2 resultados para Segneri, Paolo, 1624-1694

em Duke University


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The majority of total ankle arthroplasty (TAA) systems use extramedullary alignment guides for tibial component placement. However, at least 1 system offers intramedullary referencing. In total knee arthroplasty, studies suggest that tibial component placement is more accurate with intramedullary referencing. The purpose of this study was to compare the accuracy of extramedullary referencing with intramedullary referencing for tibial component placement in total ankle arthroplasty. METHODS: The coronal and sagittal tibial component alignment was evaluated on the postoperative weight-bearing anteroposterior (AP) and lateral radiographs of 236 consecutive fixed-bearing TAAs. Radiographs were measured blindly by 2 investigators. The postoperative alignment of the prosthesis was compared with the surgeon's intended alignment in both planes. The accuracy of tibial component alignment was compared between the extramedullary and intramedullary referencing techniques using unpaired t tests. Interrater and intrarater reliabilities were assessed with intraclass correlation coefficients (ICCs). RESULTS: Eighty-three tibial components placed with an extramedullary referencing technique were compared with 153 implants placed with an intramedullary referencing technique. The accuracy of the extramedullary referencing was within a mean of 1.5 ± 1.4 degrees and 4.1 ± 2.9 degrees in the coronal and sagittal planes, respectively. The accuracy of intramedullary referencing was within a mean of 1.4 ± 1.1 degrees and 2.5 ± 1.8 degrees in the coronal and sagittal planes, respectively. There was a significant difference (P < .001) between the 2 techniques with respect to the sagittal plane alignment. Interrater ICCs for coronal and sagittal alignment were high (0.81 and 0.94, respectively). Intrarater ICCs for coronal and sagittal alignment were high for both investigators. CONCLUSIONS: Initial sagittal plane tibial component alignment was notably more accurate when intramedullary referencing was used. Further studies are needed to determine the effect of this difference on clinical outcomes and long-term survivability of the implants. LEVEL OF EVIDENCE: Level III, retrospective comparative study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This volume originated in HASTAC’s first international conference, “Electronic Techtonics: Thinking at the Interface,” held at Duke University during April 19-21, 2007. “Electronic Techtonics” was the site of truly unforgettable conversations and encounters that traversed domains, disciplines, and media – conversations that explored the fluidity of technology both as interface as well as at the interface. This hardcopy version of the conference proceedings is published in conjunction with its electronic counterpart (found at www.hastac.org). Both versions exist as records of the range and depth of conversations that took place at the conference. Some of the papers in this volume are almost exact records of talks given at the conference, while others are versions that were revised and reworked some time after the conference. These papers are drawn from a variety of fields and we have not made an effort to homogenize them in any way, but have instead retained the individual format and style of each author.