2 resultados para HIGH-DENSITY POLYETHYLENE
em Duke University
Resumo:
This work is an investigation into collimator designs for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact neutron imaging system that can be implemented in a hospital. The envisioned application is for a spectroscopic imaging technique called neutron stimulated emission computed tomography (NSECT).
Previous NSECT studies have been performed using a Van-de-Graaff accelerator at the Triangle Universities Nuclear Laboratory (TUNL) in Duke University. This facility has provided invaluable research into the development of NSECT. To transition the current imaging method into a clinically feasible system, there is a need for a high-intensity fast neutron source that can produce collimated beams. The DD neutron generator from Adelphi Technologies Inc. is being explored as a possible candidate to provide the uncollimated neutrons. This DD generator is a compact source that produces 2.5 MeV fast neutrons with intensities of 1012 n/s (4π). The neutron energy is sufficient to excite most isotopes of interest in the body with the exception of carbon and oxygen. However, a special collimator is needed to collimate the 4π neutron emission into a narrow beam. This work describes the development and evaluation of a series of collimator designs to collimate the DD generator for narrow beams suitable for NSECT imaging.
A neutron collimator made of high-density polyethylene (HDPE) and lead was modeled and simulated using the GEANT4 toolkit. The collimator was designed as a 52 x 52 x 52 cm3 HDPE block coupled with 1 cm lead shielding. Non-tapering (cylindrical) and tapering (conical) opening designs were modeled into the collimator to permit passage of neutrons. The shape, size, and geometry of the aperture were varied to assess the effects on the collimated neutron beam. Parameters varied were: inlet diameter (1-5 cm), outlet diameter (1-5 cm), aperture diameter (0.5-1.5 cm), and aperture placement (13-39 cm). For each combination of collimator parameters, the spatial and energy distributions of neutrons and gammas were tracked and analyzed to determine three performance parameters: neutron beam-width, primary neutron flux, and the output quality. To evaluate these parameters, the simulated neutron beams are then regenerated for a NSECT breast scan. Scan involved a realistic breast lesion implanted into an anthropomorphic female phantom.
This work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-collimated neutron beam that can be used for NSECT breast imaging. The aperture diameter showed a strong correlation to the beam-width, where the collimated neutron beam-width was about 10% larger than the physical aperture diameter. In addition, a collimator opening consisting of a tapering inlet and cylindrical outlet allowed greater neutron throughput when compared to a simple cylindrical opening. The tapering inlet design can allow additional neutron throughput when the neck is placed farther from the source. On the other hand, the tapering designs also decrease output quality (i.e. increase in stray neutrons outside the primary collimated beam). All collimators are cataloged in measures of beam-width, neutron flux, and output quality. For a particular NSECT application, an optimal choice should be based on the collimator specifications listed in this work.
Resumo:
© 2016, Serdi and Springer-Verlag France.Objectives: The association between cognitive function and cholesterol levels is poorly understood and inconsistent results exist among the elderly. The purpose of this study is to investigate the association of cholesterol level with cognitive performance among Chinese elderly. Design: A cross-sectional study was implemented in 2012 and data were analyzed using generalized additive models, linear regression models and logistic regression models. Setting: Community-based setting in eight longevity areas in China. Subjects: A total of 2000 elderly aged 65 years and over (mean 85.8±12.0 years) participated in this study. Measurements: Total cholesterol (TC), triglycerides (TG), low density lipoprotein cholesterol (LDL-C) and high density lipoprotein cholesterol (HDL-C) concentration were determined and cognitive impairment was defined as Mini-Mental State Examination (MMSE) score≤23. Results: There was a significant positive linear association between TC, TG, LDL-C, HDL-C and MMSE score in linear regression models. Each 1 mmol/L increase in TC, TG, LDL-C and HDL-C corresponded to a decreased risk of cognitive impairment in logistic regression models. Compared with the lowest tertile, the highest tertile of TC, LDL-C and HDL-C had a lower risk of cognitive impairment. The adjusted odds ratios and 95% CI were 0.73(0.62–0.84) for TC, 0.81(0.70–0.94) for LDL-C and 0.81(0.70–0.94) for HDL-C. There was no gender difference in the protective effects of high TC and LDL-C levels on cognitive impairment. However, for high HDL-C levels the effect was only observed in women. High TC, LDL-C and HDL-C levels were associated with lower risk of cognitive impairment in the oldest old (aged 80 and older), but not in the younger elderly (aged 65 to 79 years). Conclusions: These findings suggest that cholesterol levels within the high normal range are associated with better cognitive performance in Chinese elderly, specifically in the oldest old. With further validation, low cholesterol may serve a clinical indicator of risk for cognitive impairment in the elderly.