4 resultados para Benign eyelid lesion

em Greenwich Academic Literature Archive - UK


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the possibility of distinguishing between benign and malignant masses by exploiting the morphology-dependent temporal and spectral characteristics of their microwave backscatter response in ultra-wideband breast cancer detection. The spiculated border profiles of 2-D breast masses are generated by modifying the baseline elliptical rings based upon the irregularity of their peripheries. Furthermore, the single- and multilayer lesion models are used to characterize a distinct mass region followed by a sharp transition to background, and a blurred mass border exhibiting a gradual transition to background, respectively. Subsequently, the complex natural resonances (CNRs) of the backscatter microwave signature can be derived from the late-time target response and reveal diagnostically useful information. The fractional sequence CLEAN algorithm is proposed to estimate the lesions' delay intervals and identify the late-time responses. Finally, it is shown through numerical examples that the locations of dominant CNRs are dependent on the lesion morphologies, where 2-D computational breast phantoms with single and multiple lesions are investigated. The analysis is of potential use for discrimination between benign and malignant lesions, where the former usually possesses a better-defined, more compact shape as opposed to the latter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epilobium parviflorum Schreb. (Onagraceae) is used for the treatment of benign prostatic hyperplasia (BPH), but its biological action is not entirely identified. This paper aims to report data on E. parviflorum with respect to its antioxidant and antiinflammatory effects. The aqueous acetone extract of E. parviflorum showed higher antioxidant effect in the DPPH assay than well known antioxidants and inhibited the lipid peroxidation determined by the TBA assay (IC(50) = 2.37 +/- 0.12 mg/mL). In concentrations of 0.2-15.0 microg/mL the extract possessed a protective effect, comparable to catalase (250 IU/mL), against oxidative damage, generated in fibroblast cells. In the COX inhibition assay E. parviflorum decreased the PGE(2) release, so showing inhibition of the COX-enzyme (IC(50) = 1.4 +/- 0.1 microg/mL).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epilobium parviflorum Schreb. (Onagraceae) is used for the treatment of benign prostatic hyperplasia (BPH), which is regarded as an endocrine disorder caused by age-related hormone imbalance and increased oxidative damage [1,2,3]. Epilobium can moderate the obstructive and the irritative symptoms of BPH [1] but its biological action is not entirely identified. E. parviflorum is rich in phytosterols, flavonoids (myricetin, quercetin, kaempferol and their glycosides), phenolic acids, catechins, ellagi- and gallotannins [4]. The potential biological effects of Epilobium parviflorum Schreb. have been investigated, in respect to its antioxidant, anti-inflammatory, enzyme-inhibitory and anti-androgenic effect. The whole-plant water extract showed higher antioxidant effect (IC50=1.65±0.05µg/mL) in DPPH assay than Trolox or ascorbic acid and inhibited the lipid peroxidation examined in TBA assay (IC50=2.31±0.18mg/mL). In concentrations 0.20-15.00µg/mL the extract possessed a protective effect comparable to catalase enzyme (2500 IU/mL), against oxidative damage generated on fibroblast cells. The examination of the COX-inhibitory effect showed that E. parviflorum had an anti-inflammatory effect (IC50=1.38±0.08µg/mL). Investigation of steroid receptor binding ability and the aromatase enzyme-inhibition showed negative results in the concentration range examined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulse design is investigated for time-reversal (TR) imaging as applied to ultrawideband (UWB) breast cancer detection. Earlier it has been shown that a suitably-designed UWB pulse may help to improve imaging performance for a single-tumor breast phantom with predetermined lesion properties. The current work considers the following more general and practical situations: presence of multiple malignancies with unknown tumor size and dielectric properties. Four pulse selection criteria are proposed with each focusing on one of the following aspects: eliminating signal clutter generated by tissue inhomogeneities, canceling mutual interference among tumors, improving image resolution, and suppressing artifacts created by sidelobe of the target response. By applying the proposed criteria, the shape parameters of UWB waveforms with desirable characteristics are identified through search of all the possible pulses. Simulation example using a numerical breast phantom, comprised of two tumors and structured clutter distribution, demonstrates the effectiveness of the proposed approach. Specifically, a tradeoff between the image resolution and signal-to-clutter contrast (SCC) is observed in terms of selection of the excitation waveforms.