5 resultados para Input technologies
em Duke University
Resumo:
A set of 13 US based experts in post-combustion and oxy-fuel combustion CO2 capture systems responded to an extensive questionnaire asking their views on the present status and future expected performance and costs for amine-based, chilled ammonia, and oxy-combustion retrofits of coal-fired power plants. This paper presents the experts' responses for technology maturity, ideal plant characteristics for early adopters, and the extent to which R&D and deployment incentives will impact costs. It also presents the best estimates and 95% confidence limits of the energy penalties associated with amine-based systems. The results show a general consensus that amine-based systems are closer to commercial application, but potential for improving performance and lowering costs is limited; chilled ammonia and oxy-combustion offer greater potential for cost reductions, but not without greater uncertainty regarding scale and technical feasibility. © 2011 Elsevier Ltd.
Resumo:
Small bistratified cells (SBCs) in the primate retina carry a major blue-yellow opponent signal to the brain. We found that SBCs also carry signals from rod photoreceptors, with the same sign as S cone input. SBCs exhibited robust responses under low scotopic conditions. Physiological and anatomical experiments indicated that this rod input arose from the AII amacrine cell-mediated rod pathway. Rod and cone signals were both present in SBCs at mesopic light levels. These findings have three implications. First, more retinal circuits may multiplex rod and cone signals than were previously thought to, efficiently exploiting the limited number of optic nerve fibers. Second, signals from AII amacrine cells may diverge to most or all of the approximately 20 retinal ganglion cell types in the peripheral primate retina. Third, rod input to SBCs may be the substrate for behavioral biases toward perception of blue at mesopic light levels.
Resumo:
BACKGROUND: Measurement of CD4+ T-lymphocytes (CD4) is a crucial parameter in the management of HIV patients, particularly in determining eligibility to initiate antiretroviral treatment (ART). A number of technologies exist for CD4 enumeration, with considerable variation in cost, complexity, and operational requirements. We conducted a systematic review of the performance of technologies for CD4 enumeration. METHODS AND FINDINGS: Studies were identified by searching electronic databases MEDLINE and EMBASE using a pre-defined search strategy. Data on test accuracy and precision included bias and limits of agreement with a reference standard, and misclassification probabilities around CD4 thresholds of 200 and 350 cells/μl over a clinically relevant range. The secondary outcome measure was test imprecision, expressed as % coefficient of variation. Thirty-two studies evaluating 15 CD4 technologies were included, of which less than half presented data on bias and misclassification compared to the same reference technology. At CD4 counts <350 cells/μl, bias ranged from -35.2 to +13.1 cells/μl while at counts >350 cells/μl, bias ranged from -70.7 to +47 cells/μl, compared to the BD FACSCount as a reference technology. Misclassification around the threshold of 350 cells/μl ranged from 1-29% for upward classification, resulting in under-treatment, and 7-68% for downward classification resulting in overtreatment. Less than half of these studies reported within laboratory precision or reproducibility of the CD4 values obtained. CONCLUSIONS: A wide range of bias and percent misclassification around treatment thresholds were reported on the CD4 enumeration technologies included in this review, with few studies reporting assay precision. The lack of standardised methodology on test evaluation, including the use of different reference standards, is a barrier to assessing relative assay performance and could hinder the introduction of new point-of-care assays in countries where they are most needed.
Resumo:
Many neurons in the frontal eye field (FEF) exhibit visual responses and are thought to play important roles in visuosaccadic behavior. The FEF, however, is far removed from striate cortex. Where do the FEF's visual signals come from? Usually they are reasonably assumed to enter the FEF through afferents from extrastriate cortex. Here we show that, surprisingly, visual signals also enter the FEF through a subcortical route: a disynaptic, ascending pathway originating in the intermediate layers of the superior colliculus (SC). We recorded from identified neurons at all three stages of this pathway (n=30-40 in each sample): FEF recipient neurons, orthodromically activated from the SC; mediodorsal thalamus (MD) relay neurons, antidromically activated from FEF and orthodromically activated from SC; and SC source neurons, antidromically activated from MD. We studied the neurons while monkeys performed delayed saccade tasks designed to temporally resolve visual responses from presaccadic discharges. We found, first, that most neurons at every stage in the pathway had visual responses, presaccadic bursts, or both. Second, we found marked similarities between the SC source neurons and MD relay neurons: in both samples, about 15% of the neurons had only a visual response, 10% had only a presaccadic burst, and 75% had both. In contrast, FEF recipient neurons tended to be more visual in nature: 50% had only a visual response, none had only a presaccadic burst, and 50% had both a visual response and a presaccadic burst. This suggests that in addition to their subcortical inputs, these FEF neurons also receive other visual inputs, e.g. from extrastriate cortex. We conclude that visual activity in the FEF results not only from cortical afferents but also from subcortical inputs. Intriguingly, this implies that some of the visual signals in FEF are pre-processed by the SC.