2 resultados para Article 2365 c.c.Q.

em Greenwich Academic Literature Archive - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite being exposed to the harsh sea-spray environment of the North Sea at Arbroath, Scotland, for over 63 years, many of the reinforced concrete precast beam elements of the 1.5 km long promenade railing are still in very good condition and show little evidence of reinforcement corrosion. In contrast, railing replacements constructed in about 1968 and in 1993 are almost all badly cracked as a result of extensive corrosion of the longitudinal reinforcement. This is despite the newer concrete appearing to be of better quality than the 1943 concrete. Statistics for maximum crack width for each of the three populations, based on measurements made in 2004 and in 2006, are presented. In situ and laboratory measurements show that the 1943 concrete appears to have high permeability but it also shows high electrical resistivity. Chloride penetration measurements show the 1943 and 1993 concretes to have similar chloride profiles and similar chloride concentrations at the reinforcement bars. This is inconsistent with the 1943 beams showing much less reinforcement corrosion than their later replacements and casts doubt on the conventional practice for durability design focusing on reducing concrete permeability through denser concretes or greater cover.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a practical approach for the investigation, assessment and design of existing soakaways. This method can be utilised for measuring the performance and capacity of the systems and examining whether the systems are suitable for reuse when information about the design and installation of the systems is not available. The requirements for field observations and the procedure for a soil infiltration test for the installed system are suggested for successful assessment. The soil infiltration rate of the system is estimated from the field test data without requiring information on the design and construction details of the system. The system's working condition is measured by a performance indicator related to the time taken to empty the soakaway. This is then employed to evaluate the potential reuse of the system. The system's drain capacity is determined by the design principles of current practice and the effect of climate change on its drain capacity is considered. Contamination of soils around the systems after long-term use of discharge service and the water present in soakaway chambers are also investigated. A detailed case study for the reuse of four installed soakaways for a new housing development demonstrates how the proposed approach provides a straightforward process for the infiltration performance and drain capacity assessment of the existing systems. The effectiveness and applicability of the proposed approach are further demonstrated from the assessments for a number of installed systems over various sites