7 resultados para Image. Satisfaction

em Duke University


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Body image (BI) and body satisfaction may be important in understanding weight loss behaviors, particularly during the postpartum period. We assessed these constructs among African American and white overweight postpartum women. METHODS: The sample included 162 women (73 African American and 89 white) in the intervention arm 6 months into the Active Mothers Postpartum (AMP) Study, a nutritional and physical activity weight loss intervention. BIs, self-reported using the Stunkard figure rating scale, were compared assessing mean values by race. Body satisfaction was measured using body discrepancy (BD), calculated as perceived current image minus ideal image (BD<0: desire to be heavier; BD>0: desire to be lighter). BD was assessed by race for: BD(Ideal) (current image minus the ideal image) and BD(Ideal Mother) (current image minus ideal mother image). RESULTS: Compared with white women, African American women were younger and were less likely to report being married, having any college education, or residing in households with annual incomes >$30,000 (all p < 0.01). They also had a higher mean body mass index (BMI) (p = 0.04), although perceived current BI did not differ by race (p = 0.21). African Americans had higher mean ideal (p = 0.07) and ideal mother (p = 0.001) BIs compared with whites. African Americans' mean BDs (adjusting for age, BMI, education, income, marital status, and interaction terms) were significantly lower than those of whites, indicating greater body satisfaction among African Americans (BD(Ideal): 1.7 vs. 2.3, p = 0.005; BD(Ideal Mother): 1.1 vs. 1.8, p = 0.0002). CONCLUSIONS: Racial differences exist in postpartum weight, ideal images, and body satisfaction. Healthcare providers should consider tailored messaging that accounts for these racially different perceptions and factors when designing weight loss programs for overweight mothers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to characterize the image quality of our dedicated, quasi-monochromatic spectrum, cone beam breast imaging system under scatter corrected and non-scatter corrected conditions for a variety of breast compositions. CT projections were acquired of a breast phantom containing two concentric sets of acrylic spheres that varied in size (1-8mm) based on their polar position. The breast phantom was filled with 3 different concentrations of methanol and water, simulating a range of breast densities (0.79-1.0g/cc); acrylic yarn was sometimes included to simulate connective tissue of a breast. For each phantom condition, 2D scatter was measured for all projection angles. Scatter-corrected and uncorrected projections were then reconstructed with an iterative ordered subsets convex algorithm. Reconstructed image quality was characterized using SNR and contrast analysis, and followed by a human observer detection task for the spheres in the different concentric rings. Results show that scatter correction effectively reduces the cupping artifact and improves image contrast and SNR. Results from the observer study indicate that there was no statistical difference in the number or sizes of lesions observed in the scatter versus non-scatter corrected images for all densities. Nonetheless, applying scatter correction for differing breast conditions improves overall image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

© 2015 IEEE.In virtual reality applications, there is an aim to provide real time graphics which run at high refresh rates. However, there are many situations in which this is not possible due to simulation or rendering issues. When running at low frame rates, several aspects of the user experience are affected. For example, each frame is displayed for an extended period of time, causing a high persistence image artifact. The effect of this artifact is that movement may lose continuity, and the image jumps from one frame to another. In this paper, we discuss our initial exploration of the effects of high persistence frames caused by low refresh rates and compare it to high frame rates and to a technique we developed to mitigate the effects of low frame rates. In this technique, the low frame rate simulation images are displayed with low persistence by blanking out the display during the extra time such image would be displayed. In order to isolate the visual effects, we constructed a simulator for low and high persistence displays that does not affect input latency. A controlled user study comparing the three conditions for the tasks of 3D selection and navigation was conducted. Results indicate that the low persistence display technique may not negatively impact user experience or performance as compared to the high persistence case. Directions for future work on the use of low persistence displays for low frame rate situations are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative assessment of surgical margins is critical to ensuring residual tumor does not remain in a patient. Previously, we developed a fluorescence structured illumination microscope (SIM) system with a single-shot field of view (FOV) of 2.1 × 1.6 mm (3.4 mm2) and sub-cellular resolution (4.4 μm). The goal of this study was to test the utility of this technology for the detection of residual disease in a genetically engineered mouse model of sarcoma. Primary soft tissue sarcomas were generated in the hindlimb and after the tumor was surgically removed, the relevant margin was stained with acridine orange (AO), a vital stain that brightly stains cell nuclei and fibrous tissues. The tissues were imaged with the SIM system with the primary goal of visualizing fluorescent features from tumor nuclei. Given the heterogeneity of the background tissue (presence of adipose tissue and muscle), an algorithm known as maximally stable extremal regions (MSER) was optimized and applied to the images to specifically segment nuclear features. A logistic regression model was used to classify a tissue site as positive or negative by calculating area fraction and shape of the segmented features that were present and the resulting receiver operator curve (ROC) was generated by varying the probability threshold. Based on the ROC curves, the model was able to classify tumor and normal tissue with 77% sensitivity and 81% specificity (Youden's index). For an unbiased measure of the model performance, it was applied to a separate validation dataset that resulted in 73% sensitivity and 80% specificity. When this approach was applied to representative whole margins, for a tumor probability threshold of 50%, only 1.2% of all regions from the negative margin exceeded this threshold, while over 14.8% of all regions from the positive margin exceeded this threshold.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Office-based percutaneous revision of a testicular prosthesis has never been reported. A patient received a testicular prosthesis but was dissatisfied with the firmness of the implant. In an office setting, the prosthesis was inflated with additional fluid via a percutaneous approach. Evaluated outcomes included patient satisfaction, prosthesis size, recovery time, and cost savings. The patient was satisfied, with no infection, leak, or complication after more than 1 year of follow-up, at significantly less cost than revision surgery. Percutaneous adjustment of testicular prosthesis fill-volume can be safe, inexpensive, and result in good patient satisfaction.