5 resultados para Dental Bonding, Chemically-Cured

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

While the Stokes-Einstein (SE) equation predicts that the diffusion coefficient of a solute will be inversely proportional to the viscosity of the solvent, this relation is commonly known to fail for solutes, which are the same size or smaller than the solvent. Multiple researchers have reported that for small solutes, the diffusion coefficient is inversely proportional to the viscosity to a fractional power, and that solutes actually diffuse faster than SE predicts. For other solvent systems, attractive solute-solvent interactions, such as hydrogen bonding, are known to retard the diffusion of a solute. Some researchers have interpreted the slower diffusion due to hydrogen bonding as resulting from the effective diffusion of a larger complex of a solute and solvent molecules. We have developed and used a novel micropipette technique, which can form and hold a single microdroplet of water while it dissolves in a diffusion controlled environment into the solvent. This method has been used to examine the diffusion of water in both n-alkanes and n-alcohols. It was found that the polar solute water, diffusing in a solvent with which it cannot hydrogen bond, closely resembles small nonpolar solutes such as xenon and krypton diffusing in n-alkanes, with diffusion coefficients ranging from 12.5x10(-5) cm(2)/s for water in n-pentane to 1.15x10(-5) cm(2)/s for water in hexadecane. Diffusion coefficients were found to be inversely proportional to viscosity to a fractional power, and diffusion coefficients were faster than SE predicts. For water diffusing in a solvent (n-alcohols) with which it can hydrogen bond, diffusion coefficient values ranged from 1.75x10(-5) cm(2)/s in n-methanol to 0.364x10(-5) cm(2)/s in n-octanol, and diffusion was slower than an alkane of corresponding viscosity. We find no evidence for solute-solvent complex diffusion. Rather, it is possible that the small solute water may be retarded by relatively longer residence times (compared to non-H-bonding solvents) as it moves through the liquid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paleoprimatologists depend on relationships between form and function of teeth to reconstruct the diets of fossil species. Most of this work has been limited to studies of unworn teeth. A new approach, dental topographic analysis, allows the characterization and comparison of worn primate teeth. Variably worn museum specimens have been used to construct species-specific wear sequences so that measurements can be compared by wear stage among taxa with known differences in diet. This assumes that individuals in a species tend to wear their molar teeth in similar ways, a supposition that has yet to be tested. Here we evaluate this assumption with a longitudinal study of changes in tooth form over time in primates. Fourteen individual mantled howling monkeys (Alouatta palliata) were captured and then recaptured after 2, 4, and 7 years when possible at Hacienda La Pacifica in Costa Rica between 1989-1999. Dental impressions were taken each time, and molar casts were produced and analyzed using dental topographic analysis. Results showed consistent decreases in crown slope and occlusal relief. In contrast, crown angularity, a measure of surface jaggedness, remained fairly constant except with extreme wear. There were no evident differences between specimens collected in different microhabitats. These results suggest that different individual mantled howling monkeys wear their teeth down in similar ways, evidently following a species-specific wear sequence. Dental topographic analysis may therefore be used to compare morphology among similarly worn individuals from different species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One problem with dental microwear analyses of museum material is that investigators can never be sure of the diets of the animals in question. An obvious solution to this problem is to work with live animals. Recent work with laboratory primates has shown that high resolution dental impressions can be obtained from live animals. The purpose of this study was to use similar methods to begin to document rates and patterns of dental microwear for primates in the wild. Thirty-three Alouatta palliata were captured during the wet season at Hacienda La Pacifica near Canas, Costa Rica. Dental impressions were taken and epoxy casts of the teeth were prepared using the methods of Teaford and Oyen (1989a). Scanning electron micrographs were taken of the left mandibular second molars at magnifications of 200x and 500x. Lower magnification images were used to calculate rates of wear, and higher magnification images were used to measure the size and shape of microwear features. Results indicate that, while basic patterns of dental microwear are similar in museum samples and samples of live, wild-trapped animals of the same species, ecological differences between collection locales may lead to significant intraspecific differences in dental microwear. More importantly, rates of microwear provide the first direct evidence of differences in molar use between monkeys and humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental microwear researchers consider exogenous grit or dust to be an important cause of microscopic wear on primate teeth. No study to date has examined the accumulation of such abrasives on foods eaten by primates in the forest. This investigation introduces a method to collect dust at various heights in the canopy. Results from dust collection studies conducted at the primate research stations at Ketambe in Indonesia, and Hacienda La Pacifica in Costa Rica indicate that 1) grit collects throughout the canopy in both open country and tropical rain forest environments; and 2) the sizes and concentrations of dust particles accumulated over a fixed period of time differ depending on site location and season of investigation. These results may hold important implications for the interpretation of microwear on primate teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

© 2015 Elsevier Ltd. All rights reserved.Laboratory tests on microscale are reported in which millimeter-sized amorphous silica cubes were kept highly compressed in a liquid environment of de-ionized water solutions with different silica ion concentrations for up to four weeks. Such an arrangement simulates an early evolution of bonds between two sand grains stressed in situ. In-house designed Grain Indenter-Puller apparatus allowed measuring strength of such contacts after 3-4 weeks. Observations reported for the first time confirm a long-existing hypothesis that a stressed contact with microcracks generates silica polymers, forming a bonding structure between the grains on a timescale in the order of a few weeks. Such structure exhibits intergranular tensile force at failure of 1-1.5 mN when aged in solutions containing silica ion concentrations of 200-to 500-ppm. The magnitude of such intergranular force is 2-3 times greater than that of water capillary force between the same grains.