2 resultados para Dahl, Roal

em Duke University


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research examines how the body type of consumers affects the food consumption of other consumers around them. We find that consumers anchor on the quantities others around them select but that these portions are adjusted according to the body type of the other consumer. We find that people choose a larger portion following another consumer who first selects a large quantity but that this portion is significantly smaller if the other is obese than if she is thin. We also find that the adjustment is more pronounced for consumers who are low in appearance self-esteem and that it is attenuated under cognitive load. © 2009 by Journal of Consumer Research, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our long-term goal is the detection and characterization of vulnerable plaque in the coronary arteries of the heart using intravascular ultrasound (IVUS) catheters. Vulnerable plaque, characterized by a thin fibrous cap and a soft, lipid-rich necrotic core is a precursor to heart attack and stroke. Early detection of such plaques may potentially alter the course of treatment of the patient to prevent ischemic events. We have previously described the characterization of carotid plaques using external linear arrays operating at 9 MHz. In addition, we previously modified circular array IVUS catheters by short-circuiting several neighboring elements to produce fixed beamwidths for intravascular hyperthermia applications. In this paper, we modified Volcano Visions 8.2 French, 9 MHz catheters and Volcano Platinum 3.5 French, 20 MHz catheters by short-circuiting portions of the array for acoustic radiation force impulse imaging (ARFI) applications. The catheters had an effective transmit aperture size of 2 mm and 1.5 mm, respectively. The catheters were connected to a Verasonics scanner and driven with pushing pulses of 180 V p-p to acquire ARFI data from a soft gel phantom with a Young's modulus of 2.9 kPa. The dynamic response of the tissue-mimicking material demonstrates a typical ARFI motion of 1 to 2 microns as the gel phantom displaces away and recovers back to its normal position. The hardware modifications applied to our IVUS catheters mimic potential beamforming modifications that could be implemented on IVUS scanners. Our results demonstrate that the generation of radiation force from IVUS catheters and the development of intravascular ARFI may be feasible.