2 resultados para run length

em Duke University


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: There are two goals of this study. The first goal of this study is to investigate the feasibility of using classic textural feature extraction in radiotherapy response assessment among a unique cohort of early stage breast cancer patients who received the single-dose preoperative radiotherapy. The second goal of this study is to investigate the clinical feasibility of using classic texture features as potential biomarkers which are supplementary to regional apparent diffusion coefficient in gynecological cancer radiotherapy response assessment.

Methods and Materials: For the breast cancer study, 15 patients with early stage breast cancer were enrolled in this retrospective study. Each patient received a single-fraction radiation treatment, and DWI and DCE-MRI scans were conducted before and after the radiotherapy. DWI scans were acquired using a spin-echo EPI sequence with diffusion weighting factors of b = 0 and b = 500 mm2/s, and the apparent diffusion coefficient (ADC) maps were calculated. DCE-MRI scans were acquired using a T1-weighted 3D SPGR sequence with a temporal resolution of about 1 minute. The contrast agent (CA) was intravenously injected with a 0.1 mmol/kg bodyweight dose at 2 ml/s. Two parameters, volume transfer constant (Ktrans) and kep were analyzed using the two-compartment Tofts pharmacokinetic model. For pharmacokinetic parametric maps and ADC maps, 33 textural features were generated from the clinical target volume (CTV) in a 3D fashion using the classic gray level co-occurrence matrix (GLCOM) and gray level run length matrix (GLRLM). Wilcoxon signed-rank test was used to determine the significance of each texture feature’s change after the radiotherapy. The significance was set to 0.05 with Bonferroni correction.

For the gynecological cancer study, 12 female patients with gynecologic cancer treated with fractionated external beam radiotherapy (EBRT) combined with high dose rate (HDR) intracavitary brachytherapy were studied. Each patient first received EBRT treatment followed by five fractions of HDR treatment. Before EBRT and before each fraction of brachytherapy, Diffusion Weighted MRI (DWI-MRI) and CT scans were acquired. DWI scans were acquired in sagittal plane utilizing a spin-echo echo-planar imaging sequence with weighting factors of b = 500 s/mm2 and b = 1000 s/mm2, one set of images of b = 0 s/mm2 were also acquired. ADC maps were calculated using linear least-square fitting method. Distributed diffusion coefficient (DDC) maps and stretching parameter α were calculated. For ADC and DDC maps, 33 classic texture features were generated utilizing the classic gray level run length matrix (GLRLM) and gray level co-occurrence matrix (GLCOM) from high-risk clinical target volume (HR-CTV). Wilcoxon signed-rank statistics test was applied to determine the significance of each feature’s numerical value change after radiotherapy. Significance level was set to 0.05 with multi-comparison correction if applicable.

Results: For the breast cancer study, regarding ADC maps calculated from DWI-MRI, 24 out of 33 CTV features changed significantly after the radiotherapy. For DCE-MRI pharmacokinetic parameters, all 33 CTV features of Ktrans and 33 features of kep changed significantly.

For the gynecological cancer study, regarding ADC maps, 28 out of 33 HR-CTV texture features showed significant changes after the EBRT treatment. 28 out of 33 HR-CTV texture features indicated significant changes after HDR treatments. The texture features that indicated significant changes after HDR treatments are the same as those after EBRT treatment. 28 out of 33 HR-CTV texture features showed significant changes after whole radiotherapy treatment process. The texture features that indicated significant changes for the whole treatment process are the same as those after HDR treatments.

Conclusion: Initial results indicate that certain classic texture features are sensitive to radiation-induced changes. Classic texture features with significant numerical changes can be used in monitoring radiotherapy effect. This might suggest that certain texture features might be used as biomarkers which are supplementary to ADC and DDC for assessment of radiotherapy response in breast cancer and gynecological cancer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Backscatter communication is an emerging wireless technology that recently has gained an increase in attention from both academic and industry circles. The key innovation of the technology is the ability of ultra-low power devices to utilize nearby existing radio signals to communicate. As there is no need to generate their own energetic radio signal, the devices can benefit from a simple design, are very inexpensive and are extremely energy efficient compared with traditional wireless communication. These benefits have made backscatter communication a desirable candidate for distributed wireless sensor network applications with energy constraints.

The backscatter channel presents a unique set of challenges. Unlike a conventional one-way communication (in which the information source is also the energy source), the backscatter channel experiences strong self-interference and spread Doppler clutter that mask the information-bearing (modulated) signal scattered from the device. Both of these sources of interference arise from the scattering of the transmitted signal off of objects, both stationary and moving, in the environment. Additionally, the measurement of the location of the backscatter device is negatively affected by both the clutter and the modulation of the signal return.

This work proposes a channel coding framework for the backscatter channel consisting of a bi-static transmitter/receiver pair and a quasi-cooperative transponder. It proposes to use run-length limited coding to mitigate the background self-interference and spread-Doppler clutter with only a small decrease in communication rate. The proposed method applies to both binary phase-shift keying (BPSK) and quadrature-amplitude modulation (QAM) scheme and provides an increase in rate by up to a factor of two compared with previous methods.

Additionally, this work analyzes the use of frequency modulation and bi-phase waveform coding for the transmitted (interrogating) waveform for high precision range estimation of the transponder location. Compared to previous methods, optimal lower range sidelobes are achieved. Moreover, since both the transmitted (interrogating) waveform coding and transponder communication coding result in instantaneous phase modulation of the signal, cross-interference between localization and communication tasks exists. Phase discriminating algorithm is proposed to make it possible to separate the waveform coding from the communication coding, upon reception, and achieve localization with increased signal energy by up to 3 dB compared with previous reported results.

The joint communication-localization framework also enables a low-complexity receiver design because the same radio is used both for localization and communication.

Simulations comparing the performance of different codes corroborate the theoretical results and offer possible trade-off between information rate and clutter mitigation as well as a trade-off between choice of waveform-channel coding pairs. Experimental results from a brass-board microwave system in an indoor environment are also presented and discussed.