2 resultados para Closure flexibility

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

When recalling autobiographical memories, individuals often experience visual images associated with the event. These images can be constructed from two different perspectives: first person, in which the event is visualized from the viewpoint experienced at encoding, or third person, in which the event is visualized from an external vantage point. Using a novel technique to measure visual perspective, we examined where the external vantage point is situated in third-person images. Individuals in two studies were asked to recall either 10 or 15 events from their lives and describe the perspectives they experienced. Wide variation in spatial locations was observed within third-person perspectives, with the location of these perspectives relating to the event being recalled. Results suggest remembering from an external viewpoint may be more common than previous studies have demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The prevalence of residual shunt in patients after device closure of atrial septal defect and its impact on long-term outcome has not been previously defined. METHODS: From a prospective, single-institution registry of 408 patients, we selected individuals with agitated saline studies performed 1 year after closure. Baseline echocardiographic, invasive hemodynamic, and comorbidity data were compared to identify contributors to residual shunt. Survival was determined by review of the medical records and the Social Security Death Index. Survival analysis according to shunt included construction of Kaplan-Meier curves and Cox proportional hazards modeling. RESULTS: Among 213 analyzed patients, 27% were men and age at repair was 47 ± 17 years. Thirty patients (14%) had residual shunt at 1 year. Residual shunt was more common with Helex (22%) and CardioSEAL/STARFlex (40%) occluder devices than Amplatzer devices (9%; P = .005). Residual shunts were more common in whites (79% vs 46%, P = .004). At 7.3 ± 3.3 years of follow-up, 13 (6%) of patients had died, including 8 (5%) with Amplatzer, 5 (25%) with CardioSEAL/STARFlex, and 0 with Helex devices. Patients with residual shunting had a higher hazard of death (20% vs 4%, P = .001; hazard ratio 4.95 [1.59-14.90]). In an exploratory multivariable analysis, residual shunting, age, hypertension, coronary artery disease, and diastolic dysfunction were associated with death. CONCLUSIONS: Residual shunt after atrial septal defect device closure is common and adversely impacts long-term survival.