8 resultados para Block triangulation with additional parameters

em Duke University


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is an investigation into collimator designs for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact neutron imaging system that can be implemented in a hospital. The envisioned application is for a spectroscopic imaging technique called neutron stimulated emission computed tomography (NSECT).

Previous NSECT studies have been performed using a Van-de-Graaff accelerator at the Triangle Universities Nuclear Laboratory (TUNL) in Duke University. This facility has provided invaluable research into the development of NSECT. To transition the current imaging method into a clinically feasible system, there is a need for a high-intensity fast neutron source that can produce collimated beams. The DD neutron generator from Adelphi Technologies Inc. is being explored as a possible candidate to provide the uncollimated neutrons. This DD generator is a compact source that produces 2.5 MeV fast neutrons with intensities of 1012 n/s (4π). The neutron energy is sufficient to excite most isotopes of interest in the body with the exception of carbon and oxygen. However, a special collimator is needed to collimate the 4π neutron emission into a narrow beam. This work describes the development and evaluation of a series of collimator designs to collimate the DD generator for narrow beams suitable for NSECT imaging.

A neutron collimator made of high-density polyethylene (HDPE) and lead was modeled and simulated using the GEANT4 toolkit. The collimator was designed as a 52 x 52 x 52 cm3 HDPE block coupled with 1 cm lead shielding. Non-tapering (cylindrical) and tapering (conical) opening designs were modeled into the collimator to permit passage of neutrons. The shape, size, and geometry of the aperture were varied to assess the effects on the collimated neutron beam. Parameters varied were: inlet diameter (1-5 cm), outlet diameter (1-5 cm), aperture diameter (0.5-1.5 cm), and aperture placement (13-39 cm). For each combination of collimator parameters, the spatial and energy distributions of neutrons and gammas were tracked and analyzed to determine three performance parameters: neutron beam-width, primary neutron flux, and the output quality. To evaluate these parameters, the simulated neutron beams are then regenerated for a NSECT breast scan. Scan involved a realistic breast lesion implanted into an anthropomorphic female phantom.

This work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-collimated neutron beam that can be used for NSECT breast imaging. The aperture diameter showed a strong correlation to the beam-width, where the collimated neutron beam-width was about 10% larger than the physical aperture diameter. In addition, a collimator opening consisting of a tapering inlet and cylindrical outlet allowed greater neutron throughput when compared to a simple cylindrical opening. The tapering inlet design can allow additional neutron throughput when the neck is placed farther from the source. On the other hand, the tapering designs also decrease output quality (i.e. increase in stray neutrons outside the primary collimated beam). All collimators are cataloged in measures of beam-width, neutron flux, and output quality. For a particular NSECT application, an optimal choice should be based on the collimator specifications listed in this work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The successful design of biomaterial scaffolds for articular cartilage tissue engineering requires an understanding of the impact of combinations of material formulation parameters on diverse and competing functional outcomes of biomaterial performance. This study sought to explore the use of a type of unsupervised artificial network, a self-organizing map, to identify relationships between scaffold formulation parameters (crosslink density, molecular weight, and concentration) and 11 such outcomes (including mechanical properties, matrix accumulation, metabolite usage and production, and histological appearance) for scaffolds formed from crosslinked elastin-like polypeptide (ELP) hydrogels. The artificial neural network recognized patterns in functional outcomes and provided a set of relationships between ELP formulation parameters and measured outcomes. Mapping resulted in the best mean separation amongst neurons for mechanical properties and pointed to crosslink density as the strongest predictor of most outcomes, followed by ELP concentration. The map also grouped formulations together that simultaneously resulted in the highest values for matrix production, greatest changes in metabolite consumption or production, and highest histological scores, indicating that the network was able to recognize patterns amongst diverse measurement outcomes. These results demonstrated the utility of artificial neural network tools for recognizing relationships in systems with competing parameters, toward the goal of optimizing and accelerating the design of biomaterial scaffolds for articular cartilage tissue engineering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Monogamy, together with abstinence, partner reduction, and condom use, is widely advocated as a key behavioral strategy to prevent HIV infection in sub-Saharan Africa. We examined the association between the number of sexual partners and the risk of HIV seropositivity among men and women presenting for HIV voluntary counseling and testing (VCT) in northern Tanzania. METHODOLOGY/ PRINCIPAL FINDINGS: Clients presenting for HIV VCT at a community-based AIDS service organization in Moshi, Tanzania were surveyed between November 2003 and December 2007. Data on sociodemographic characteristics, reasons for testing, sexual behaviors, and symptoms were collected. Men and women were categorized by number of lifetime sexual partners, and rates of seropositivity were reported by category. Factors associated with HIV seropositivity among monogamous males and females were identified by a multivariate logistic regression model. Of 6,549 clients, 3,607 (55%) were female, and the median age was 30 years (IQR 24-40). 939 (25%) females and 293 (10%) males (p<0.0001) were HIV seropositive. Among 1,244 (34%) monogamous females and 423 (14%) monogamous males, the risk of HIV infection was 19% and 4%, respectively (p<0.0001). The risk increased monotonically with additional partners up to 45% (p<0.001) and 15% (p<0.001) for women and men, respectively with 5 or more partners. In multivariate analysis, HIV seropositivity among monogamous women was most strongly associated with age (p<0.0001), lower education (p<0.004), and reporting a partner with other partners (p = 0.015). Only age was a significant risk factor for monogamous men (p = 0.0004). INTERPRETATION: Among women presenting for VCT, the number of partners is strongly associated with rates of seropositivity; however, even women reporting lifetime monogamy have a high risk for HIV infection. Partner reduction should be coupled with efforts to place tools in the hands of sexually active women to reduce their risk of contracting HIV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seminal work by Weitzman (1974) revealed prices are preferred to quantities when marginal benefits are relatively flat compared to marginal costs. We extend this comparison to indexed policies, where quantities are proportional to an index, such as output. We find that policy preferences hinge on additional parameters describing the first and second moments of the index and the ex post optimal quantity level. When the ratio of these variables' coefficients of variation divided by their correlation is less than approximately two, indexed quantities are preferred to fixed quantities. A slightly more complex condition determines when indexed quantities are preferred to prices. Applied to climate change policy, we find that the range of variation and correlation in country-level carbon dioxide emissions and GDP suggests the ranking of an emissions intensity cap (indexed to GDP) compared to a fixed emission cap is not uniform across countries; neither policy clearly dominates the other.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Functional MRI (fMRI) can detect blood oxygenation level dependent (BOLD) hemodynamic responses secondary to neuronal activity. The most commonly used method for detecting fMRI signals is the gradient-echo echo-planar imaging (EPI) technique because of its sensitivity and speed. However, it is generally believed that a significant portion of these signals arises from large veins, with additional contribution from the capillaries and parenchyma. Early experiments using diffusion-weighted gradient-echo EPI have suggested that intra-voxel incoherent motion (IVIM) weighting inherent in the sequence can selectively attenuate contributions from different vessels based on the differences in the mobility of the blood within them. In the present study, we used similar approach to characterize the apparent diffusion coefficient (ADC) distribution within the activated areas of BOLD contrast. It is shown that the voxel values of the ADCs obtained from this technique can infer various vascular contributions to the BOLD signal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

De novo donor-specific antibody (DSA) after organ transplantation promotes antibody-mediated rejection (AMR) and causes late graft loss. Previously, we demonstrated that depletion using anti-CD3 immunotoxin combined with tacrolimus and alefacept (AMR regimen) reliably induced early DSA production with AMR in a nonhuman primate kidney transplant model. Five animals were assigned as positive AMR controls, four received additional belatacept and four received additional anti-CD40 mAb (2C10R4). Notably, production of early de novo DSA was completely attenuated with additional belatacept or 2C10R4 treatment. In accordance with this, while positive controls experienced a decrease in peripheral IgM(+) B cells, bela- and 2C10R4-added groups maintained a predominant population of IgM(+) B cells, potentially indicating decreased isotype switching. Central memory T cells (CD4(+) CD28(+) CD95(+)) as well as PD-1(hi) CD4(+) T cells were decreased in both bela-added and 2C10R4-added groups. In analyzing germinal center (GC) reactions in situ, lymph nodes further revealed a reduction of B cell clonal expansion, GC-follicular helper T (Tfh) cells, and IL-21 production inside GCs with additional belatacept or 2C10R4 treatment. Here we provide evidence that belatacept and 2C10R4 selectively suppresses the humoral response via regulating Tfh cells and prevents AMR in this nonhuman primate model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The skeleton is of fundamental importance in research in comparative vertebrate morphology, paleontology, biomechanics, developmental biology, and systematics. Motivated by research questions that require computational access to and comparative reasoning across the diverse skeletal phenotypes of vertebrates, we developed a module of anatomical concepts for the skeletal system, the Vertebrate Skeletal Anatomy Ontology (VSAO), to accommodate and unify the existing skeletal terminologies for the species-specific (mouse, the frog Xenopus, zebrafish) and multispecies (teleost, amphibian) vertebrate anatomy ontologies. Previous differences between these terminologies prevented even simple queries across databases pertaining to vertebrate morphology. This module of upper-level and specific skeletal terms currently includes 223 defined terms and 179 synonyms that integrate skeletal cells, tissues, biological processes, organs (skeletal elements such as bones and cartilages), and subdivisions of the skeletal system. The VSAO is designed to integrate with other ontologies, including the Common Anatomy Reference Ontology (CARO), Gene Ontology (GO), Uberon, and Cell Ontology (CL), and it is freely available to the community to be updated with additional terms required for research. Its structure accommodates anatomical variation among vertebrate species in development, structure, and composition. Annotation of diverse vertebrate phenotypes with this ontology will enable novel inquiries across the full spectrum of phenotypic diversity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Office-based percutaneous revision of a testicular prosthesis has never been reported. A patient received a testicular prosthesis but was dissatisfied with the firmness of the implant. In an office setting, the prosthesis was inflated with additional fluid via a percutaneous approach. Evaluated outcomes included patient satisfaction, prosthesis size, recovery time, and cost savings. The patient was satisfied, with no infection, leak, or complication after more than 1 year of follow-up, at significantly less cost than revision surgery. Percutaneous adjustment of testicular prosthesis fill-volume can be safe, inexpensive, and result in good patient satisfaction.