7 resultados para 1995_12071128 Optics-9

em Duke University


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-efficiency collection of photons emitted by a point source over a wide field of view (FoV) is crucial for many applications. Multiscale optics offer improved light collection by utilizing small optical components placed close to the optical source, while maintaining a wide FoV provided by conventional imaging optics. In this work, we demonstrate collection efficiency of 26% of photons emitted by a pointlike source using a micromirror fabricated in silicon with no significant decrease in collection efficiency over a 10 mm object space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We apply the transformation optical technique to modify or improve conventional refractive and gradient index optical imaging devices. In particular, when it is known that a detector will terminate the paths of rays over some surface, more freedom is available in the transformation approach, since the wave behavior over a large portion of the domain becomes unimportant. For the analyzed configurations, quasi-conformal and conformal coordinate transformations can be used, leading to simplified constitutive parameter distributions that, in some cases, can be realized with isotropic index; index-only media can be low-loss and have broad bandwidth. We apply a coordinate transformation to flatten a Maxwell fish-eye lens, forming a near-perfect relay lens; and also flatten the focal surface associated with a conventional refractive lens, such that the system exhibits an ultra-wide field-of-view with reduced aberration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a class of optical media based on adiabatically modulated, dielectric-only, and potentially extremely low-loss, photonic crystals (PC). The media we describe represent a generalization of the eikonal limit of transformation optics (TO). The basis of the concept is the possibility to fit some equal frequency surfaces of certain PCs with elliptic surfaces, allowing them to mimic the dispersion relation of light in anisotropic effective media. PC cloaks and other TO devices operating at visible wavelengths can be constructed from optically transparent substances such as glasses, whose attenuation coefficient can be as small as 10 dB/km, suggesting the TO design methodology can be applied to the development of optical devices not limited by the losses inherent to metal-based, passive metamaterials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study compared LDL, HDL, and VLDL subclasses in overweight or obese adults consuming either a reduced carbohydrate (RC) or reduced fat (RF) weight maintenance diet for 9 months following significant weight loss. METHODS: Thirty-five (21 RC; 14 RF) overweight or obese middle-aged adults completed a 1-year weight management clinic. Participants met weekly for the first six months and bi-weekly thereafter. Meetings included instruction for diet, physical activity, and behavior change related to weight management. Additionally, participants followed a liquid very low-energy diet of approximately 2092 kJ per day for the first three months of the study. Subsequently, participants followed a dietary plan for nine months that targeted a reduced percentage of carbohydrate (approximately 20%) or fat (approximately 30%) intake and an energy intake level calculated to maintain weight loss. Lipid subclasses using NMR spectroscopy were analyzed prior to weight loss and at multiple intervals during weight maintenance. RESULTS: Body weight change was not significantly different within or between groups during weight maintenance (p>0.05). The RC group showed significant increases in mean LDL size, large LDL, total HDL, large and small HDL, mean VLDL size, and large VLDL during weight maintenance while the RF group showed increases in total HDL, large and small HDL, total VLDL, and large, medium, and small VLDL (p<0.05). Group*time interactions were significant for large and medium VLDL (p>0.05). CONCLUSION: Some individual lipid subclasses improved in both dietary groups. Large and medium VLDL subclasses increased to a greater extent across weight maintenance in the RF group.