1) (for 3% concentration). Up to 3% of the total loading of benzalkonium chloride was released from the zinc polycarboxylate after a week, which is similar to that found in previous studies with glass-ionomer cement. It is concluded that zinc polycarboxylate cement is capable of acting as a useful material for the controlled release of active organic compounds.
Resumo:
Purpose: A novel methodology has been introduced to effectively coat intravascular stents with sirolimus-loaded polymeric microparticles. Methods: Dry powders of the microparticulate formulation, consisting of non-erodible polymers, were produced by a supercritical, aerosol, solvent extraction system (ASES). A design of experiment (DOE) approach was conducted on the independent variables, such as organic/CO2 phase volume ratio, polymer weight and stirring-rate, while regression analysis was utilized to interpret the influence of all operational parameters on the dependent variable of particle size. The dry powders, so formed, entered an electric field created by corona charging and were sprayed on the earthed metal stent. Furthermore, the thermal stability of sirolimus was investigated to define the optimum conditions for fusion to the metal surfaces. Results: The electrostatic dry powder deposition technology (EDPDT) was used on the metal strut followed by fusion to produce uniform, reproducible and accurate coatings. The coated stents exhibited sustained release profiles over 25 days, similar to commercial products. EDPDT-coated stents displayed significant reduced platelet adhesion. Conclusions: EDPDT appeared to be a robust accurate and reproducible technology to coat eluting stents.