2 resultados para effective factors

em Duke University


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years, most low and middle-income countries, have adopted different approaches to universal health coverage (UHC), to ensure equity and financial risk protection in accessing essential healthcare services. UHC-related policies and delivery strategies are largely based on existing healthcare systems, a result of gradual development (based on local factors and priorities). Most countries have emphasized on health financing, and human resources for health (HRH) reform policies, based on good practices of several healthcare plans to deliver UHC for their population.

Health financing and labor market frameworks were used, to understand health financing, HRH dynamics, and to analyze key health policies implemented over the past decade in Kenya’s effort to achieve UHC. Through the understanding, policy options are proposed to Kenya; analyzing, and generating lessons from health financing, and HRH reforms experiences in China. Data was collected using mixed methods approach, utilizing both quantitative (documents and literature review), and qualitative (in-depth interviews) data collection techniques.

The problems in Kenya are substantial: high levels of out-of-pocket health expenditure, slow progress in expanding health insurance among informal sector workers, inefficiencies in pulling of health are revenues, inadequate deployed HRH, maldistribution of HRH, and inadequate quality measures in training health worker. The government has identified the critical role of strengthening primary health care and the National Hospital Insurance Fund (NHIF) in Kenya’s move towards UHC. Strengthening primary health care requires; re-defining the role of hospitals, and health insurance schemes, and training, deploying and retaining primary care professionals according to the health needs of the population; concepts not emphasized in Kenya’s healthcare reforms or programs design. Kenya’s top leadership commitment is urgently needed for tougher reforms implementation, and important lessons from China’s extensive health reforms in the past decade are beneficial. Key lessons from China include health insurance expansion through rigorous research, monitoring, and evaluation, substantially increasing government health expenditure, innovative primary healthcare strengthening, designing, and implementing health policy reforms that are responsive to the population, and regional approaches to strengthening HRH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose

The objective of our study was to test a new approach to approximating organ dose by using the effective energy of the combined 80kV/140kV beam used in fast kV switch dual-energy (DE) computed tomography (CT). The two primary focuses of the study were to first validate experimentally the dose equivalency between MOSFET and ion chamber (as a gold standard) in a fast kV switch DE environment, and secondly to estimate effective dose (ED) of DECT scans using MOSFET detectors and an anthropomorphic phantom.

Materials and Methods

A GE Discovery 750 CT scanner was employed using a fast-kV switch abdomen/pelvis protocol alternating between 80 kV and 140 kV. The specific aims of our study were to (1) Characterize the effective energy of the dual energy environment; (2) Estimate the f-factor for soft tissue; (3) Calibrate the MOSFET detectors using a beam with effective energy equal to the combined DE environment; (4) Validate our calibration by using MOSFET detectors and ion chamber to measure dose at the center of a CTDI body phantom; (5) Measure ED for an abdomen/pelvis scan using an anthropomorphic phantom and applying ICRP 103 tissue weighting factors; and (6) Estimate ED using AAPM Dose Length Product (DLP) method. The effective energy of the combined beam was calculated by measuring dose with an ion chamber under varying thicknesses of aluminum to determine half-value layer (HVL).

Results

The effective energy of the combined dual-energy beams was found to be 42.8 kV. After calibration, tissue dose in the center of the CTDI body phantom was measured at 1.71 ± 0.01 cGy using an ion chamber, and 1.73±0.04 and 1.69±0.09 using two separate MOSFET detectors. This result showed a -0.93% and 1.40 % difference, respectively, between ion chamber and MOSFET. ED from the dual-energy scan was calculated as 16.49 ± 0.04 mSv by the MOSFET method and 14.62 mSv by the DLP method.