2 resultados para mixed-signal design
em Duke University
Resumo:
INTRODUCTION: Adherence to glaucoma medications is essential for successful treatment of the disease but is complex and difficult for many of our patients. Health coaching has been used successfully in the treatment of other chronic diseases. This pilot study explores the use of health coaching for glaucoma care. METHODS: A mixed methods study design was used to assess the health coaching intervention for glaucoma patients. The health coaching intervention consisted of four to six health coaching sessions with a certified health coach via telephone. Quantitative measures included demographic and health information, adherence to glaucoma medications (using the visual analog adherence scale and medication event monitoring system), and an exit survey rating the experience. Qualitative measures included a precoaching health questionnaire, notes made by the coach during the intervention, and an exit interview with the subjects at the end of the study. RESULTS: Four glaucoma patients participated in the study; all derived benefits from the health coaching. Study subjects demonstrated increased glaucoma drop adherence in response to the coaching intervention, in both visual analog scale and medication event monitoring system. Study subjects' qualitative feedback reflected a perceived improvement in both eye and general health self-care. The subjects stated that they would recommend health coaching to friends or family members. CONCLUSION: Health coaching was helpful to the glaucoma patients in this study; it has the potential to improve glaucoma care and overall health.
Resumo:
Magnetic field inhomogeneity results in image artifacts including signal loss, image blurring and distortions, leading to decreased diagnostic accuracy. Conventional multi-coil (MC) shimming method employs both RF coils and shimming coils, whose mutual interference induces a tradeoff between RF signal-to-noise (SNR) ratio and shimming performance. To address this issue, RF coils were integrated with direct-current (DC) shim coils to shim field inhomogeneity while concurrently emitting and receiving RF signal without being blocked by the shim coils. The currents applied to the new coils, termed iPRES (integrated parallel reception, excitation and shimming), were optimized in the numerical simulation to improve the shimming performance. The objectives of this work is to offer a guideline for designing the optimal iPRES coil arrays to shim the abdomen.
In this thesis work, the main field () inhomogeneity was evaluated by root mean square error (RMSE). To investigate the shimming abilities of iPRES coil arrays, a set of the human abdomen MRI data was collected for the numerical simulations. Thereafter, different simplified iPRES(N) coil arrays were numerically modeled, including a 1-channel iPRES coil and 8-channel iPRES coil arrays. For 8-channel iPRES coil arrays, each RF coil was split into smaller DC loops in the x, y and z direction to provide extra shimming freedom. Additionally, the number of DC loops in a RF coil was increased from 1 to 5 to find the optimal divisions in z direction. Furthermore, switches were numerically implemented into iPRES coils to reduce the number of power supplies while still providing similar shimming performance with equivalent iPRES coil arrays.
The optimizations demonstrate that the shimming ability of an iPRES coil array increases with number of DC loops per RF coil. Furthermore, the z direction divisions tend to be more effective in reducing field inhomogeneity than the x and y divisions. Moreover, the shimming performance of an iPRES coil array gradually reach to a saturation level when the number of DC loops per RF coil is large enough. Finally, when switches were numerically implemented in the iPRES(4) coil array, the number of power supplies can be reduced from 32 to 8 while keeping the shimming performance similar to iPRES(3) and better than iPRES(1). This thesis work offers a guidance for the designs of iPRES coil arrays.