5 resultados para Binary Coded Decimal

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We apply a coded aperture snapshot spectral imager (CASSI) to fluorescence microscopy. CASSI records a two-dimensional (2D) spectrally filtered projection of a three-dimensional (3D) spectral data cube. We minimize a convex quadratic function with total variation (TV) constraints for data cube estimation from the 2D snapshot. We adapt the TV minimization algorithm for direct fluorescent bead identification from CASSI measurements by combining a priori knowledge of the spectra associated with each bead type. Our proposed method creates a 2D bead identity image. Simulated fluorescence CASSI measurements are used to evaluate the behavior of the algorithm. We also record real CASSI measurements of a ten bead type fluorescence scene and create a 2D bead identity map. A baseline image from filtered-array imaging system verifies CASSI's 2D bead identity map.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a comprehensive study of the binary systems of the platinum-group metals with the transition metals, using high-throughput first-principles calculations. These computations predict stability of new compounds in 28 binary systems where no compounds have been reported in the literature experimentally and a few dozen of as-yet unreported compounds in additional systems. Our calculations also identify stable structures at compound compositions that have been previously reported without detailed structural data and indicate that some experimentally reported compounds may actually be unstable at low temperatures. With these results, we construct enhanced structure maps for the binary alloys of platinum-group metals. These maps are much more complete, systematic, and predictive than those based on empirical results alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use mechanical translation of a coded aperture for code division multiple access compression of video. We discuss the compressed video's temporal resolution and present experimental results for reconstructions of > 10 frames of temporal data per coded snapshot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study intends to validate the sensitivity and specificity of coded aperture coherent scatter spectral imaging (CACSSI) by comparison to clinical histological preparation and pathologic analysis methods currently used for the differentiation of normal and neoplastic breast tissues. A composite overlay of the CACSSI rendered image and pathologist interpreted, stained sections validate the ability of coherent scatter imaging to differentiate cancerous tissues from normal, healthy breast structures ex-vivo. Via comparison to the pathologist annotated slides, the CACSSI system may be further optimized to maximized sensitivity and specificity for differentiation of breast carcinomas.