Resumo:
Knowledge-based radiation treatment is an emerging concept in radiotherapy. It
mainly refers to the technique that can guide or automate treatment planning in
clinic by learning from prior knowledge. Dierent models are developed to realize
it, one of which is proposed by Yuan et al. at Duke for lung IMRT planning. This
model can automatically determine both beam conguration and optimization ob-
jectives with non-coplanar beams based on patient-specic anatomical information.
Although plans automatically generated by this model demonstrate equivalent or
better dosimetric quality compared to clinical approved plans, its validity and gener-
ality are limited due to the empirical assignment to a coecient called angle spread
constraint dened in the beam eciency index used for beam ranking. To eliminate
these limitations, a systematic study on this coecient is needed to acquire evidences
for its optimal value.
To achieve this purpose, eleven lung cancer patients with complex tumor shape
with non-coplanar beams adopted in clinical approved plans were retrospectively
studied in the frame of the automatic lung IMRT treatment algorithm. The primary
and boost plans used in three patients were treated as dierent cases due to the
dierent target size and shape. A total of 14 lung cases, thus, were re-planned using
the knowledge-based automatic lung IMRT planning algorithm by varying angle
spread constraint from 0 to 1 with increment of 0.2. A modied beam angle eciency
index used for navigate the beam selection was adopted. Great eorts were made to assure the quality of plans associated to every angle spread constraint as good
as possible. Important dosimetric parameters for PTV and OARs, quantitatively
re
ecting the plan quality, were extracted from the DVHs and analyzed as a function
of angle spread constraint for each case. Comparisons of these parameters between
clinical plans and model-based plans were evaluated by two-sampled Students t-tests,
and regression analysis on a composite index built on the percentage errors between
dosimetric parameters in the model-based plans and those in the clinical plans as a
function of angle spread constraint was performed.
Results show that model-based plans generally have equivalent or better quality
than clinical approved plans, qualitatively and quantitatively. All dosimetric param-
eters except those for lungs in the automatically generated plans are statistically
better or comparable to those in the clinical plans. On average, more than 15% re-
duction on conformity index and homogeneity index for PTV and V40, V60 for heart
while an 8% and 3% increase on V5, V20 for lungs, respectively, are observed. The
intra-plan comparison among model-based plans demonstrates that plan quality does
not change much with angle spread constraint larger than 0.4. Further examination
on the variation curve of the composite index as a function of angle spread constraint
shows that 0.6 is the optimal value that can result in statistically the best achievable
plans.
Resumo:
Brain-computer interfaces (BCI) have the potential to restore communication or control abilities in individuals with severe neuromuscular limitations, such as those with amyotrophic lateral sclerosis (ALS). The role of a BCI is to extract and decode relevant information that conveys a user's intent directly from brain electro-physiological signals and translate this information into executable commands to control external devices. However, the BCI decision-making process is error-prone due to noisy electro-physiological data, representing the classic problem of efficiently transmitting and receiving information via a noisy communication channel.
This research focuses on P300-based BCIs which rely predominantly on event-related potentials (ERP) that are elicited as a function of a user's uncertainty regarding stimulus events, in either an acoustic or a visual oddball recognition task. The P300-based BCI system enables users to communicate messages from a set of choices by selecting a target character or icon that conveys a desired intent or action. P300-based BCIs have been widely researched as a communication alternative, especially in individuals with ALS who represent a target BCI user population. For the P300-based BCI, repeated data measurements are required to enhance the low signal-to-noise ratio of the elicited ERPs embedded in electroencephalography (EEG) data, in order to improve the accuracy of the target character estimation process. As a result, BCIs have relatively slower speeds when compared to other commercial assistive communication devices, and this limits BCI adoption by their target user population. The goal of this research is to develop algorithms that take into account the physical limitations of the target BCI population to improve the efficiency of ERP-based spellers for real-world communication.
In this work, it is hypothesised that building adaptive capabilities into the BCI framework can potentially give the BCI system the flexibility to improve performance by adjusting system parameters in response to changing user inputs. The research in this work addresses three potential areas for improvement within the P300 speller framework: information optimisation, target character estimation and error correction. The visual interface and its operation control the method by which the ERPs are elicited through the presentation of stimulus events. The parameters of the stimulus presentation paradigm can be modified to modulate and enhance the elicited ERPs. A new stimulus presentation paradigm is developed in order to maximise the information content that is presented to the user by tuning stimulus paradigm parameters to positively affect performance. Internally, the BCI system determines the amount of data to collect and the method by which these data are processed to estimate the user's target character. Algorithms that exploit language information are developed to enhance the target character estimation process and to correct erroneous BCI selections. In addition, a new model-based method to predict BCI performance is developed, an approach which is independent of stimulus presentation paradigm and accounts for dynamic data collection. The studies presented in this work provide evidence that the proposed methods for incorporating adaptive strategies in the three areas have the potential to significantly improve BCI communication rates, and the proposed method for predicting BCI performance provides a reliable means to pre-assess BCI performance without extensive online testing.