Resumo:

Herein, we demonstrate that highly sensitive conductometric gas nanosensors for H(2)S can be synthesized by electrodepositing gold nanoparticles on single-walled carbon nanotube (SWNT) networks. Adjusting the electrodeposition conditions allowed for tuning of the size and number of gold nanoparticles deposited. The best H(2)S sensing performance was obtained with discrete gold nanodeposits rather than continuous nanowires. The gas nanosensors could sense H(2)S in air at room temperature with a 3 ppb limit of detection. The sensors were reversible, and increasing the bias voltage reduced the sensor recovery time, probably by local Joule heating. The sensing mechanism is believed to be based on the modulation of the conduction path across the nanotubes emanating from the modulation of electron exchange between the gold and carbon nanotube defect sites when exposed to H(2)S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Luminescent semiconductor nanocrystals, also known as quantum dots (QDs), have advanced the fields of molecular diagnostics and nanotherapeutics. Much of the initial progress for QDs in biology and medicine has focused on developing new biosensing formats to push the limit of detection sensitivity. Nevertheless, QDs can be more than passive bio-probes or labels for biological imaging and cellular studies. The high surface-to-volume ratio of QDs enables the construction of a "smart" multifunctional nanoplatform, where the QDs serve not only as an imaging agent but also a nanoscaffold catering for therapeutic and diagnostic (theranostic) modalities. This mini review highlights the emerging applications of functionalized QDs as fluorescence contrast agents for imaging or as nanoscale vehicles for delivery of therapeutics, with special attention paid to the promise and challenges towards QD-based theranostics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: It is unclear whether diagnostic protocols based on cardiac markers to identify low-risk chest pain patients suitable for early release from the emergency department can be applied to patients older than 65 years or with traditional cardiac risk factors. METHODS AND RESULTS: In a single-center retrospective study of 231 consecutive patients with high-risk factor burden in which a first cardiac troponin (cTn) level was measured in the emergency department and a second cTn sample was drawn 4 to 14 hours later, we compared the performance of a modified 2-Hour Accelerated Diagnostic Protocol to Assess Patients with Chest Pain Using Contemporary Troponins as the Only Biomarker (ADAPT) rule to a new risk classification scheme that identifies patients as low risk if they have no known coronary artery disease, a nonischemic electrocardiogram, and 2 cTn levels below the assay's limit of detection. Demographic and outcome data were abstracted through chart review. The median age of our population was 64 years, and 75% had Thrombosis In Myocardial Infarction risk score ≥2. Using our risk classification rule, 53 (23%) patients were low risk with a negative predictive value for 30-day cardiac events of 98%. Applying a modified ADAPT rule to our cohort, 18 (8%) patients were identified as low risk with a negative predictive value of 100%. In a sensitivity analysis, the negative predictive value of our risk algorithm did not change when we relied only on undetectable baseline cTn and eliminated the second cTn assessment. CONCLUSIONS: If confirmed in prospective studies, this less-restrictive risk classification strategy could be used to safely identify chest pain patients with more traditional cardiac risk factors for early emergency department release.