3 resultados para electronic medical record

em Duke University


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This dissertation explores the complex process of organizational change, applying a behavioral lens to understand change in processes, products, and search behaviors. Chapter 1 examines new practice adoption, exploring factors that predict the extent to which routines are adopted “as designed” within the organization. Using medical record data obtained from the hospital’s Electronic Health Record (EHR) system I develop a novel measure of the “gap” between routine “as designed” and routine “as realized.” I link this to a survey administered to the hospital’s professional staff following the adoption of a new EHR system and find that beliefs about the expected impact of the change shape fidelity of the adopted practice to its design. This relationship is more pronounced in care units with experienced professionals and less pronounced when the care unit includes departmental leadership. This research offers new insights into the determinants of routine change in organizations, in particular suggesting the beliefs held by rank-and-file members of an organization are critical in new routine adoption. Chapter 2 explores changes to products, specifically examining culling behaviors in the mobile device industry. Using a panel of quarterly mobile device sales in Germany from 2004-2009, this chapter suggests that the organization’s response to performance feedback is conditional upon the degree to which decisions are centralized. While much of the research on product exit has pointed to economic drivers or prior experience, these central finding of this chapter—that performance below aspirations decreases the rate of phase-out—suggests that firms seek local solutions when doing poorly, which is consistent with behavioral explanations of organizational action. Chapter 3 uses a novel text analysis approach to examine how the allocation of attention within organizational subunits shapes adaptation in the form of search behaviors in Motorola from 1974-1997. It develops a theory that links organizational attention to search, and the results suggest a trade-off between both attentional specialization and coupling on search scope and depth. Specifically, specialized unit attention to a more narrow set of problems increases search scope but reduces search depth; increased attentional coupling also increases search scope at the cost of depth. This novel approach and these findings help clarify extant research on the behavioral outcomes of attention allocation, which have offered mixed results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient’s medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods.

The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data.

The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult.

First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion factors were derived for each scanner individually, but also were derived with the combined data from the two scanners as a means to investigate the feasibility of a scanner-independent method. Using the scanner-independent method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter, most of the fitted lens dose values fell within 10-15% of the measured values from the phantom study, suggesting that this is a fairly accurate method of estimating lens dose from the CTDIvol with knowledge of the patient’s head size.

Second, the dose reduction potential of organ-based tube current modulation (OB-TCM) and its effect on the CTDIvol-to-lens dose estimation method was investigated. The lens dose was measured with MOSFET dosimeters placed within the same six anthropomorphic phantoms. The phantoms were scanned with the five clinical head CT protocols with OB-TCM enabled on the one scanner model at our institution equipped with this software. The average decrease in lens dose with OB-TCM ranged from 13.5 to 26.0%. Using the size-specific method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter for protocols with OB-TCM, the majority of the fitted lens dose values fell within 15-18% of the measured values from the phantom study.

Third, the effect of gantry angulation on lens dose was investigated by measuring the lens dose with TLDs placed within the six anthropomorphic phantoms. The 2-dimensional spatial distribution of dose within the areas of the phantoms containing the orbit was measured with radiochromic film. A method was derived to determine the CTDIvol-to-lens dose conversion factor based upon distance from the primary beam scan range to the lens. The average dose to the lens region decreased substantially for almost all the phantoms (ranging from 67 to 92%) when the orbit was exposed to scattered radiation compared to the primary beam. The effectiveness of this method to reduce lens dose is highly dependent upon the shape and size of the head, which influences whether or not the angled scan range coverage can include the entire brain volume and still avoid the orbit.

The clinical component of this dissertation involved performing retrospective patient studies in the pediatric and adult populations, and reconstructing the lens doses from head CT examinations with the methods derived in the physics component. The cumulative lens doses in the patients selected for the retrospective study ranged from 40 to 1020 mGy in the pediatric group, and 53 to 2900 mGy in the adult group.

This dissertation represents a comprehensive approach to lens of the eye dosimetry in CT imaging of the head. The collected data and derived formulas can be used in future studies on radiation-induced cataracts from repeated CT imaging of the head. Additionally, it can be used in the areas of personalized patient dose management, and protocol optimization and clinician training.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Preclinical studies have found differential effects of isoflurane and propofol on the Alzheimer's disease (AD)-associated markers tau, phosphorylated tau (p-tau) and amyloid-β (Aβ). OBJECTIVE: We asked whether isoflurane and propofol have differential effects on the tau/Aβ ratio (the primary outcome), and individual AD biomarkers. We also examined whether genetic/intraoperative factors influenced perioperative changes in AD biomarkers. METHODS: Patients undergoing neurosurgical/otolaryngology procedures requiring lumbar cerebrospinal fluid (CSF) drain placement were prospectively randomized to receive isoflurane (n = 21) or propofol (n = 18) for anesthetic maintenance. We measured perioperative CSF sample AD markers, performed genotyping assays, and examined intraoperative data from the electronic anesthesia record. A repeated measures ANOVA was used to examine changes in AD markers by anesthetic type over time. RESULTS: The CSF tau/Aβ ratio did not differ between isoflurane- versus propofol-treated patients (p = 1.000). CSF tau/Aβ ratio and tau levels increased 10 and 24 h after drain placement (p = 2.002×10-6 and p = 1.985×10-6, respectively), mean CSF p-tau levels decreased (p = 0.005), and Aβ levels did not change (p = 0.152). There was no interaction between anesthetic treatment and time for any of these biomarkers. None of the examined genetic polymorphisms, including ApoE4, were associated with tau increase (n = 9 polymorphisms, p > 0.05 for all associations). CONCLUSION: Neurosurgery/otolaryngology procedures are associated with an increase in the CSF tau/Aβ ratio, and this increase was not influenced by anesthetic type. The increased CSF tau/Aβ ratio was largely driven by increases in tau levels. Future work should determine the functional/prognostic significance of these perioperative CSF tau elevations.