4 resultados para Decompression, Surgical
em Duke University
Resumo:
OBJECTIVE: To determine the epidemiological characteristics of postoperative invasive Staphylococcus aureus infection following 4 types of major surgical procedures.design. Retrospective cohort study. SETTING: Eleven hospitals (9 community hospitals and 2 tertiary care hospitals) in North Carolina and Virginia. PATIENTS: Adults undergoing orthopedic, neurosurgical, cardiothoracic, and plastic surgical procedures. METHODS: We used previously validated, prospectively collected surgical surveillance data for surgical site infection and microbiological data for bloodstream infection. The study period was 2003 through 2006. We defined invasive S. aureus infection as either nonsuperficial incisional surgical site infection or bloodstream infection. Nonparametric bootstrapping was used to generate 95% confidence intervals (CIs). P values were generated using the Pearson chi2 test, Student t test, or Wilcoxon rank-sum test, as appropriate. RESULTS: In total, 81,267 patients underwent 96,455 procedures during the study period. The overall incidence of invasive S. aureus infection was 0.47 infections per 100 procedures (95% CI, 0.43-0.52); 227 (51%) of 446 infections were due to methicillin-resistant S.aureus. Invasive S. aureus infection was more common after cardiothoracic procedures (incidence, 0.79 infections per 100 procedures [95%CI, 0.62-0.97]) than after orthopedic procedures (0.37 infections per 100 procedures [95% CI, 0.32-0.42]), neurosurgical procedures (0.62 infections per 100 procedures [95% CI, 0.53-0.72]), or plastic surgical procedures (0.32 infections per 100 procedures [95% CI, 0.17-0.47]) (P < .001). Similarly, S. aureus bloodstream infection was most common after cardiothoracic procedures (incidence, 0.57 infections per 100 procedures [95% CI, 0.43-0.72]; P < .001, compared with other procedure types), comprising almost three-quarters of the invasive S. aureus infections after these procedures. The highest rate of surgical site infection was observed after neurosurgical procedures (incidence, 0.50 infections per 100 procedures [95% CI, 0.42-0.59]; P < .001, compared with other procedure types), comprising 80% of invasive S.aureus infections after these procedures. CONCLUSION: The frequency and type of postoperative invasive S. aureus infection varied significantly across procedure types. The highest risk procedures, such as cardiothoracic procedures, should be targeted for ongoing preventative interventions.
Resumo:
This study intends to validate the sensitivity and specificity of coded aperture coherent scatter spectral imaging (CACSSI) by comparison to clinical histological preparation and pathologic analysis methods currently used for the differentiation of normal and neoplastic breast tissues. A composite overlay of the CACSSI rendered image and pathologist interpreted, stained sections validate the ability of coherent scatter imaging to differentiate cancerous tissues from normal, healthy breast structures ex-vivo. Via comparison to the pathologist annotated slides, the CACSSI system may be further optimized to maximized sensitivity and specificity for differentiation of breast carcinomas.
Resumo:
OBJECTIVE To use a unique multicomponent administrative data set assembled at a large academic teaching hospital to examine the risk of percutaneous blood and body fluid (BBF) exposures occurring in operating rooms. DESIGN A 10-year retrospective cohort design. SETTING A single large academic teaching hospital. PARTICIPANTS All surgical procedures (n=333,073) performed in 2001-2010 as well as 2,113 reported BBF exposures were analyzed. METHODS Crude exposure rates were calculated; Poisson regression was used to analyze risk factors and account for procedure duration. BBF exposures involving suture needles were examined separately from those involving other device types to examine possible differences in risk factors. RESULTS The overall rate of reported BBF exposures was 6.3 per 1,000 surgical procedures (2.9 per 1,000 surgical hours). BBF exposure rates increased with estimated patient blood loss (17.7 exposures per 1,000 procedures with 501-1,000 cc blood loss and 26.4 exposures per 1,000 procedures with >1,000 cc blood loss), number of personnel working in the surgical field during the procedure (34.4 exposures per 1,000 procedures having ≥15 personnel ever in the field), and procedure duration (14.3 exposures per 1,000 procedures lasting 4 to <6 hours, 27.1 exposures per 1,000 procedures lasting ≥6 hours). Regression results showed associations were generally stronger for suture needle-related exposures. CONCLUSIONS Results largely support other studies found in the literature. However, additional research should investigate differences in risk factors for BBF exposures associated with suture needles and those associated with all other device types. Infect. Control Hosp. Epidemiol. 2015;37(1):80-87.
Resumo:
The work presented in this dissertation is focused on applying engineering methods to develop and explore probabilistic survival models for the prediction of decompression sickness in US NAVY divers. Mathematical modeling, computational model development, and numerical optimization techniques were employed to formulate and evaluate the predictive quality of models fitted to empirical data. In Chapters 1 and 2 we present general background information relevant to the development of probabilistic models applied to predicting the incidence of decompression sickness. The remainder of the dissertation introduces techniques developed in an effort to improve the predictive quality of probabilistic decompression models and to reduce the difficulty of model parameter optimization.
The first project explored seventeen variations of the hazard function using a well-perfused parallel compartment model. Models were parametrically optimized using the maximum likelihood technique. Model performance was evaluated using both classical statistical methods and model selection techniques based on information theory. Optimized model parameters were overall similar to those of previously published Results indicated that a novel hazard function definition that included both ambient pressure scaling and individually fitted compartment exponent scaling terms.
We developed ten pharmacokinetic compartmental models that included explicit delay mechanics to determine if predictive quality could be improved through the inclusion of material transfer lags. A fitted discrete delay parameter augmented the inflow to the compartment systems from the environment. Based on the observation that symptoms are often reported after risk accumulation begins for many of our models, we hypothesized that the inclusion of delays might improve correlation between the model predictions and observed data. Model selection techniques identified two models as having the best overall performance, but comparison to the best performing model without delay and model selection using our best identified no delay pharmacokinetic model both indicated that the delay mechanism was not statistically justified and did not substantially improve model predictions.
Our final investigation explored parameter bounding techniques to identify parameter regions for which statistical model failure will not occur. When a model predicts a no probability of a diver experiencing decompression sickness for an exposure that is known to produce symptoms, statistical model failure occurs. Using a metric related to the instantaneous risk, we successfully identify regions where model failure will not occur and identify the boundaries of the region using a root bounding technique. Several models are used to demonstrate the techniques, which may be employed to reduce the difficulty of model optimization for future investigations.