6 resultados para Quantities and measurements

em Duke University


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Six species of prosimians inhabiting the montane rain forest of the Ranomafana National Park located in southeastern Madagascar were captured, weighed, and measured during the months of May or June of 1987, 1988, and 1989. There were no significant differences in body weights and measurements between male and femaleEulemur rubriventer (red-bellied lemur) orEulemur fulvus rufus (red-fronted lemur). Adult femalePropithecus diadema edwardsi (Milne Edward's sifaka) were heavier than males but the difference was not significant. A fewAvahi laniger laniger (woolly lemur),Hapalemur aureus (golden bamboo lemur) andH. g. griseus (gentle bamboo lemur) also were captured and measured. Body weights of the same individual adultP. d. edwardsi changed over the three years, suggesting variation in food availability. Although there was no difference in body weight among adult males of two groups ofP. d. edwardsi, one male in each group had a testicular volume four times larger than that of other males, even though these measurements were taken five months after the breeding season. These data suggest that only one adult male mates in each group. Testicular size of the polygynousE. f. rufus males was significantly larger than that of the monogamousE. rubriventer. © 1992 Academic Press Limited.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

X-ray mammography has been the gold standard for breast imaging for decades, despite the significant limitations posed by the two dimensional (2D) image acquisitions. Difficulty in diagnosing lesions close to the chest wall and axilla, high amount of structural overlap and patient discomfort due to compression are only some of these limitations. To overcome these drawbacks, three dimensional (3D) breast imaging modalities have been developed including dual modality single photon emission computed tomography (SPECT) and computed tomography (CT) systems. This thesis focuses on the development and integration of the next generation of such a device for dedicated breast imaging. The goals of this dissertation work are to: [1] understand and characterize any effects of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without interference from the other. Such a system would overcome artifacts resulting from incompletely sampled divergent cone beam imaging schemes and allow imaging closer to the chest wall, which other systems currently under research and development elsewhere cannot achieve.

The dependence of x-ray scatter radiation on object shape, size, material composition and the CT acquisition trajectory, was investigated with a well-established beam stop array (BSA) scatter correction method. While the 2D scatter to primary ratio (SPR) was the main metric used to characterize total system scatter, a new metric called ‘normalized scatter contribution’ was developed to compare the results of scatter correction on 3D reconstructed volumes. Scatter estimation studies were undertaken with a sinusoidal saddle (±15° polar tilt) orbit and a traditional circular (AZOR) orbit. Clinical studies to acquire data for scatter correction were used to evaluate the 2D SPR on a small set of patients scanned with the AZOR orbit. Clinical SPR results showed clear dependence of scatter on breast composition and glandular tissue distribution, otherwise consistent with the overall phantom-based size and density measurements. Additionally, SPR dependence was also observed on the acquisition trajectory where 2D scatter increased with an increase in the polar tilt angle of the system.

The dose delivered by any imaging system is of primary importance from the patient’s point of view, and therefore trajectory related differences in the dose distribution in a target volume were evaluated. Monte Carlo simulations as well as physical measurements using radiochromic film were undertaken using saddle and AZOR orbits. Results illustrated that both orbits deliver comparable dose to the target volume, and only slightly differ in distribution within the volume. Simulations and measurements showed similar results, and all measured dose values were within the standard screening mammography-specific, 6 mGy dose limit, which is used as a benchmark for dose comparisons.

Hounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is very important, especially when using non-traditional trajectories. Uniform phantoms filled with various uniform density fluids were used to investigate differences in HU accuracy between saddle and AZOR orbits. Results illustrate the considerably better performance of the saddle orbit, especially close to the chest and nipple region of what would clinically be a pedant breast volume. The AZOR orbit causes shading artifacts near the nipple, due to insufficient sampling, rendering a major portion of the scanned phantom unusable, whereas the saddle orbit performs exceptionally well and provides a tighter distribution of HU values in reconstructed volumes.

Finally, the third generation, fully-suspended SPECT-CT system was designed in and developed in our lab. A novel mechanical method using a linear motor was developed for tilting the CT system. A new x-ray source and a custom made 40 x 30 cm2 detector were integrated on to this system. The SPECT system was nested, in the center of the gantry, orthogonal to the CT source-detector pair. The SPECT system tilts on a goniometer, and the newly developed CT tilting mechanism allows ±15° maximum polar tilting of the CT system. The entire gantry is mounted on a rotation stage, allowing complex arbitrary trajectories for each system, without interference from the other, while having a common field of view. This hybrid system shows potential to be used clinically as a diagnostic tool for dedicated breast imaging.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper discusses results from a study of the use of cleaner cooking solutions and general health status of people in rural areas from the Battambang province of Cambodia. Data collection included 372 demographic, health and socio-economic surveys with households living in 6 villages in the Samlout district, general health examinations, and measurements of stove use and household concentrations of PM 2.5. The data reveal that health in this population is a major concern, with a very high prevalence of reported abdominal pain, nausea, chronic cough, chest pains, and fever during examinations.  At the household level, we find that clean stove ownership is significantly correlated with the educational status of household head and socio-economic status of a household. Respondents from households with clean stoves appear less likely (though not statistically significantly so) to report household individuals having health problems such as occasional cough, high blood pressure and tuberculosis. Concentrations of PM2.5 are positively correlated with prevalence of occasional cough, high blood pressure and tuberculosis. Based on these results, we advise field testing and evaluation of targeted health interventions in these villages to address the numerous concerns of the local population, including exploring the potential role of clean stoves.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The strongly enhanced and localized optical fields that occur within the gaps between metallic nanostructures can be leveraged for a wide range of functionality in nanophotonic and optical metamaterial applications. Here, we introduce a means of precise control over these nanoscale gaps through the application of a molecular spacer layer that is self-assembled onto a gold film, upon which gold nanoparticles (NPs) are deposited electrostatically. Simulations using a three-dimensional finite element model and measurements from single NPs confirm that the gaps formed by this process, between the NP and the gold film, are highly reproducible transducers of surface-enhanced resonant Raman scattering. With a spacer layer of roughly 1.6 nm, all NPs exhibit a strong Raman signal that decays rapidly as the spacer layer is increased.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We consider a deterministic system with two conserved quantities and infinity many invariant measures. However the systems possess a unique invariant measure when enough stochastic forcing and balancing dissipation are added. We then show that as the forcing and dissipation are removed a unique limit of the deterministic system is selected. The exact structure of the limiting measure depends on the specifics of the stochastic forcing.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Based on thermodynamic principles, we derive expressions quantifying the non-harmonic vibrational behavior of materials, which are rigorous yet easily evaluated from experimentally available data for the thermal expansion coefficient and the phonon density of states. These experimentally- derived quantities are valuable to benchmark first-principles theoretical predictions of harmonic and non-harmonic thermal behaviors using perturbation theory, ab initio molecular-dynamics, or Monte-Carlo simulations. We illustrate this analysis by computing the harmonic, dilational, and anharmonic contributions to the entropy, internal energy, and free energy of elemental aluminum and the ordered compound FeSi over a wide range of temperature. Results agree well with previous data in the literature and provide an efficient approach to estimate anharmonic effects in materials.