2 resultados para ARM, Intensity after demagnetization
em Greenwich Academic Literature Archive - UK
Effects of exercise intensity on salivary antimicrobial proteins and markers of stress in active men
Resumo:
In the present study, we assessed the effects of exercise intensity on salivary immunoglobulin A (s-IgA) and salivary lysozyme (s-Lys) and examined how these responses were associated with salivary markers of adrenal activation. Using a randomized design, 10 healthy active men participated in three experimental cycling trials: 50% maximal oxygen uptake (VO2max), 75%VO2max, and an incremental test to exhaustion. The durations of the trials were the same as for a preliminary incremental test to exhaustion (22.3 min, sx = 0.8). Timed, unstimulated saliva samples were collected before exercise, immediately after exercise, and 1 h after exercise. In the incremental exhaustion trial, the secretion rates of both s-IgA and s-Lys were increased. An increase in s-Lys secretion rate was also observed at 75%VO2max. No significant changes in saliva flow rate were observed in any trial. Cycling at 75%VOmax and to exhaustion increased the secretion of alpha-amylase and chromogranin A immediately after exercise; higher cortisol values at 75%VO2max and in the incremental exhaustion trial compared with 50%VO2max were observed 1 h immediately after exercise only. These findings suggest that short-duration, high-intensity exercise increases the secretion rate of s-IgA and s-Lys despite no change in the saliva flow rate. These effects appear to be associated with changes in sympathetic activity and not the hypothalamic - pituitary - adrenal axis.
Resumo:
This study investigated the effect of crank configuration on muscle activity and torque production during submaximal arm crank ergometry. Thirteen non-specifically trained male participants volunteered. During the research trials they completed a warm-up at 15 W before two 3-min exercise stages were completed at 50 and 100 W; subjects used either a synchronous or asynchronous pattern of cranking. During the final 30-s of each submaximal exercise stage electromyographic and torque production data were collected. After the data had been processed each parameter was analysed using separate 2-way ANOVA tests with repeated measures. The activity of all muscles increased in line with external workload, although a shift in the temporal pattern of muscle activity was noted between crank configurations. Patterns of torque production during asynchronous and synchronous cranking were distinct. Furthermore, peak, minimum and delta (peak-minimum) torque values were different (P < 0.05) between crank configurations at both workloads. For example, at 100 W, peak torque using synchronous [19.6 (4.3) Nm] cranking was higher (P < 0.05) compared to asynchronous [16.8 (1.6) Nm] cranking. In contrast minimum torque was lower (P < 0.05) at 100 W using synchronous [4.8 (1.7) Nm] compared to asynchronous [7.3 (1.2) Nm] cranking. There was a distinct bilateral asymmetry in torque production during asynchronous cranking with the dominant transmitting significantly more force to the crank arm. Taken together, these preliminary data demonstrate the complex nature of muscle activity during arm crank ergometry performed with an asynchronous or synchronous crank set-up. Further work is required to determine how muscle activity (EMG activity) and associated patterns of torque production influence physiological responses and functional capacity during arm crank ergometry.