5 resultados para Etiology and Diagnostic of SLE
em Duke University
Resumo:
Background: Too little information is available on Sri Lanka’s current capacity to provide community genetic services—antenatal genetic services in particular—to understand whether building that capacity could further improve and reduce disparity in maternal and child health. This qualitative research project seeks to gather information on congenital disorders, routine antenatal care, and the current state of antenatal screening testing services within that routine antenatal to assess the feasibility of and the need for scaling up antenatal genetics services in Sri Lanka. Methods: Nineteen key informant (KI) interviews were conducted with stakeholders in antenatal care and genetic services. Seven focus group discussions were held with a total of 56 Public Health Midwives (PHMs), the health workers responsible for antenatal care at the field level. Transcripts for all interviews and FGDs were analyzed for key themes, and themes were categorized to address the specific aims of the project. Results: Antenatal genetic services play a minor role in antenatal care, with screening and diagnostic procedures available in the private sector and paid for out-of-pocket. KIs and PHMs expect that demand for antenatal genetic services will increase as patients’ purchasing power and knowledge grow but note that prohibitive abortion laws limit the ability of patients to act on test results. Genetic services compete for limited financial and human resources in the free public health system, and inadequate information on the prevalence of congenital disorders limits the ability to understand whether funding for services related to those disorders should be increased. A number of alternatives to scaling up antenatal genetic services within the free health system might be better suited to the Sri Lankan structural and social context. Conclusions: Scaling up antenatal genetic services within the public health system is not feasible in the current financial, legal, and human resource context. Yet current availability and utilization patterns contribute to regional and economic disparities, suggesting that stasis will not bring continued improvements in maternal and child health. More information on the burden of congenital disorders is necessary to fully understand if and how antenatal genetic service availability should be increased in Sri Lanka, but even before that information is gathered, examination of policies for patient referral, termination of pregnancy, and government support for individuals with genetic disease are steps that might bring extend improvements and reduce disparity in maternal and child health.
Resumo:
BACKGROUND: Individuals without prior immunity to a vaccine vector may be more sensitive to reactions following injection, but may also show optimal immune responses to vaccine antigens. To assess safety and maximal tolerated dose of an adenoviral vaccine vector in volunteers without prior immunity, we evaluated a recombinant replication-defective adenovirus type 5 (rAd5) vaccine expressing HIV-1 Gag, Pol, and multiclade Env proteins, VRC-HIVADV014-00-VP, in a randomized, double-blind, dose-escalation, multicenter trial (HVTN study 054) in HIV-1-seronegative participants without detectable neutralizing antibodies (nAb) to the vector. As secondary outcomes, we also assessed T-cell and antibody responses. METHODOLOGY/PRINCIPAL FINDINGS: Volunteers received one dose of vaccine at either 10(10) or 10(11) adenovector particle units, or placebo. T-cell responses were measured against pools of global potential T-cell epitope peptides. HIV-1 binding and neutralizing antibodies were assessed. Systemic reactogenicity was greater at the higher dose, but the vaccine was well tolerated at both doses. Although no HIV infections occurred, commercial diagnostic assays were positive in 87% of vaccinees one year after vaccination. More than 85% of vaccinees developed HIV-1-specific T-cell responses detected by IFN-γ ELISpot and ICS assays at day 28. T-cell responses were: CD8-biased; evenly distributed across the three HIV-1 antigens; not substantially increased at the higher dose; and detected at similar frequencies one year following injection. The vaccine induced binding antibodies against at least one HIV-1 Env antigen in all recipients. CONCLUSIONS/SIGNIFICANCE: This vaccine appeared safe and was highly immunogenic following a single dose in human volunteers without prior nAb against the vector. TRIAL REGISTRATION: ClinicalTrials.gov NCT00119873.
Resumo:
Diagnosis and treatment of comorbid neuropsychiatric illness is often a secondary focus of treatment in individuals with autism spectrum disorder (ASD), given that substantial impairment may be caused by core symptoms of ASD itself. However, psychiatric comorbidities, including depressive disorders, are common and frequently result in additional functional impairment, treatment costs, and burden on caregivers. Clinicians may struggle to appropriately diagnose depression in ASD due to communication deficits, atypical presentation of depression in ASD, and lack of standardized diagnostic tools. Specific risk and resilience factors for depression in ASD across the lifespan, including level of functioning, age, family history, and coping style, have been suggested, but require further study. Treatment with medications or psychotherapy may be beneficial, though more research is required to establish guidelines for management of symptoms. This review will describe typical presentations of depression in individuals with ASD, review current information on the prevalence, assessment, and treatment of comorbid depression in individuals with ASD, and identify important research gaps.
Resumo:
X-ray mammography has been the gold standard for breast imaging for decades, despite the significant limitations posed by the two dimensional (2D) image acquisitions. Difficulty in diagnosing lesions close to the chest wall and axilla, high amount of structural overlap and patient discomfort due to compression are only some of these limitations. To overcome these drawbacks, three dimensional (3D) breast imaging modalities have been developed including dual modality single photon emission computed tomography (SPECT) and computed tomography (CT) systems. This thesis focuses on the development and integration of the next generation of such a device for dedicated breast imaging. The goals of this dissertation work are to: [1] understand and characterize any effects of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without interference from the other. Such a system would overcome artifacts resulting from incompletely sampled divergent cone beam imaging schemes and allow imaging closer to the chest wall, which other systems currently under research and development elsewhere cannot achieve.
The dependence of x-ray scatter radiation on object shape, size, material composition and the CT acquisition trajectory, was investigated with a well-established beam stop array (BSA) scatter correction method. While the 2D scatter to primary ratio (SPR) was the main metric used to characterize total system scatter, a new metric called ‘normalized scatter contribution’ was developed to compare the results of scatter correction on 3D reconstructed volumes. Scatter estimation studies were undertaken with a sinusoidal saddle (±15° polar tilt) orbit and a traditional circular (AZOR) orbit. Clinical studies to acquire data for scatter correction were used to evaluate the 2D SPR on a small set of patients scanned with the AZOR orbit. Clinical SPR results showed clear dependence of scatter on breast composition and glandular tissue distribution, otherwise consistent with the overall phantom-based size and density measurements. Additionally, SPR dependence was also observed on the acquisition trajectory where 2D scatter increased with an increase in the polar tilt angle of the system.
The dose delivered by any imaging system is of primary importance from the patient’s point of view, and therefore trajectory related differences in the dose distribution in a target volume were evaluated. Monte Carlo simulations as well as physical measurements using radiochromic film were undertaken using saddle and AZOR orbits. Results illustrated that both orbits deliver comparable dose to the target volume, and only slightly differ in distribution within the volume. Simulations and measurements showed similar results, and all measured dose values were within the standard screening mammography-specific, 6 mGy dose limit, which is used as a benchmark for dose comparisons.
Hounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is very important, especially when using non-traditional trajectories. Uniform phantoms filled with various uniform density fluids were used to investigate differences in HU accuracy between saddle and AZOR orbits. Results illustrate the considerably better performance of the saddle orbit, especially close to the chest and nipple region of what would clinically be a pedant breast volume. The AZOR orbit causes shading artifacts near the nipple, due to insufficient sampling, rendering a major portion of the scanned phantom unusable, whereas the saddle orbit performs exceptionally well and provides a tighter distribution of HU values in reconstructed volumes.
Finally, the third generation, fully-suspended SPECT-CT system was designed in and developed in our lab. A novel mechanical method using a linear motor was developed for tilting the CT system. A new x-ray source and a custom made 40 x 30 cm2 detector were integrated on to this system. The SPECT system was nested, in the center of the gantry, orthogonal to the CT source-detector pair. The SPECT system tilts on a goniometer, and the newly developed CT tilting mechanism allows ±15° maximum polar tilting of the CT system. The entire gantry is mounted on a rotation stage, allowing complex arbitrary trajectories for each system, without interference from the other, while having a common field of view. This hybrid system shows potential to be used clinically as a diagnostic tool for dedicated breast imaging.
Outcomes and Predictors of Mortality in Neurosurgical Patients at Mbarara Regional Referral Hospital
Resumo:
Background:
Knowing the scope of neurosurgical disease at Mbarara Hospital is critical for infrastructure planning, education and training. In this study, we aim to evaluate the neurosurgical outcomes and identify predictors of mortality in order to potentiate platforms for more effective interventions and inform future research efforts at Mbarara Hospital.
Methods:
This is retrospective chart review including patients of all ages with a neurosurgical disease or injury presenting to Mbarara Regional Referral Hospital (MRRH) between January 2012 to September 2015. Descriptive statistics were presented. A univariate analysis was used to obtain the odds ratios of mortality and 95% confidence intervals. Predictors of mortality were determined using multivariate logistic regression model.
Results:
A total of 1876 charts were reviewed. Of these, 1854 (had complete data and were?) were included in the analysis. The overall mortality rate was 12.75%; the mortality rates among all persons who underwent a neurosurgical procedure was 9.72%, and was 13.68% among those who did not undergo a neurosurgical procedure. Over 50% of patients were between 19 and 40 years old and the majority of were males (76.10%). The overall median length of stay was 5 days. Of all neurosurgical admissions, 87% were trauma patients. In comparison to mild head injury, closed head injury and intracranial hematoma patients were 5 (95% CI: 3.77, 8.26) and 2.5 times (95% CI: 1.64,3.98) more likely to die respectively. Procedure and diagnostic imaging were independent negative predictors of mortality (P <0.05). While age, ICU admission, admission GCS were positive predictors of mortality (P <0.05).
Conclusions:
The majority of hospital admissions were TBI patients, with RTIs being the most common mechanism of injury. Age, ICU admission, admission GCS, diagnostic imaging and undergoing surgery were independent predictors of mortality. Going forward, further exploration of patient characteristics is necessary to fully describe mortality outcomes and implement resource appropriate interventions that ultimately improve morbidity and mortality.