9 resultados para Mark-up pricing

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent empirical findings suggest that the long-run dependence in U.S. stock market volatility is best described by a slowly mean-reverting fractionally integrated process. The present study complements this existing time-series-based evidence by comparing the risk-neutralized option pricing distributions from various ARCH-type formulations. Utilizing a panel data set consisting of newly created exchange traded long-term equity anticipation securities, or leaps, on the Standard and Poor's 500 stock market index with maturity times ranging up to three years, we find that the degree of mean reversion in the volatility process implicit in these prices is best described by a Fractionally Integrated EGARCH (FIEGARCH) model. © 1999 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the robustness of the estimate of a positive productivity shock on hours to the presence of a possible unit root in hours. Estimations in levels or in first differences provide opposite conclusions. We rely on an agnostic procedure in which the researcher does not have to choose between a specification in levels or in first differences. We find that a positive productivity shock has a negative impact effect on hours, but the effect is much shorter lived, and disappears after two quarters. The effect becomes positive at business-cycle frequencies, although it is not significant. © 2005 Cambridge University Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following the completion of a 20-week, open-label study of the safety and efficacy of liquid rivastigmine for adolescents with Down syndrome, 5 of the 10 adolescents in the clinical trial continued long-term rivastigmine therapy and 5 did not. After an average period of 38 months, all 10 subjects returned for a follow-up assessment to determine the safety and efficacy of long-term rivastigmine use. Rivastigmine was well tolerated and overall health appeared to be unaffected by long-term rivastigmine use. Performance change on cognitive and language measures administered at the termination of the open-label clinical trial was compared between the two groups. No between-group difference in median performance change across the long-term period was found, suggesting that the long-term use of rivastigmine does not improve cognitive and language performance. However, two subjects demonstrated remarkable improvement in adaptive function over the long-term period. Both subjects had received long-term rivastigmine therapy. The discussion addresses the challenge of assessing cognitive change in clinical trials using adolescents with Down syndrome as subjects and the use of group versus individual data to evaluate the relevance of medication effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the applicability of the present-value asset pricing model to fishing quota markets by applying instrumental variable panel data estimation techniques to 15 years of market transactions from New Zealand's individual transferable quota (ITQ) market. In addition to the influence of current fishing rents, we explore the effect of market interest rates, risk, and expected changes in future rents on quota asset prices. The results indicate that quota asset prices are positively related to declines in interest rates, lower levels of risk, expected increases in future fish prices, and expected cost reductions from rationalization under the quota system. © 2007 American Agricultural Economics Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In Tanzania, HIV-1 RNA testing is rarely available and not standard of care. Determining virologic failure is challenging and resistance mutations accumulate, thereby compromising second-line therapy. We evaluated durability of antiretroviral therapy (ART) and predictors of virologic failure among a pediatric cohort at four-year follow-up. METHODS: This was a prospective cross-sectional study with retrospective chart review evaluating a perinatally HIV-infected Tanzanian cohort enrolled in 2008-09 with repeat HIV-1 RNA in 2012-13. Demographic, clinical, and laboratory data were extracted from charts, resistance mutations from 2008-9 were analyzed, and prospective HIV RNA was obtained. RESULTS: 161 (78%) participants of the original cohort consented to repeat HIV RNA. The average age was 12.2 years (55% adolescents ≥12 years). Average time on ART was 6.4 years with 41% receiving second-line (protease inhibitor based) therapy. Among those originally suppressed on a first-line (non-nucleoside reverse transcriptase based regimen) 76% remained suppressed. Of those originally failing first-line, 88% were switched to second-line and 72% have suppressed virus. Increased level of viremia and duration of ART trended with an increased number of thymidine analogue mutations (TAMs). Increased TAMs increased the odds of virologic failure (p = 0.18), as did adolescent age (p < 0.01). CONCLUSIONS: After viral load testing in 2008-09 many participants switched to second-line therapy. The majority achieved virologic suppression despite multiple resistance mutations. Though virologic testing would likely hasten the switch to second-line among those failing, methods to improve adherence is critical to maximize durability of ART and improve virologic outcomes among youth in resource-limited settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Notch signaling is implicated in prostate cancer progression and docetaxel resistance. Cui and colleagues describe the additive efficacy and mechanisms of a γ-secretase inhibitor, PF-03084014, and docetaxel in preclinical models of prostate cancer, suggesting the need for further clinical development of Notch pathway modulators in men with metastatic prostate cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.

In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.

Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.

For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.

For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.

Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.