3 resultados para GUIDELINE

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Guidance for appropriate utilisation of transthoracic echocardiograms (TTEs) can be incorporated into ordering prompts, potentially affecting the number of requests. METHODS: We incorporated data from the 2011 Appropriate Use Criteria for Echocardiography, the 2010 National Institute for Clinical Excellence Guideline on Chronic Heart Failure, and American College of Cardiology Choosing Wisely list on TTE use for dyspnoea, oedema and valvular disease into electronic ordering systems at Durham Veterans Affairs Medical Center. Our primary outcome was TTE orders per month. Secondary outcomes included rates of outpatient TTE ordering per 100 visits and frequency of brain natriuretic peptide (BNP) ordering prior to TTE. Outcomes were measured for 20 months before and 12 months after the intervention. RESULTS: The number of TTEs ordered did not decrease (338±32 TTEs/month prior vs 320±33 afterwards, p=0.12). Rates of outpatient TTE ordering decreased minimally post intervention (2.28 per 100 primary care/cardiology visits prior vs 1.99 afterwards, p<0.01). Effects on TTE ordering and ordering rate significantly interacted with time from intervention (p<0.02 for both), as the small initial effects waned after 6 months. The percentage of TTE orders with preceding BNP increased (36.5% prior vs 42.2% after for inpatients, p=0.01; 10.8% prior vs 14.5% after for outpatients, p<0.01). CONCLUSIONS: Ordering prompts for TTEs initially minimally reduced the number of TTEs ordered and increased BNP measurement at a single institution, but the effect on TTEs ordered was likely insignificant from a utilisation standpoint and decayed over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic field inhomogeneity results in image artifacts including signal loss, image blurring and distortions, leading to decreased diagnostic accuracy. Conventional multi-coil (MC) shimming method employs both RF coils and shimming coils, whose mutual interference induces a tradeoff between RF signal-to-noise (SNR) ratio and shimming performance. To address this issue, RF coils were integrated with direct-current (DC) shim coils to shim field inhomogeneity while concurrently emitting and receiving RF signal without being blocked by the shim coils. The currents applied to the new coils, termed iPRES (integrated parallel reception, excitation and shimming), were optimized in the numerical simulation to improve the shimming performance. The objectives of this work is to offer a guideline for designing the optimal iPRES coil arrays to shim the abdomen.

In this thesis work, the main field () inhomogeneity was evaluated by root mean square error (RMSE). To investigate the shimming abilities of iPRES coil arrays, a set of the human abdomen MRI data was collected for the numerical simulations. Thereafter, different simplified iPRES(N) coil arrays were numerically modeled, including a 1-channel iPRES coil and 8-channel iPRES coil arrays. For 8-channel iPRES coil arrays, each RF coil was split into smaller DC loops in the x, y and z direction to provide extra shimming freedom. Additionally, the number of DC loops in a RF coil was increased from 1 to 5 to find the optimal divisions in z direction. Furthermore, switches were numerically implemented into iPRES coils to reduce the number of power supplies while still providing similar shimming performance with equivalent iPRES coil arrays.

The optimizations demonstrate that the shimming ability of an iPRES coil array increases with number of DC loops per RF coil. Furthermore, the z direction divisions tend to be more effective in reducing field inhomogeneity than the x and y divisions. Moreover, the shimming performance of an iPRES coil array gradually reach to a saturation level when the number of DC loops per RF coil is large enough. Finally, when switches were numerically implemented in the iPRES(4) coil array, the number of power supplies can be reduced from 32 to 8 while keeping the shimming performance similar to iPRES(3) and better than iPRES(1). This thesis work offers a guidance for the designs of iPRES coil arrays.