2 resultados para Electric insulators and insulation Deterioration
em Duke University
Resumo:
This dissertation consists of two independent musical compositions and an article detailing the process of the design and assembly of an electric guitar with particular emphasis on the carefully curated suite of embedded effects.
The first piece, 'Phase Locked Loop and Modulo Games' is scored for electric guitar and a single echo of equal volume less than a beat away. One could think of the piece as a 15 minute canon at the unison at the dotted eighth note (or at times the quarter or triplet-quarter), however the compositional motivation is more about weaving a composite texture between the guitar and its echo that is, while in theory extremely contrapuntal, in actuality is simply a single [superhuman] melodic line.
The second piece, 'The Dogma Loops' picks up a few compositional threads left by ‘Phase Locked Loop’ and weaves them into an entirely new tapestry. 'Phase Locked Loop' is motivated by the creation of a complex musical composite that is for the most part electronically transparent. 'The Dogma Loops' questions that same notion of composite electronic complexity by essentially asking a question: "what are the inputs to an interactive electronic system that create the most complex outputs via the simplest musical means possible?"
'The Dogma Loops' is scored for Electric Guitar (doubling on Ukulele), Violin and Violoncello. All of the principal instruments require an electronic pickup (except the Uke). The work is in three sections played attacca; [Automation Games], [Point of Origin] and [Cloning Vectors].
The third and final component of the document is the article 'Finding Ibrida.' This article details the process of the design and assembly of an electric guitar with integrated effects, while also providing the deeper context (conceptual and technical) which motivated the efforts and informed the challenges to hybridize the various technologies (tubes, transistors, digital effects and a microcontroller subsystem). The project was motivated by a desire for rigorous technical and hands-on engagement with analog signal processing as applied to the electric guitar. ‘Finding Ibrida’ explores sound, some myths and lore of guitar tech and the history of electric guitar distortion and its culture of sonic exploration.
Resumo:
Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient’s medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method.
Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three approaches were applied in this research for dosimetric evaluation on CT images with severe metal artefacts. The first part of the research used a water phantom with four iodine syringes. Two sets of plans, multi-arc plans and single-arc plans, using the Volumetric Modulated Arc therapy (VMAT) technique were designed to avoid or minimize influences from high-density objects. The second part of the research used projection-based MAR Algorithm and the Dual-Energy Method. Calculated Doses (Mean, Minimum, and Maximum Doses) to the planning treatment volume (PTV) were compared and homogeneity index (HI) calculated.
Results: (1) Without the GSI-based MAR application, a percent error between mean dose and the absolute dose ranging from 3.4-5.7% per fraction was observed. In contrast, the error was decreased to a range of 0.09-2.3% per fraction with the GSI-based MAR algorithm. There was a percent difference ranging from 1.7-4.2% per fraction between with and without using the GSI-based MAR algorithm. (2) A range of 0.1-3.2% difference was observed for the maximum dose values, 1.5-10.4% for minimum dose difference, and 1.4-1.7% difference on the mean doses. Homogeneity indexes (HI) ranging from 0.068-0.065 for dual-energy method and 0.063-0.141 with projection-based MAR algorithm were also calculated.
Conclusion: (1) Percent error without using the GSI-based MAR algorithm may deviate as high as 5.7%. This error invalidates the goal of Radiation Therapy to provide a more precise treatment. Thus, GSI-based MAR algorithm was desirable due to its better dose calculation accuracy. (2) Based on direct numerical observation, there was no apparent deviation between the mean doses of different techniques but deviation was evident on the maximum and minimum doses. The HI for the dual-energy method almost achieved the desirable null values. In conclusion, the Dual-Energy method gave better dose calculation accuracy to the planning treatment volume (PTV) for images with metal artefacts than with or without GE MAR Algorithm.