22 resultados para individual interest

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use information from the television game show with the highest guaranteed average payoff in the United States, Hoosier Millionaire, to analyze risktaking in a high-stakes experiment. We characterize gambling decisions under alternative assumptions about contestant behavior and preferences, and derive testable restrictions on individual risk attitudes based on this characterization. We then use an extensive sample of gambling decisions to estimate distributions of risk-aversion parameters consistent with the theoretical restrictions and revealed preferences. We find that although most contestants display risk-averse preferences, the extent of the risk aversion implied by our estimates varies substantially with the stakes involved in the different decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a scalable approach to addressing multiple atomic qubits for use in quantum information processing. Individually trapped 87Rb atoms in a linear array are selectively manipulated with a single laser guided by a microelectromechanical beam steering system. Single qubit oscillations are shown on multiple sites at frequencies of ≃3.5 MHz with negligible crosstalk to neighboring sites. Switching times between the central atom and its closest neighbor were measured to be 6-7 μs while moving between the central atom and an atom two trap sites away took 10-14 μs. © 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Focal therapy (FT) for the management of clinically localized prostate cancer (PCa) is growing from a concept to reality because of increased interest of both patients and physicians. Selection protocols, however, are yet to be established. We discuss the role of prostate biopsy in candidate selection for FT and highlight the different strategies and technical aspects of the use of prostate biopsy in this setting. In our opinion, prostate biopsy plays a major role in the selection process and tailoring appropriate treatment strategy to the patient. FT necessitates dedicated biopsy schemes that would reliably predict the extent, nature, and location of PCa in selected patients. Currently, there is insufficient scientific evidence to propose a specific biopsy scheme that could fit every candidate, providing accurate characterization of the disease in the individual patient. Further research is necessary to establish solid selection protocols that would reliably identify appropriate candidates for FT of PCa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The Veterans Health Administration has developed My HealtheVet (MHV), a Web-based portal that links veterans to their care in the veteran affairs (VA) system. The objective of this study was to measure diabetic veterans' access to and use of the Internet, and their interest in using MHV to help manage their diabetes. MATERIALS AND METHODS: Cross-sectional mailed survey of 201 patients with type 2 diabetes and hemoglobin A(1c) > 8.0% receiving primary care at any of five primary care clinic sites affiliated with a VA tertiary care facility. Main measures included Internet usage, access, and attitudes; computer skills; interest in using the Internet; awareness of and attitudes toward MHV; demographics; and socioeconomic status. RESULTS: A majority of respondents reported having access to the Internet at home. Nearly half of all respondents had searched online for information about diabetes, including some who did not have home Internet access. More than a third obtained "some" or "a lot" of their health-related information online. Forty-one percent reported being "very interested" in using MHV to help track their home blood glucose readings, a third of whom did not have home Internet access. Factors associated with being "very interested" were as follows: having access to the Internet at home (p < 0.001), "a lot/some" trust in the Internet as a source of health information (p = 0.002), lower age (p = 0.03), and some college (p = 0.04). Neither race (p = 0.44) nor income (p = 0.25) was significantly associated with interest in MHV. CONCLUSIONS: This study found that a diverse sample of older VA patients with sub-optimally controlled diabetes had a level of familiarity with and access to the Internet comparable to an age-matched national sample. In addition, there was a high degree of interest in using the Internet to help manage their diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Stroke is one of the most disabling and costly impairments of adulthood in the United States. Stroke patients clearly benefit from intensive inpatient care, but due to the high cost, there is considerable interest in implementing interventions to reduce hospital lengths of stay. Early discharge rehabilitation programs require coordinated, well-organized home-based rehabilitation, yet lack of sufficient information about the home setting impedes successful rehabilitation. This trial examines a multifaceted telerehabilitation (TR) intervention that uses telehealth technology to simultaneously evaluate the home environment, assess the patient's mobility skills, initiate rehabilitative treatment, prescribe exercises tailored for stroke patients and provide periodic goal oriented reassessment, feedback and encouragement. METHODS: We describe an ongoing Phase II, 2-arm, 3-site randomized controlled trial (RCT) that determines primarily the effect of TR on physical function and secondarily the effect on disability, falls-related self-efficacy, and patient satisfaction. Fifty participants with a diagnosis of ischemic or hemorrhagic stroke will be randomly assigned to one of two groups: (a) TR; or (b) Usual Care. The TR intervention uses a combination of three videotaped visits and five telephone calls, an in-home messaging device, and additional telephonic contact as needed over a 3-month study period, to provide a progressive rehabilitative intervention with a treatment goal of safe functional mobility of the individual within an accessible home environment. Dependent variables will be measured at baseline, 3-, and 6-months and analyzed with a linear mixed-effects model across all time points. DISCUSSION: For patients recovering from stroke, the use of TR to provide home assessments and follow-up training in prescribed equipment has the potential to effectively supplement existing home health services, assist transition to home and increase efficiency. This may be particularly relevant when patients live in remote locations, as is the case for many veterans. TRIAL REGISTRATION: Clinical Trials.gov Identifier: NCT00384748.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: There is considerable interest in the development of methods to efficiently identify all coding variants present in large sample sets of humans. There are three approaches possible: whole-genome sequencing, whole-exome sequencing using exon capture methods, and RNA-Seq. While whole-genome sequencing is the most complete, it remains sufficiently expensive that cost effective alternatives are important. RESULTS: Here we provide a systematic exploration of how well RNA-Seq can identify human coding variants by comparing variants identified through high coverage whole-genome sequencing to those identified by high coverage RNA-Seq in the same individual. This comparison allowed us to directly evaluate the sensitivity and specificity of RNA-Seq in identifying coding variants, and to evaluate how key parameters such as the degree of coverage and the expression levels of genes interact to influence performance. We find that although only 40% of exonic variants identified by whole genome sequencing were captured using RNA-Seq; this number rose to 81% when concentrating on genes known to be well-expressed in the source tissue. We also find that a high false positive rate can be problematic when working with RNA-Seq data, especially at higher levels of coverage. CONCLUSIONS: We conclude that as long as a tissue relevant to the trait under study is available and suitable quality control screens are implemented, RNA-Seq is a fast and inexpensive alternative approach for finding coding variants in genes with sufficiently high expression levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Disclosure of authors' financial interests has been proposed as a strategy for protecting the integrity of the biomedical literature. We examined whether authors' financial interests were disclosed consistently in articles on coronary stents published in 2006. METHODOLOGY/PRINCIPAL FINDINGS: We searched PubMed for English-language articles published in 2006 that provided evidence or guidance regarding the use of coronary artery stents. We recorded article characteristics, including information about authors' financial disclosures. The main outcome measures were the prevalence, nature, and consistency of financial disclosures. There were 746 articles, 2985 authors, and 135 journals in the database. Eighty-three percent of the articles did not contain disclosure statements for any author (including declarations of no interests). Only 6% of authors had an article with a disclosure statement. In comparisons between articles by the same author, the types of disagreement were as follows: no disclosure statements vs declarations of no interests (64%); specific disclosures vs no disclosure statements (34%); and specific disclosures vs declarations of no interests (2%). Among the 75 authors who disclosed at least 1 relationship with an organization, there were 2 cases (3%) in which the organization was disclosed in every article the author wrote. CONCLUSIONS/SIGNIFICANCE: In the rare instances when financial interests were disclosed, they were not disclosed consistently, suggesting that there are problems with transparency in an area of the literature that has important implications for patient care. Our findings suggest that the inconsistencies we observed are due to both the policies of journals and the behavior of some authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that "commodity currency" exchange rates have surprisingly robust power in predicting global commodity prices, both in-sample and out-of-sample, and against a variety of alternative benchmarks. This result is of particular interest to policy makers, given the lack of deep forward markets in many individual commodities, and broad aggregate commodity indices in particular. We also explore the reverse relationship (commodity prices forecasting exchange rates) but find it to be notably less robust. We offer a theoretical resolution, based on the fact that exchange rates are strongly forward-looking, whereas commodity price fluctuations are typically more sensitive to short-term demand imbalances. © 2010 by the President and Fellows of Harvard College and the Massachusetts Institute of Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the applicability of the present-value asset pricing model to fishing quota markets by applying instrumental variable panel data estimation techniques to 15 years of market transactions from New Zealand's individual transferable quota (ITQ) market. In addition to the influence of current fishing rents, we explore the effect of market interest rates, risk, and expected changes in future rents on quota asset prices. The results indicate that quota asset prices are positively related to declines in interest rates, lower levels of risk, expected increases in future fish prices, and expected cost reductions from rationalization under the quota system. © 2007 American Agricultural Economics Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Addressing global fisheries overexploitation requires better understanding of how small-scale fishing communities in developing countries limit access to fishing grounds. We analyze the performance of a system based on individual licenses and a common property-rights regime in their ability to generate incentives for self-governance and conservation of fishery resources. Using a qualitative before-after-control-impact approach, we compare two neighbouring fishing communities in the Gulf of California, Mexico. Both were initially governed by the same permit system, are situated in the same ecosystem, use similar harvesting technology, and have overharvested similar species. One community changed to a common property-right regime, enabling the emergence of access controls and avoiding overexploitation of benthic resources, while the other community, still relies on the permit system. We discuss the roles played by power, institutions, socio-historic, and biophysical factors to develop access controls. © 2012 The Author(s).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical factors play a crucial role in the development of articular cartilage in vivo. In this regard, tissue engineers have sought to leverage native mechanotransduction pathways to enhance in vitro stem cell-based cartilage repair strategies. However, a thorough understanding of how individual mechanical factors influence stem cell fate is needed to predictably and effectively utilize this strategy of mechanically-induced chondrogenesis. This article summarizes some of the latest findings on mechanically stimulated chondrogenesis, highlighting several new areas of interest, such as the effects of mechanical stimulation on matrix maintenance and terminal differentiation, as well as the use of multifactorial bioreactors. Additionally, the roles of individual biophysical factors, such as hydrostatic or osmotic pressure, are examined in light of their potential to induce mesenchymal stem cell chondrogenesis. An improved understanding of biomechanically-driven tissue development and maturation of stem cell-based cartilage replacements will hopefully lead to the development of cell-based therapies for cartilage degeneration and disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Governments across the globe have squandered treasure and imprisoned millions of their own citizens by criminalising the use and sale of recreational drugs. But use of these drugs has remained relatively constant, and the primary victims are the users themselves. Meanwhile, antimicrobial drugs that once had the power to cure infections are losing their ability to do so, compromising the health of people around the world. The thesis of this essay is that policymakers should stop wasting resources trying to fight an unwinnable and morally dubious war against recreational drug users, and start shifting their attention to the serious threat posed by our collective misuse of antibiotics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On-board image guidance, such as cone-beam CT (CBCT) and kV/MV 2D imaging, is essential in many radiation therapy procedures, such as intensity modulated radiotherapy (IMRT) and stereotactic body radiation therapy (SBRT). These imaging techniques provide predominantly anatomical information for treatment planning and target localization. Recently, studies have shown that treatment planning based on functional and molecular information about the tumor and surrounding tissue could potentially improve the effectiveness of radiation therapy. However, current on-board imaging systems are limited in their functional and molecular imaging capability. Single Photon Emission Computed Tomography (SPECT) is a candidate to achieve on-board functional and molecular imaging. Traditional SPECT systems typically take 20 minutes or more for a scan, which is too long for on-board imaging. A robotic multi-pinhole SPECT system was proposed in this dissertation to provide shorter imaging time by using a robotic arm to maneuver the multi-pinhole SPECT system around the patient in position for radiation therapy.

A 49-pinhole collimated SPECT detector and its shielding were designed and simulated in this work using the computer-aided design (CAD) software. The trajectories of robotic arm about the patient, treatment table and gantry in the radiation therapy room and several detector assemblies such as parallel holes, single pinhole and 49 pinholes collimated detector were investigated. The rail mounted system was designed to enable a full range of detector positions and orientations to various crucial treatment sites including head and torso, while avoiding collision with linear accelerator (LINAC), patient table and patient.

An alignment method was developed in this work to calibrate the on-board robotic SPECT to the LINAC coordinate frame and to the coordinate frames of other on-board imaging systems such as CBCT. This alignment method utilizes line sources and one pinhole projection of these line sources. The model consists of multiple alignment parameters which maps line sources in 3-dimensional (3D) space to their 2-dimensional (2D) projections on the SPECT detector. Computer-simulation studies and experimental evaluations were performed as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise and acquisition geometry. In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, the six alignment parameters (3 translational and 3 rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by Radon transform, the estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution and detector acquisition geometry. The estimation accuracy was significantly improved by using 4 line sources rather than 3 and also by using thinner line-source projections (obtained by better intrinsic detector resolution). With 5 line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.

Simulation studies were performed to investigate the improvement of imaging sensitivity and accuracy of hot sphere localization for breast imaging of patients in prone position. A 3D XCAT phantom was simulated in the prone position with nine hot spheres of 10 mm diameter added in the left breast. A no-treatment-table case and two commercial prone breast boards, 7 and 24 cm thick, were simulated. Different pinhole focal lengths were assessed for root-mean-square-error (RMSE). The pinhole focal lengths resulting in the lowest RMSE values were 12 cm, 18 cm and 21 cm for no table, thin board, and thick board, respectively. In both no table and thin board cases, all 9 hot spheres were easily visualized above background with 4-minute scans utilizing the 49-pinhole SPECT system while seven of nine hot spheres were visible with the thick board. In comparison with parallel-hole system, our 49-pinhole system shows reduction in noise and bias under these simulation cases. These results correspond to smaller radii of rotation for no-table case and thinner prone board. Similarly, localization accuracy with the 49-pinhole system was significantly better than with the parallel-hole system for both the thin and thick prone boards. Median localization errors for the 49-pinhole system with the thin board were less than 3 mm for 5 of 9 hot spheres, and less than 6 mm for the other 4 hot spheres. Median localization errors of 49-pinhole system with the thick board were less than 4 mm for 5 of 9 hot spheres, and less than 8 mm for the other 4 hot spheres.

Besides prone breast imaging, respiratory-gated region-of-interest (ROI) imaging of lung tumor was also investigated. A simulation study was conducted on the potential of multi-pinhole, region-of-interest (ROI) SPECT to alleviate noise effects associated with respiratory-gated SPECT imaging of the thorax. Two 4D XCAT digital phantoms were constructed, with either a 10 mm or 20 mm diameter tumor added in the right lung. The maximum diaphragm motion was 2 cm (for 10 mm tumor) or 4 cm (for 20 mm tumor) in superior-inferior direction and 1.2 cm in anterior-posterior direction. Projections were simulated with a 4-minute acquisition time (40 seconds per each of 6 gates) using either the ROI SPECT system (49-pinhole) or reference single and dual conventional broad cross-section, parallel-hole collimated SPECT. The SPECT images were reconstructed using OSEM with up to 6 iterations. Images were evaluated as a function of gate by profiles, noise versus bias curves, and a numerical observer performing a forced-choice localization task. Even for the 20 mm tumor, the 49-pinhole imaging ROI was found sufficient to encompass fully usual clinical ranges of diaphragm motion. Averaged over the 6 gates, noise at iteration 6 of 49-pinhole ROI imaging (10.9 µCi/ml) was approximately comparable to noise at iteration 2 of the two dual and single parallel-hole, broad cross-section systems (12.4 µCi/ml and 13.8 µCi/ml, respectively). Corresponding biases were much lower for the 49-pinhole ROI system (3.8 µCi/ml), versus 6.2 µCi/ml and 6.5 µCi/ml for the dual and single parallel-hole systems, respectively. Median localization errors averaged over 6 gates, for the 10 mm and 20 mm tumors respectively, were 1.6 mm and 0.5 mm using the ROI imaging system and 6.6 mm and 2.3 mm using the dual parallel-hole, broad cross-section system. The results demonstrate substantially improved imaging via ROI methods. One important application may be gated imaging of patients in position for radiation therapy.

A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150-L110 robot). An imaging study was performed with a phantom (PET CT PhantomTM), which includes 5 spheres of 10, 13, 17, 22 and 28 mm in diameter. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single-pinhole collimator both without background in the phantom, and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180 degrees and 228 degrees respectively. The pinhole detector viewed a 14.7 cm-diameter common volume which encompassed the 28 mm and 22 mm spheres. The common volume for parallel-hole was a 20.8-cm-diameter cylinder which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the flat-top table while avoiding collision with the table and maintaining the closest possible proximity to the common volume. For image reconstruction, detector trajectories were described by radius-of-rotation and detector rotation angle θ. These reconstruction parameters were obtained from the robot base and tool coordinates. The robotic SPECT system was able to maneuver the parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector to center-of-rotation (COR) distance. In no background case, all five spheres were visible in the reconstructed parallel-hole and pinhole images. In with background case, three spheres of 17, 22 and 28 mm diameter were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameter) were readily observed in the pinhole ROI imaging.

In conclusion, the proposed on-board robotic SPECT can be aligned to LINAC/CBCT with a single pinhole projection of the line-source phantom. Alignment parameters can be estimated using one pinhole projection of line sources. This alignment method may be important for multi-pinhole SPECT, where relative pinhole alignment may vary during rotation. For single pinhole and multi-pinhole SPECT imaging onboard radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC. In simulation studies of prone breast imaging and respiratory-gated lung imaging, the 49-pinhole detector showed better tumor contrast recovery and localization in a 4-minute scan compared to parallel-hole detector. On-board SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Professionalism has been an important tenet of medical education, yet defining it is a challenge. Perceptions of professional behavior may vary by individual, medical specialty, demographic group and institution. Understanding these differences should help institutions better clarify professionalism expectations and provide standards with which to evaluate resident behavior. METHODS: Duke University Hospital and Vidant Medical Center/East Carolina University surveyed entering PGY1 residents. Residents were queried on two issues: their perception of the professionalism of 46 specific behaviors related to training and patient care; and their own participation in those specified behaviors. The study reports data analyses for gender and institution based upon survey results in 2009 and 2010. The study received approval by the Institutional Review Boards of both institutions. RESULTS: 76% (375) of 495 PGY1 residents surveyed in 2009 and 2010 responded. A majority of responders rated all 46 specified behaviors as unprofessional, and a majority had either observed or participated in each behavior. For all 46 behaviors, a greater percentage of women rated the behaviors as unprofessional. Men were more likely than women to have participated in behaviors. There were several significant differences in both the perceptions of specified behaviors and in self-reported observation of and/or involvement in those behaviors between institutions.Respondents indicated the most important professionalism issues relevant to medical practice include: respect for colleagues/patients, relationships with pharmaceutical companies, balancing home/work life, and admitting mistakes. They reported that professionalism can best be assessed by peers, patients, observation of non-medical work and timeliness/detail of paperwork. CONCLUSION: Defining professionalism in measurable terms is a challenge yet critical in order for it to be taught and assessed. Recognition of the differences by gender and institution should allow for tailored teaching and assessment of professionalism so that it is most meaningful. A shared understanding of what constitutes professional behavior is an important first step.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Life scripts are culturally shared expectations about the order and timing of life events in a prototypical life course. American and Danish undergraduates produced life story events and life scripts by listing the seven most important events in their own lives and in the lives of hypothetical people living ordinary lives. They also rated their events on several scales and completed measures of depression, PTSD symptoms, and centrality of a negative event to their lives. The Danish life script replicated earlier work; the American life script showed minor differences from the Danish life script, apparently reflecting genuine differences in shared events as well as less homogeneity in the American sample. Both consisted of mostly positive events that came disproportionately from ages 15 to 30. Valence of life story events correlated with life script valence, depression, PTSD symptoms, and identity. In the Danish undergraduates, measures of life story deviation from the life script correlated with measures of depression and PTSD symptoms.