7 resultados para Retinal Topography

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Segmentation of anatomical and pathological structures in ophthalmic images is crucial for the diagnosis and study of ocular diseases. However, manual segmentation is often a time-consuming and subjective process. This paper presents an automatic approach for segmenting retinal layers in Spectral Domain Optical Coherence Tomography images using graph theory and dynamic programming. Results show that this method accurately segments eight retinal layer boundaries in normal adult eyes more closely to an expert grader as compared to a second expert grader.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paleoprimatologists depend on relationships between form and function of teeth to reconstruct the diets of fossil species. Most of this work has been limited to studies of unworn teeth. A new approach, dental topographic analysis, allows the characterization and comparison of worn primate teeth. Variably worn museum specimens have been used to construct species-specific wear sequences so that measurements can be compared by wear stage among taxa with known differences in diet. This assumes that individuals in a species tend to wear their molar teeth in similar ways, a supposition that has yet to be tested. Here we evaluate this assumption with a longitudinal study of changes in tooth form over time in primates. Fourteen individual mantled howling monkeys (Alouatta palliata) were captured and then recaptured after 2, 4, and 7 years when possible at Hacienda La Pacifica in Costa Rica between 1989-1999. Dental impressions were taken each time, and molar casts were produced and analyzed using dental topographic analysis. Results showed consistent decreases in crown slope and occlusal relief. In contrast, crown angularity, a measure of surface jaggedness, remained fairly constant except with extreme wear. There were no evident differences between specimens collected in different microhabitats. These results suggest that different individual mantled howling monkeys wear their teeth down in similar ways, evidently following a species-specific wear sequence. Dental topographic analysis may therefore be used to compare morphology among similarly worn individuals from different species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dorsomedial prefrontal cortex (DMPFC) plays a central role in aspects of cognitive control and decision making. Here, we provide evidence for an anterior-to-posterior topography within the DMPFC using tasks that evoke three distinct forms of control demands--response, decision, and strategic--each of which could be mapped onto independent behavioral data. Specifically, we identify three spatially distinct regions within the DMPFC: a posterior region associated with control demands evoked by multiple incompatible responses, a middle region associated with control demands evoked by the relative desirability of decision options, and an anterior region that predicts control demands related to deviations from an individual's preferred decision-making strategy. These results provide new insight into the functional organization of DMPFC and suggest how recent controversies about its role in complex decision making and response mapping can be reconciled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The beta-adrenergic receptor kinase is an enzyme, possibly analogous to rhodopsin kinase, that multiply phosphorylates the beta-adrenergic receptor only when it is occupied by stimulatory agonists. Since this kinase may play an important role in mediating the process of homologous, or agonist-specific, desensitization, we investigated the functional consequences of receptor phosphorylation by the kinase and possible analogies with the mechanism of action of rhodopsin kinase. Pure hamster lung beta 2-adrenergic receptor, reconstituted in phospholipid vesicles, was assessed for its ability to mediate agonist-promoted stimulation of the GTPase activity of coreconstituted stimulatory guanine nucleotide-binding regulatory protein. When the receptor was phosphorylated by partially (approximately 350-fold) purified preparations of beta-adrenergic receptor kinase, as much as 80% inactivation of its functional activity was observed. However, the use of more highly purified enzyme preparations led to a dramatic decrease in the ability of phosphorylation to inactivate the receptor such that pure enzyme preparations (approximately 20,000-fold purified) caused only minimal (approximately 1off/- 7%) inactivation. Addition of pure retinal arrestin (48-kDa protein or S antigen), which is involved in enhancing the inactivating effect of rhodopsin phosphorylation by rhodopsin kinase, led to partial restoration of the functional effect of beta-adrenergic receptor kinase-promoted phosphorylation (41 +/- 3% inactivation). These results suggest the possibility that a protein analogous to retinal arrestin may exist in other tissues and function in concert with beta-adrenergic receptor kinase to regulate the activity of adenylate cyclase-coupled receptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advancements in retinal imaging technologies have drastically improved the quality of eye care in the past couple decades. Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) are two examples of critical imaging modalities for the diagnosis of retinal pathologies. However current-generation SLO and OCT systems have limitations in diagnostic capability due to the following factors: the use of bulky tabletop systems, monochromatic imaging, and resolution degradation due to ocular aberrations and diffraction.

Bulky tabletop SLO and OCT systems are incapable of imaging patients that are supine, under anesthesia, or otherwise unable to maintain the required posture and fixation. Monochromatic SLO and OCT imaging prevents the identification of various color-specific diagnostic markers visible with color fundus photography like those of neovascular age-related macular degeneration. Resolution degradation due to ocular aberrations and diffraction has prevented the imaging of photoreceptors close to the fovea without the use of adaptive optics (AO), which require bulky and expensive components that limit the potential for widespread clinical use.

In this dissertation, techniques for extending the diagnostic capability of SLO and OCT systems are developed. These techniques include design strategies for miniaturizing and combining SLO and OCT to permit multi-modal, lightweight handheld probes to extend high quality retinal imaging to pediatric eye care. In addition, a method for extending true color retinal imaging to SLO to enable high-contrast, depth-resolved, high-fidelity color fundus imaging is demonstrated using a supercontinuum light source. Finally, the development and combination of SLO with a super-resolution confocal microscopy technique known as optical photon reassignment (OPRA) is demonstrated to enable high-resolution imaging of retinal photoreceptors without the use of adaptive optics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Three dental topography measurements: Dirichlet Normal Energy (DNE), Relief Index (RFI), and Orientation Patch Count Rotated (OPCR) are examined for their interaction with measures of wear, within and between upper and lower molars in Alouatta palliata. Potential inferences of the "dental sculpting" phenomenon are explored. MATERIALS AND METHODS: Fifteen occluding pairs of howling monkey first molars (15 upper, 15 lower) opportunistically collected from La Pacifica, Costa Rica, were selected to sample wear stages ranging from unworn to heavily worn as measured by the Dentine Exposure Ratio (DER). DNE, RFI, and OPCR were measured from three-dimensional surface reconstructions (PLY files) derived from high-resolution CT scans. Relationships among the variables were tested with regression analyses. RESULTS: Upper molars have more cutting edges, exhibiting significantly higher DNE, but have significantly lower RFI values. However, the relationships among the measures are concordant across both sets of molars. DER and EDJL are curvilinearly related. DER is positively correlated with DNE, negatively correlated with RFI, and uncorrelated with OPCR. EDJL is not correlated with DNE, or RFI, but is positively correlated with OPCR among lower molars only. DISCUSSION: The relationships among these metrics suggest that howling monkey teeth adaptively engage macrowear. DNE increases with wear in this sample presumably improving food breakdown. RFI is initially high but declines with wear, suggesting that the initially high RFI safeguards against dental senescence. OPCR values in howling monkey teeth do not show a clear relationship with wear changes.