67 resultados para Mather, Edwin J.
Resumo:
The amount of atmospheric hydrogen chloride (HCl) within fire enclosures produced from the combustion of chloride-based materials tends to decay as the fire effluent is transported through the enclosure due to mixing with fresh air and absorption by solids. This paper describes an HCl decay model, typically used in zone models, which has been modified and applied to a computational fluid dynamics (CFD)-based fire field model. While the modified model still makes use of some empirical formulations to represent the deposition mechanisms, these have been reduced from the original three to two through the use of the CFD framework. Furthermore, the effect of HCl flow to the wall surfaces on the time to reach equilibrium between HCl in the boundary layer and on wall surfaces is addressed by the modified model. Simulation results using the modified HCl decay model are compared with data from three experiments. The model is found to be able to reproduce the experimental trends and the predicted HCl levels are in good agreement with measured values
Resumo:
Full-scale furnished cabin fires have been studied experimentally for the purpose of characterising the post-crash cabin fire environment by the US Federal Aviation Administration for many years. In this paper the Computational Fluid Dynamics fire field model SMARTFIRE is used to simulate one of these fires conducted in the C-133 test facility in order to provide further validation of the computational approach and the SMARTFIRE software. The experiment involves exposing the interior cabin materials to an external fuel fire, opening only one exit at the far end of the cabin (the same side as the rupture) for ventilation, and noting the subsequent spread of the external fire to the cabin interior and the onset of flashover at approximately 210 seconds. Through this analysis, the software is shown to be in good agreement with the experimental data, producing reasonable agreement with the fire dynamics prior to flashover and producing a reasonable prediction of the flashover time i.e. 225 seconds. The paper then proceeds to utilize the model to examine the impact on flashover time of the extent of cabin furnishings and cabin ventilation provided by available exits
Resumo:
Two evacuation trials were conducted within Brazilian library facilities by FSEG staff in January 2005. These trials represent one of the first such trials conducted in Brazil. The purpose of these evacuation trials was to collect pre-evacuation time data from a population with a cultural background different to that found in western Europe. In total some 34 pre-evacuation times were collected from the experiments and these ranged from 5 to 98 seconds with a mean pre-evacuation time of 46.7 seconds
Resumo:
This paper examines the influence of exit availability on evacuation time for a narrow body aircraft under certification trial conditions using computer simulation. A narrow body aircraft which has previously passed the certification trial is used as the test configuration. While maintaining the certification requirement of 50% of the available exits, six different exit configurations are examined. These include the standard certification configuration (one exit from each exit pair) and five other exit configurations based on commonly occurring exit combinations found in accidents. These configurations are based on data derived from the AASK database and the evacuation simulations are performed using the airEXODUS evacuation simulation software. The results show that the certification practice of using half the available exits predominately down one side of the aircraft is neither statistically relevant nor challenging. For the aircraft cabin layout examined, the exit configuration used in certification trial produces the shortest egress times. Furthermore, three of the six exit combinations investigated result in predicted egress times in excess of 90 seconds, suggesting that the aircraft would not satisfy the certification requirement under these conditions.
Resumo:
The SMARTFIRE Computational Fluid Dynamics (CFD) fire field model has successfully reproduced the observed characteristics including measured temperatures, species concentrations and time to flashover for a post-crash fire experiment conducted by the FAA within their C-133 cabin test facility. In this test only one exit was open in order to provide ventilation for the developing cabin fire. In real post-crash fires, many exits are likely to be open as passangers attempt to evacuate. In this paper, the likely impacts on evacuation of a post-crash fire in which various exiting combinations are available are investigated. The fire scenario, investigated using the SMARTFIRE software, is based on the C-133 experiment but with a fully furnished cabin and with four different exit availability options. The fire data is imported into the airEXODUS evacuation simulation software and the resulting evacuations examined. The combined fire and evacuation analysis reveals that even though the aircraft configuration is predicted to comfortably satisfy the evacuation certification requirement, when fire is included, a number of casualties result, even from the certification compliant exit configuration.
Resumo:
In this paper, coupled fire and evacuation simulation tools are used to simulate the Station Nightclub fire. This study differs from the analysis conducted by NIST in three key areas; (1)an enhanced flame spread model and (2)a toxicity generation model are used, (3)the evacuation is coupled to the fire simulation. Predicted early burning locations in the full-scale fire simulation are in line with photographic evidence and the predicted onset of flashover is similar to that produced by NIST. However, it is suggested that both predictions of the flashover time are approximately 15 sec earlier than actually occurred. Three evacuation scenarios are then considered, two of which are coupled with the fire simulation. The coupled fire and evacuation simulation suggests that 180 fatalities result from a building population of 460. With a 15 sec delay in the fire timeline, the evacuation simulation produces 84 fatalities which are in good agreement with actual number of fatalities. An important observation resulting from this work is that traditional fire engineering ASET/RSET calculations which do not couple the fire and evacuation simulations have the potential to be considerably over optimistic in terms of the level of safety achieved by building designs.
Resumo:
This paper describes the introduction of chained signage systems into evacuation simulation models. Signage systems are widely used in buildings to provide information for wayfinding, thereby providing exiting information during emergencies and assisting in navigation during normal circulation of pedestrians. Recently a system was developed to introduce simple signs into egress models. The system, known as Visibility Catchment Area or VCA, allowed similated agents to interact with signs which point directly to an exit and signs which are located directly above the exit. However, this approach was not able to represent the more general situation of a sign netwokr within an arbitrarily complex building. In this paper we extend the method to include chained signage systems which provides simulated agents that are unfamiliar with the structure a means by which to navigate to an emergency exit. The model includes the associated navigation behaviours exhibited by occupants that rely on a signage system for navigation including: Searching behaviours, Backtracking behaviours, Lost behaviours and Communication behaviours. The new features are demonstrated through a series of demonstration cases and are shown to produce plausible results.
Resumo:
This paper briefly describes the methodologies employed in the collection and storage of first-hand accounts of evacuation experiences derived from face-to-face interviews with evacuees from the World Trade Center (WTC) Twin Towers complex on 11 September 2001 and the development of the High-rise Evacuation Evaluation Database (HEED). The main focus of the paper is to present an overview of preliminary analysis of data derived from the evacuation of the North Tower.
Resumo:
This paper presents a description of a new agent based elevator sub-model developed as part of the buildingEXODUS software intended for both evacuation and circulation applications. A description of each component of the newly developed model is presented, including the elevator kinematics and associated pedestrian behaviour. The elevator model is then used to investigate a series of full building evacuation scenarios based on a hypothetical 50 floor building with four staircases and a population of 7,840 agents. The analysis explores the relative merits of using up to 32 elevators (arranged in four banks) and various egress strategies to evacuate the entire building population. Findings from the investigation suggest that the most efficient evacuation strategy utilises a combination of elevators and stairs to empty the building and clear the upper half of the building in minimum time. Combined stair elevator evacuation times have been shown to be as much as 50% faster than stair only evacuation times.
Resumo:
This paper presents data relating to pedestrian escalator behaviour collected in an underground station in Shanghai, China. While data was not collected under emergency or simulated emergency conditions, it is argued that the data collected under rush-hour conditions - where commuters are under time pressures to get to work on time - may be used to approximate emergency evacuation conditions - where commuters are also under time pressures to exit the building as quickly as possible. Data pertaining to escalator/stair choice, proportion of walkers to riders, walker speeds and side usage are presented. The collected data is used to refine the buildingEXODUS escalator model allowing the agents to select whether to use an escalator or neighbouring parallel stair based on congestion conditiions at the base of the stair/escalator and expected travel times. The new model, together with the collected data, is used to simulate a series of hypothetical evacuation scenarios to demonstrate the impact of escalators on evacuation performance.
Resumo:
Signage systems play an important role in aiding occupants during both circulation and evacuation. Despite the fact that signage systems are an important component in building wayfinding systems, there is a lack of relevant data regarding how occupants detect, interpret and use the information conveyed by emergency signage. The effectiveness of signage systems is therefore difficult to assess. In this paper we address this issue through experimentation. The experiment involved measuring the impact of a signage system on a population of 68 test subjects who were instructed to individually vacate a building as quickly as possible via any means they thought appropriate. The evacuation path involved a number of decision points at which emergency signage was available to identify the appropriate path. Through analysis of video footage and data derived from questionnaires, the number of people who saw and utilised the signage information to assist their egress is determined. The results are then incorporated within the buildingEXODUS software and used in a demonstration of agent interaction with signage systems in a hypothetical evacuation scenario.
Resumo:
This paper presents results from a questionnaire study of participant exit awareness and suggested exit selection in the event of emergency evacuations involving narrow body aircraft. The study involved 459 participants with varying flight experience. The results of this study supports the hypothesis that poor understanding by passengers of aircraft exit location and configuration may be a contributory factor in the resulting poor exit selection decisions made by passengers in emergency situations. These results have important safety implications for airlines and also provide important insight to evacuation model developers regarding the decision making process in agent exit selection.
Resumo:
Within the building evacuation context, wayfinding describes the process in which an individual located within an arbitrarily complex enclosure attempts to find a path which leads them to relative safety, usually the exterior of the enclosure. Within most evacuation modelling tools, wayfinding is completely ignored; agents are either assigned the shortest distance path or use a potential field to find the shortest path to the exits. In this paper a novel wayfinding technique that attempts to represent the manner in which people wayfind within structures is introduced and demonstrated through two examples. The first step is to encode the spatial information of the enclosure in terms of a graph. The second step is to apply search algorithms to the graph to find possible routes to the destination and assign a cost to the routes based on their personal route preferences such as "least time" or "least distance" or a combination of criteria. The third step is the route execution and refinement. In this step, the agent moves along the chosen route and reassesses the route at regular intervals and may decide to take an alternative path if the agent determines that an alternate route is more favourable e.g. initial path is highly congested or is blocked due to fire.