4 resultados para Instant messaging
em Duke University
Resumo:
Background: Evidence-based medication and lifestyle modification are important for secondary prevention of cardiovascular disease but are underutilized. Mobile health strategies could address this gap but existing evidence is mixed. Therefore, we piloted a pre-post study to assess the impact of patient-directed text messages as a means of improving medication adherence and modifying major health risk behaviors among coronary heart disease (CHD) patients in Hainan, China.
Methods: 92 CVD patients were surveyed between June and August 2015 (before the intervention) and then between October and December 2015 (after 12 week intervention) about (a) medication use (b) smoking status,(c) fruit and vegetable consumption, and (d) physical activity uptake. Acceptability of text-messaging intervention was assessed at follow-up. Descriptive statistics, along with paired comparisons between the pre and post outcomes were conducted using both parametric (t-test) and non-parametric (Wilcoxon signed rank test) methods.
Results: The number of respondents at follow-up was 82 (89% retention rate). Significant improvements were observed for medication adherence (P<0.001) and for the number of cigarettes smoked per day (P=.022). However there was no change in the number of smokers who quitted smoking at follow-up. There were insignificant changes for physical activity (P=0.91) and fruit and vegetable consumption.
Resumo:
BACKGROUND: Body image (BI) and body satisfaction may be important in understanding weight loss behaviors, particularly during the postpartum period. We assessed these constructs among African American and white overweight postpartum women. METHODS: The sample included 162 women (73 African American and 89 white) in the intervention arm 6 months into the Active Mothers Postpartum (AMP) Study, a nutritional and physical activity weight loss intervention. BIs, self-reported using the Stunkard figure rating scale, were compared assessing mean values by race. Body satisfaction was measured using body discrepancy (BD), calculated as perceived current image minus ideal image (BD<0: desire to be heavier; BD>0: desire to be lighter). BD was assessed by race for: BD(Ideal) (current image minus the ideal image) and BD(Ideal Mother) (current image minus ideal mother image). RESULTS: Compared with white women, African American women were younger and were less likely to report being married, having any college education, or residing in households with annual incomes >$30,000 (all p < 0.01). They also had a higher mean body mass index (BMI) (p = 0.04), although perceived current BI did not differ by race (p = 0.21). African Americans had higher mean ideal (p = 0.07) and ideal mother (p = 0.001) BIs compared with whites. African Americans' mean BDs (adjusting for age, BMI, education, income, marital status, and interaction terms) were significantly lower than those of whites, indicating greater body satisfaction among African Americans (BD(Ideal): 1.7 vs. 2.3, p = 0.005; BD(Ideal Mother): 1.1 vs. 1.8, p = 0.0002). CONCLUSIONS: Racial differences exist in postpartum weight, ideal images, and body satisfaction. Healthcare providers should consider tailored messaging that accounts for these racially different perceptions and factors when designing weight loss programs for overweight mothers.
Resumo:
BACKGROUND: Stroke is one of the most disabling and costly impairments of adulthood in the United States. Stroke patients clearly benefit from intensive inpatient care, but due to the high cost, there is considerable interest in implementing interventions to reduce hospital lengths of stay. Early discharge rehabilitation programs require coordinated, well-organized home-based rehabilitation, yet lack of sufficient information about the home setting impedes successful rehabilitation. This trial examines a multifaceted telerehabilitation (TR) intervention that uses telehealth technology to simultaneously evaluate the home environment, assess the patient's mobility skills, initiate rehabilitative treatment, prescribe exercises tailored for stroke patients and provide periodic goal oriented reassessment, feedback and encouragement. METHODS: We describe an ongoing Phase II, 2-arm, 3-site randomized controlled trial (RCT) that determines primarily the effect of TR on physical function and secondarily the effect on disability, falls-related self-efficacy, and patient satisfaction. Fifty participants with a diagnosis of ischemic or hemorrhagic stroke will be randomly assigned to one of two groups: (a) TR; or (b) Usual Care. The TR intervention uses a combination of three videotaped visits and five telephone calls, an in-home messaging device, and additional telephonic contact as needed over a 3-month study period, to provide a progressive rehabilitative intervention with a treatment goal of safe functional mobility of the individual within an accessible home environment. Dependent variables will be measured at baseline, 3-, and 6-months and analyzed with a linear mixed-effects model across all time points. DISCUSSION: For patients recovering from stroke, the use of TR to provide home assessments and follow-up training in prescribed equipment has the potential to effectively supplement existing home health services, assist transition to home and increase efficiency. This may be particularly relevant when patients live in remote locations, as is the case for many veterans. TRIAL REGISTRATION: Clinical Trials.gov Identifier: NCT00384748.
Resumo:
The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.
In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.
Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.
For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.
For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.
Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.